1、BS EN 12566-1:2016Small wastewater treatmentsystems for up to 50 PTPart 1: Prefabricated septic tanksBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 12566-1:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 12566-1:2016.
2、 It supersedes BS EN 12566-1:2000 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee B/505, Wastewater engineering.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to inclu
3、de all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 91476 8 ICS 13.060.30 Compliance with a British Standard cannot confer immunity from legal obligations.This B
4、ritish Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 12566-1:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12566-1 August 2016 ICS 13.060.30 Sup
5、ersedes EN 12566-1:2000English Version Small wastewater treatment systems for up to 50 PT - Part 1: Prefabricated septic tanks Petites installations de traitement des eaux uses jusqu 50 PTE - Partie 1: Fosses septiques prfabriques Kleinklranlagen fr bis zu 50 EW - Teil 1: Werkmig hergestellte Faulgr
6、uben This European Standard was approved by CEN on 25 June 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical r
7、eferences concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a
8、 CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Maced
9、onia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROP
10、ISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12566-1:2016 EBS EN 12566-1:2016EN 12566-1:2016 (E) 2 Contents Page European foreword .
11、 6 1 Scope 8 2 Normative references 8 3 Terms and definitions . 8 4 Product characteristics . 9 4.1 Dimensions 9 4.1.1 Inlets, outlets and connections. 9 4.1.2 Ventilation . 9 4.1.3 Design Basis 9 4.2 Load bearing capacity 9 4.3 Watertightness 10 4.3.1 General . 10 4.3.2 Water test 10 4.3.3 Vacuum t
12、est 10 4.3.4 Pneumatic pressure test 10 4.4 Hydraulic efficiency . 10 4.5 Design . 10 4.6 Access . 10 4.7 Durability 11 4.8 Reaction to fire 11 4.8.1 General . 11 4.8.2 Septic tank classified as Class A1 without the need for testing . 11 4.8.3 Septic tank classified according to the test results 12
13、4.9 Dangerous substances 12 5 Testing, assessment and sampling methods 12 5.1 Load bearing capacity . 12 5.1.1 General . 12 5.1.2 Load bearing capacity determined by calculation . 13 5.1.3 Load bearing capacity determined by testing . 13 5.2 Watertightness 15 5.3 Hydraulic efficiency . 15 6 Assessme
14、nt and verification of constancy of performance AVCP 16 6.1 General . 16 6.2 Type testing 16 6.2.1 General . 16 6.2.2 Test samples, testing and compliance criteria 17 6.2.3 Test reports 17 6.2.4 Shared other party results 17 6.2.5 Cascading determination of the product type results 18 6.3 Factory pr
15、oduction control 19 6.3.1 General . 19 6.3.2 Requirements 20 6.3.3 Product specific requirements 23 6.3.4 Initial inspection of factory and of FPC 23 6.3.5 Continuous surveillance of FPC . 24 BS EN 12566-1:2016EN 12566-1:2016 (E) 3 6.3.6 Procedure for modifications . 24 6.3.7 One-off products, pre-p
16、roduction products (e.g. prototypes) and products produced in very low quantity . 24 7 Classification and designation . 25 7.1 Classification 25 7.2 Nominal capacity. 25 8 Marking, labelling and packaging . 25 8.1 Marking 25 8.2 Installation instructions . 26 8.3 Operating and maintenance instructio
17、ns 26 Annex A (normative) Watertightness and nominal capacity tests 27 A.1 General . 27 A.2 Capacity test 27 A.2.1 Sample 27 A.2.2 Procedure 27 A.2.3 Expression of results . 27 A.3 Watertightness tests 27 A.3.1 Selection of the test 27 A.3.2 Water test 27 A.3.2.1 Sample 27 A.3.2.2 Procedure 28 A.3.2
18、.3 Expression of results . 28 A.3.3 Air permeability vacuum test . 28 A.3.3.1 Sample 28 A.3.3.2 Procedure 28 A.3.3.3 Expression of results . 29 A.3.4 Pneumatic pressure test 29 A.3.4.1 Sample 29 A.3.4.2 Procedure 29 A.3.4.3 Expression of results . 30 Annex B (normative) Hydraulic efficiency test . 3
19、1 B.1 General . 31 B.2 Experimental apparatus. 31 B.3 Synthetic materials used for testing 32 B.4 Preparation of test . 32 B.5 Test parameters 32 B.6 Procedure 33 B.7 Calculation of test results 33 BS EN 12566-1:2016EN 12566-1:2016 (E) 4 Annex C (informative) Information for execution . 34 C.1 Examp
20、les for outlet devices 34 C.2 Openings in internal walls 35 Annex D (normative) Test methods for structural behaviour 36 D.1 Selection of test method 36 D.2 Concrete septic tank 36 D.2.1 Crushing test methods 36 D.2.2 Test procedures 37 D.2.2.1 Type A test (vertical load) . 37 D.2.2.1.1 Sample 37 D.
