BS EN 1110-2010 Flexible sheets for waterproofing Bitumen sheets for roof waterproofing Determination of flow resistance at elevated temperature《防水柔性薄板 屋面防水用薄沥青板 高温度下耐流动性的测定》.pdf

上传人:confusegate185 文档编号:548629 上传时间:2018-12-09 格式:PDF 页数:14 大小:1.16MB
下载 相关 举报
BS EN 1110-2010 Flexible sheets for waterproofing Bitumen sheets for roof waterproofing Determination of flow resistance at elevated temperature《防水柔性薄板 屋面防水用薄沥青板 高温度下耐流动性的测定》.pdf_第1页
第1页 / 共14页
BS EN 1110-2010 Flexible sheets for waterproofing Bitumen sheets for roof waterproofing Determination of flow resistance at elevated temperature《防水柔性薄板 屋面防水用薄沥青板 高温度下耐流动性的测定》.pdf_第2页
第2页 / 共14页
BS EN 1110-2010 Flexible sheets for waterproofing Bitumen sheets for roof waterproofing Determination of flow resistance at elevated temperature《防水柔性薄板 屋面防水用薄沥青板 高温度下耐流动性的测定》.pdf_第3页
第3页 / 共14页
BS EN 1110-2010 Flexible sheets for waterproofing Bitumen sheets for roof waterproofing Determination of flow resistance at elevated temperature《防水柔性薄板 屋面防水用薄沥青板 高温度下耐流动性的测定》.pdf_第4页
第4页 / 共14页
BS EN 1110-2010 Flexible sheets for waterproofing Bitumen sheets for roof waterproofing Determination of flow resistance at elevated temperature《防水柔性薄板 屋面防水用薄沥青板 高温度下耐流动性的测定》.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 1110:2010Flexible sheets forwaterproofing Bitumensheets for roof waterproofing Determination of flowresistance at elevatedtemperatureLicensed Copy: Wang Bin, ISO/EXCHANGE C

2、HINA STANDARDS, 15/04/2011 03:17, Uncontrolled Copy, (c) BSIBS EN 1110:2010 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1110:2010. Itsupersedes BS EN 1110:2000 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/5

3、46/1, Waterproofing Sheets - Reinforced bitumenmembranes.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2011

4、ISBN 978 0 580 71037 7ICS 91.100.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2011.Amendments issued since publicationDate Text affectedLicensed Co

5、py: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 15/04/2011 03:17, Uncontrolled Copy, (c) BSIBS EN 1110:2010EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1110 December 2010 ICS 91.100.50 Supersedes EN 1110:1999English Version Flexible sheets for waterproofing - Bitumen sheets for roof waterproofin

6、g - Determination of flow resistance at elevated temperature Feuilles souples dtanchit - Feuilles dtanchit de toitures bitumineuses - Dtermination de la rsistance au fluage temprature leve Abdichtungsbahnen - Bitumenbahnen fr Dachabdichtungen - Bestimmung der Wrmestandfestigkeit This European Standa

7、rd was approved by CEN on 28 November 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning

8、such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its

9、own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, It

10、aly, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-10

11、00 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1110:2010: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 15/04/2011 03:17, Uncontrolled Copy, (c) BSIBS EN 1110:2010EN 1110:2010 (E) 2 Contents Page Forewor

12、d 3Introduction .41 Scope 52 Normative references 53 Terms and definitions .54 Principle 55 Apparatus .66 Sampling .67 Preparation of test specimens .68 Procedure .68.1 Preparation for test 68.2 Determination of flow resistance at a specified temperature .78.3 Determination of flow resistance limit

13、.79 Calculation of results, evaluation and precision of test method 79.1 Flow resistance 79.2 Flow resistance limit .79.3 Precision of test method .79.3.1 General 79.3.2 Repeatability .89.3.3 Reproducibility .810 Test report 8Bibliography . 10Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 15

14、/04/2011 03:17, Uncontrolled Copy, (c) BSIBS EN 1110:2010EN 1110:2010 (E) 3 Foreword This document (EN 1110:2010) has been prepared by Technical Committee CEN/TC 254 “Flexible sheets for waterproofing”, the secretariat of which is held by NEN. This European Standard shall be given the status of a na

