ASTM F856-1997(2004) Standard Practice for Mechanical Symbols Shipboard&8212 Heating Ventilation and Air Conditioning (HVAC)《加热、通风及空调符号》.pdf

上传人:progressking105 文档编号:537405 上传时间:2018-12-06 格式:PDF 页数:7 大小:111.05KB
下载 相关 举报
ASTM F856-1997(2004) Standard Practice for Mechanical Symbols Shipboard&8212 Heating Ventilation and Air Conditioning (HVAC)《加热、通风及空调符号》.pdf_第1页
第1页 / 共7页
ASTM F856-1997(2004) Standard Practice for Mechanical Symbols Shipboard&8212 Heating Ventilation and Air Conditioning (HVAC)《加热、通风及空调符号》.pdf_第2页
第2页 / 共7页
ASTM F856-1997(2004) Standard Practice for Mechanical Symbols Shipboard&8212 Heating Ventilation and Air Conditioning (HVAC)《加热、通风及空调符号》.pdf_第3页
第3页 / 共7页
ASTM F856-1997(2004) Standard Practice for Mechanical Symbols Shipboard&8212 Heating Ventilation and Air Conditioning (HVAC)《加热、通风及空调符号》.pdf_第4页
第4页 / 共7页
ASTM F856-1997(2004) Standard Practice for Mechanical Symbols Shipboard&8212 Heating Ventilation and Air Conditioning (HVAC)《加热、通风及空调符号》.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: F 856 97 (Reapproved 2004)An American National StandardStandard Practice forMechanical Symbols, ShipboardHeating, Ventilation, andAir Conditioning (HVAC)1This standard is issued under the fixed designation F 856; the number immediately following the designation indicates the year oforig

2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of D

3、efense.1. Scope1.1 This practice covers symbols used on heating, ventila-tion, and air conditioning (HVAC) detailed engineering draw-ings.1.2 These symbols may be useful on contract and prelimi-nary design drawings.2. Significance and Use2.1 When symbolic representation is required for an itemnot co

4、vered in this standard, the character of the symbol shallbe adequately identified and shall be subject to one interpreta-tion only. If necessary, a note shall be attached to the symbolfor further clarity.2.2 Symbolic representation does not require exact or scalelayouts of the actual system. Therefo

5、re, the symbols may beused in all views of the system layout.3. Abbreviations3.1 The abbreviations (for use only in this practice) aredefined as follows:AF = axial fan,AFD = automatic fire damper with manual override,BD = balance damper,CC = cooling coil,CCW = counter clockwise,CE = convection heate

6、r, electric,CF = centrifugal fan,CS = convection heater, steam,CW = clockwise,EH = turret heater electric,EP = duct preheater, electric,ER = duct reheater, electric,EU = electric unit heater,F = filter,FA = flame arrester,FCA = fan coil assembly,FCU = fan coil unit,G = grille,GC = gravity cooling co

7、il,H = humidistat, humidifier,L = louver,M = motor,MFD = manual fire damper,NE = natural exhaust,NS = natural supply,R = return air,RO = remote operated,SFD = solenoid fire damper,SP = preheater, steam,SR = reheater, steam,SU = steam unit heater,T = thermostat,TE = tempered air, electric,TS = temper

8、ed air, steam,U = undercut,UC = unit cooler,V = volume, volumetric, andVC = volume control.4. Illustrations4.1 Illustrations for HVAC symbols are given in Figs. 1-4.5. Keywords5.1 air conditioning; design symbols; engineering symbols;heating; HVAC; marine; ship; symbols; ventilation1This practice is

9、 under the jurisdiction of ASTM Committee F25 on Ships andMarine Technology and is the direct responsibility of Subcommittee F25.11 onMachinery and Piping Systems.Current edition approved May 1, 2004. Published May 2004. Originallyapproved in 1983. Last previous edition approved in 1997 as F 856 97.

10、1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NOTE 1“Class A is in reference to bulkhead classification as described in the Code of Federal Regulations, Title 46, Section 92.07-5. (Availablefrom Superintendent of Documents, U. S. G

11、overnment Printing Office, Washington, DC 20402.)FIG. 1 HVAC Symbols for Air Flow DuctsF 856 97 (2004)2FIG. 2 HVAC Symbols for Duct FittingsF 856 97 (2004)3FIG. 2 HVAC Symbols for Duct Fittings (continued)F 856 97 (2004)4NOTE 1This symbol is commonly referred to as a Breidert ventilator.FIG. 3 HVAC

12、Symbols for VentilatorsF 856 97 (2004)5NOTE 1This symbol is commonly referred to as a Gaylord hood.FIG. 4 HVAC Symbols for AppliancesF 856 97 (2004)6ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users

13、 of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every f

14、ive years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical

15、 committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).F 856 97 (2004)7

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1