1、Errata to ANSI/AW WA C200-12 Standard forSteel Water Pipe, 6 In. (150 mm) and Larger(August 2012)1. Add footnote 3 callout to Table 1, pg. 11, as follows:ASTM A139/A139M32. Change Sec. 4.11.3, page 21, to read:4.11.3 Straightness. The maximum deviation from a straight line, over the entire pipe leng
2、th, shall be 0.2 percent of the pipe length.3. Correct the AWS section numbers in Sec. 5.2.2.1, Items 4 and 5, page 29, as follows:4. Ultrasonic (UT) in accordance with AWS D1.1, Section 6, Part F, accep-tance criteria in accordance with Part C, 6.13.1; or in accordance with ASME Section V, Article
3、4, acceptance criteria in accordance with ASME Section VIII, Div. 1, appendix 12; or API 5L, Annex E.5. Radiographic (RT) in accordance with AWS D1.1, Section 6, Part E, accep-tance criteria in accordance with Part C, 6.12.1; or in accordance with ASME Section V, Article 2, acceptance criteria in accordance with ASME Section VIII, Div. 1, Part UW, UW-51, or UW-52 as applicable; or API 5L, Annex E.