15、tional standard, either by publication of an identical text or by endorsement, at the latest by June 2011, and conflicting national standards shall be withdrawn at the latest by June 2011. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent r

16、ights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1110:1999. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standa

17、rd: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United K

18、ingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 15/04/2011 03:17, Uncontrolled Copy, (c) BSIBS EN 1110:2010EN 1110:2010 (E) 4 Introduction This European Standard is intended for characterisation and/or classification of bitumen sheets as manufactured or supplied for use. The test meth

19、od relates exclusively to products or to their components where appropriate, and not to waterproofing membrane systems composed of such products and installed in the works. This test method is intended to be used in conjunction with EN 13707. This test is used to determine the flow resistance of the

20、 coating or to determine the flow resistance limit of a bitumen sheet. The test result depends on the type of coating, the sheet thickness, type and position of the reinforcement and type and mass of the granules on the surface. The use of test results to directly compare the performance of the coat

21、ing in sheets of different composition is strictly limited because of the influence of other parameters which have not been quantified. Results from sheets with the same composition can be used to compare the performance of the coating directly. The test primarily serves to characterize bitumen shee

22、ts. It can also be used to evaluate the change in flow resistance limit as a result of artificial ageing. It is not recommended to correlate the test results directly to the actual performance expected at elevated temperatures in service. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 15/04/

23、2011 03:17, Uncontrolled Copy, (c) BSIBS EN 1110:2010EN 1110:2010 (E) 5 1 Scope This European Standard specifies the determination of flow resistance of bitumen sheets at elevated temperature. The test is carried out at a specified temperature or consecutively at different temperatures in order to d

24、etermine the flow resistance limit. Therefore, the test can be used to provide proof of the flow resistance required for a product or to determine the flow resistance limit specific to the product e.g. in order to establish the change in this behaviour as a result of artificial ageing. The test is n

25、ot applicable to bitumen sheets without reinforcement. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (includ

26、ing any amendments) applies. EN 13416, Flexible sheets for waterproofing Bitumen, plastic and rubber sheets for roof waterproofing Rules for sampling 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 flow resistance ability of bitumen sheet tes

27、t specimen to be suspended vertically under specified temperature conditions without the coating moving by more than 2 mm and no occurrence of falling droplets 3.2 flow resistance limit F highest temperature where less than 2 mm displacement of the coating of a vertically suspended bitumen sheet tes

28、t specimen is measured and no falling droplets from the coating of the test specimen are observed 3.3 flow maximum difference between the longitudinal dimension of the test specimen before and after heating within the oven 3.4 falling droplets oily constituents emitted from the coating of the sheet,

29、 which are observed after heating, on a white piece of paper placed under the test specimen during the heating within the oven NOTE Mineral particles (e.g. slate, sand, talcum) are not a part of the coating and should therefore not be assessed as falling droplets. 4 Principle Test specimens taken fr

30、om the test sample are suspended vertically in an oven at a specified temperature. The maximum longitudinal dimensions of the test specimen are measured before and after being heated in the oven. The displacement is calculated as the difference between the longitudinal dimension over the full width

31、of the test specimen, before and after being heated within the oven. Failure is defined as a difference greater than 2,0 mm and/or the occurrence of droplets. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 15/04/2011 03:17, Uncontrolled Copy, (c) BSIBS EN 1110:2010EN 1110:2010 (E) 6 5 Appara

32、tus 5.1 Oven with forced air circulating (without fresh air supply) and a maximum temperature deviation of 2 C in the test area. After the door has been opened for 30 s, the recovery period to attain the working temperature again shall not exceed 5 min. 5.2 Thin metal wire, S-shaped 5.3 Siliconized

33、paper 5.4 Caliper with an accuracy of 0,1 mm 5.5 White coloured paper able to resist the testing temperatures 6 Sampling Test samples shall be taken in accordance with EN 13416. Rectangular test specimens with the following dimensions: length X0(100 1) mm, width 50 mm to 100 mm, as required by the t