21、2.2.1.2 Procedure . 37 D.2.2.1.3 Expression of results 37 D.2.2.2 Type B test (horizontal load) . 38 D.2.2.2.1 Sample 38 D.2.2.2.2 Procedure . 38 D.2.2.2.3 Expression of results 38 D.2.2.3 Type C test (vertical load) . 39 D.2.2.3.1 Sample 39 D.2.2.3.2 Procedure . 39 D.2.2.3.3 Expression of results 3
22、9 D.3 Polyethylene septic tank . 39 D.3.1 General . 39 D.3.2 Vertical load test . 39 D.3.2.1 Sample 39 D.3.2.2 Procedure 40 D.3.2.3 Expression of results . 40 D.4 Determination of mechanical characteristics of test samples used for calculation 40 D.4.1 Concrete . 40 D.4.2 Glass Reinforced Plastic .
23、41 D.5 Vacuum test for Glass Reinforced Plastic or steel septic tank . 41 D.6 Pit test. 41 D.6.1 Sample 41 D.6.2 Procedure 41 D.6.3 Expression of results . 42 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation 43 ZA.1 Scope a
24、nd relevant characteristics 43 BS EN 12566-1:2016EN 12566-1:2016 (E) 5 ZA.2 Procedure of attestation of conformity of prefabricated septic tanks 44 ZA.2.1 System(s) of AVCP . 44 ZA.2.2 Declaration of performance (DoP) . 47 ZA.2.2.1 General . 47 ZA.2.2.2 Content . 47 ZA.2.2.3 Example of DoP . 48 ZA.3
25、 CE marking and labelling . 50 Bibliography . 53 BS EN 12566-1:2016EN 12566-1:2016 (E) 6 European foreword This document (EN 12566-1:2016) has been prepared by Technical Committee CEN/TC 165 “Waste water engineering”, the secretariat of which is held by DIN. This European Standard shall be given the
26、 status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2017, and conflicting national standards shall be withdrawn at the latest by May 2018. Attention is drawn to the possibility that some of the elements of this document may be the s
27、ubject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12566-1:2000. The differences between this version and EN 12566-1:2000 are mainly editorial changes according to the Construction Product Regulation (C
28、PR). This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. T
29、he standard series EN 12566 “Small wastewater treatment systems for up to 50 PT” contains the following parts (see Figure 1): Part 1: Prefabricated septic tank (this document); Part 3: Packaged and/or site assembled domestic wastewater treatment plants; Part 4: Septic tanks assembled in situ from pr
30、efabricated kits; Part 6: Prefabricated treatment unit used for septic tank effluent; Part 7: Prefabricated tertiary treatment unit. For filtration systems, CEN/TC 165 decided to publish the following CEN Technical reports, which are considered as Code of practices and do not specify treatment requi
31、rements: Part 2: Soil infiltration systems Part 5: Pre-treated Effluent Filtration systems BS EN 12566-1:2016EN 12566-1:2016 (E) 7 Key A domestic wastewater 1 prefabricated septic tank B septic tank effluent 2 soil infiltration system C treated infiltrated effluent 3 packaged and/or site assembled d
32、omestic wastewater treatment plant D treated wastewater 4 septic tank assembled in situ from prefabricated kit E tertiary treated wastewater 5 pre-treated effluent filtration system 6 prefabricated treatment unit used for septic tank effluent 7 prefabricated tertiary treatment unit National regulati
33、ons may specify different arrangements between the products described in the standard series EN 12566. Figure 1 Scheme related to the arrangement of the parts of EN 12566 According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to i
34、mplement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Roma
35、nia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 12566-1:2016EN 12566-1:2016 (E) 8 1 Scope This part of this standard specifies the requirements for prefabricated septic tanks and ancillary equipment used for the partial treatment of domestic wastewater for a
36、 population 50 PT. Pipes sizes, loads, watertightness, marking and quality control are specified. The following cases are excluded: 1) Septic tanks receiving grey water only; 2) In situ constructed septic tanks. 2 Normative references The following documents, in whole or in part, are normatively ref
37、erenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12566-3:2016, Small wastewater treatment systems up to 50 PT Part 3:
38、Packaged and/or site assembled domestic wastewater treatment plants EN 16323, Glossary of wastewater engineering terms EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests EN 13369, Common rules for precast concr
39、ete products EN ISO 14125, Fibre-reinforced plastic composites Determination of flexural properties (ISO 14125) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 16323:2014 and the following apply. 3.1 extension shaft component which, placed on the top
40、of the septic tank, allows it to be fitted flush with the ground surface or slightly above ground surface, permits installations to be fitted below the frost line, allows accessibility and enables maintenance work to be carried out. Depending on the requirements, it may be vertical extension pieces
41、of the installation housing, or components, which are fitted over maintenance access holes and manholes 3.2 nominal capacity (NC) numerical designation of the volume of a septic tank, expressed as an integer in cubic metres 3.3 prefabricated septic tank single piece factory made unit, including inle
42、t and outlet level openings which leaves the factory completed, controlled and ready for installation BS EN 12566-1:2016EN 12566-1:2016 (E) 9 3.4 product family group of products in which, for the purpose of evaluation, the selected property(s) is/are similar for all products within the group Note 1
43、 to entry: The definition of family takes into account at least similar shape, equipment, materials and conditions of end use and ensures the minimum hydraulic efficiency and minimum structural behaviour for all the products in the range. Note 2 to entry: The minimum level of performance (hydraulic
44、efficiency and structural behaviour) are given by the test carried out on one model of the family. 4 Product characteristics 4.1 Dimensions 4.1.1 Inlets, outlets and connections Minimum size of nominal diameter of inlet and outlet according to the nominal capacity of equipment is: 100 ND 6 m3; 150 N
45、D 6 m3. For design of outlet devices, see some examples in Annex C (informative). 4.1.2 Ventilation Adequate ventilation of the septic tank and the inlet pipework shall be provided to prevent the accumulation of fermentation gases. 4.1.3 Design Basis Depending on the end use, one or more of the foll
46、owing design criteria may need to be stated. a) Population load; b) Minimum sizing criteria including sludge storage capacity; c) Additional design criteria for domestic wastewater flows from sources such as hotels, restaurants or commercial premises. 4.2 Load bearing capacity Test methods and value
47、s for mechanical characteristics of the materials of the tank, used for calculation of the load bearing capacity of the tank, shall be in accordance with EN 12566-3:2016, Annex D. The septic tank shall resist the loads resulting from handling, installation and use including desludging and maintenanc
48、e, for their design life. When tested according to 5.1, the load bearing capacity of the septic tank is declared as: maximum allowed height of backfill (in meters); possibility to install the septic tank in wet or dry site, expressed as WET with the indication of the maximum height of the water tabl
49、e measured from the base of the septic tank or DRY. BS EN 12566-1:2016EN 12566-1:2016 (E) 10 4.3 Watertightness 4.3.1 General The septic tank shall meet at least one of the requirements given in 4.3.2 to 4.3.4 when tested according to the methods described in Annex A. 4.3.2 Water test When tested according to A.3, the water loss for septic tank shall be measured after 30 min. For tanks made of concrete it shall be 0,1 l/m2of the internal wet surface of the external walls. For tanks made from plastics or other material, no leakage shal