34、ests described in 8.2 or 8.3, are taken from the test sample uniformly over the width of the sheet and with the larger dimension in the transversal direction of the sheet. The test specimens shall not be taken within 150 mm of the edges of the sheet. The test specimens shall be numbered consecutivel

35、y, beginning from one edge of the sheet. NOTE For practical reasons the minimum width and maximum width are defined. This accommodates the common practise. Lower dimensions than 50 mm could possibly influence the test result and are impractical. Larger dimensions than 100 mm could result in bending

36、of the test specimen during testing which could possibly influence the result. 7 Preparation of test specimens Any protective film shall be removed, preferably by applying a strip of adhesive tape to it at ambient temperature, cooling the test specimen to e.g. the presumed cold bending temperature a

37、nd then pulling the adhesive tape from the test specimen. Alternatively, or additionally the film can be removed by means of a compressed air jet (maximum pressure approximately 0,5 MPa, nozzle diameter approximately 0,5 mm). The test specimens are then conditioned prior to the test for at least 2 h

38、 at (23 2) C on a flat surface so that they do not touch each other and not to stick to the surface. If necessary, a separating sheet of siliconized paper shall be used to prevent sticking. 8 Procedure 8.1 Preparation for test The oven is preheated to the specified test temperature. For the duration

39、 of the test the temperature shall not vary by more than 2 C inside the test area. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 15/04/2011 03:17, Uncontrolled Copy, (c) BSIBS EN 1110:2010EN 1110:2010 (E) 7 8.2 Determination of flow resistance at a specified temperature The three test speci

40、mens are provided with a thin S-shaped metal wire fixed in the middle of the short side of the test specimen and at a distance of approximately 15 mm from the top edge. The length X0of each test specimen is measured. The prepared test specimens are suspended vertically at the same height in the oven

41、 with at least 30 mm distance between them. A white coloured piece of paper is placed underneath the test specimens. The time for placing the test specimens and paper in the oven shall not exceed 30 s. The heating period is (120 2) min after inserting the test specimens. As soon as the heating perio

42、d is completed, the test specimens shall be removed from the oven without contacting each other and allowed to cool for at least 2 h at (23 2) C in a horizontal position. Measure after the heating and cooling period over the whole width of the three test specimens if the longitudinal dimension (from

43、 top to bottom) is less or equal to (X0+ 2) mm (see Figure 1). Observe on the white coloured paper the occurrence of any droplet coming from the test specimen. 8.3 Determination of flow resistance limit The flow resistance limit shall be determined by means of preliminary tests on individual test sp

44、ecimens at different temperatures at intervals of 5 C. The purpose of these preliminary tests is to find two temperature steps T and (T + 5) C within which the following conditions are reached: the displacement dimension L 2 mm and no droplets at temperature T and the displacement dimension L 2 mm a

45、nd/or occurrence of droplets at temperature (T + 5) C. A new test specimen shall be used for each temperature step. After these two temperatures have been determined in the preliminary test the flow properties are determined in accordance with 8.2 on a series of three test specimen. The tests are ca

46、rried out at the two temperatures T and (T + 5) C. A new series of test specimen shall be used for each temperature. 9 Calculation of results, evaluation and precision of test method 9.1 Flow resistance The flow resistance at a specified temperature is regarded as having passed the test, if the long

47、itudinal dimension of the three test specimens from the top to the bottom over the full width does not exceed (X0+ 2) mm and no falling droplets have been observed. 9.2 Flow resistance limit The flow resistance limit (F) is determined and given to the lowest temperature (T). 9.3 Precision of test me

48、thod 9.3.1 General The precision of the test method was verified by an interlaboratory test on an APP modified polyester reinforced sheet and on a SBS modified polyester reinforced sheet. Based on the results of this inter laboratory test CEN/TC 254/SC 1 concluded that the precision of this test met

49、hod is equal or better than the EN 1110:1999 test method. Therefore, the precision values of the EN 1110:1999, which were determined by Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 15/04/2011 03:17, Uncontrolled Copy, (c) BSIBS EN 1110:2010EN 1110:2010 (E) 8 an initial international interlaboratory test following ISO 5725:1986, are maintained within this standard. These precision values relate to sheets with polyester reinforcement. 9.3.2 Repeatability Repeatability standard

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1