1、BSI Standards PublicationSpecifications for particular types of winding wiresPart 39: Glass-fibre braided resin or varnish-impregnated, bare or enamelled rectangular copper wire, temperature index 180BS EN 60317-39:2016National forewordThis British Standard is the UK implementation of EN 60317-39:20
2、16. It is identical to IEC 60317-39:2015. It supersedes BS EN 60317-39:1995 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee L/-/99, Miscellaneous Standards - Electrical.A list of organizations represented on this committee can be obtained onrequest to i
3、ts secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 83425 7ICS 29.060.10Compliance with a British Standard
4、cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2016.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60317-39:2016EUROPEAN STANDARD NORME EUROPENNE
5、EUROPISCHE NORM EN 60317-39 January 2016 ICS 29.060.10 Supersedes EN 60317-39:1994 English Version Specifications for particular types of winding wires - Part 39: Glass-fibre braided resin or varnish-impregnated, bare or enamelled rectangular copper wire, temperature index 180 (IEC 60317-39:2015) Sp
6、cifications pour types particuliers de fils de bobinage - Partie 39: Fil de section rectangulaire en cuivre nu ou maill, recouvert dune tresse de fibres de verre imprgnes de rsine ou de vernis, indice de temprature 180 (IEC 60317-39:2015) Technische Lieferbedingungen fr bestimmte Typen von Wickeldra
7、hten - Teil 39: Flachdrhte aus Kupfer, blank oder lackisoliert, umsponnen mit Glasgewebe, imprgniert mit Harz oder Lack, Temperaturindex 180 (IEC 60317-39:2015) This European Standard was approved by CENELEC on 2015-08-26. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations
8、 which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member.
9、 This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
10、CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Neth
11、erlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management C
12、entre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60317-39:2016 E BS EN 60317-39:2016EN 60317-39:2016 2 European foreword The text of document 55/1460/CDV, future edition 2 of IEC 60317-39
13、, prepared by IEC/TC 55 “Winding wires“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60317-39:2016. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsem
14、ent (dop) 2016-07-15 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2019-01-15 This document supersedes EN 60317-39:1994. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELE
15、C and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60317-39:2015 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following note
16、s have to be added for the standards indicated: IEC 60264 Series NOTE Harmonized as EN 60264 Series. IEC 60317 Series NOTE Harmonized as EN 60317 Series. IEC 60851 Series NOTE Harmonized as EN 60851 Series. BS EN 60317-39:2016EN 60317-39:2016 3 Annex ZA (normative) Normative references to internatio
17、nal publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the
18、 referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is availabl
19、e here: www.cenelec.eu Publication Year Title EN/HD Year IEC 60317-0-5 2006 Specifications for particular types of winding wires - Part 0-5: General requirements - Glass-fibre braided resin or varnish impregnated, bare or enamelled rectangular copper wire EN 60317-0-5 2007 BS EN 60317-39:2016 2 IEC
20、60317-39:2015 IEC 2015 CONTENTS FOREWORD . 3 INTRODUCTION . 5 1 Scope 6 2 Normative references 6 3 Terms, definitions, general notes and appearance . 6 3.1 Terms and definitions 6 3.2 General notes . 6 3.2.1 Methods of test 6 3.2.2 Winding wire 6 3.3 Appearance 7 4 Dimensions 7 5 Electrical resistan
21、ce 7 6 Elongation . 7 7 Springiness . 7 8 Flexibility and adherence . 7 9 Heat shock 7 10 Cut-through . 7 11 Resistance to abrasion 7 12 Resistance to solvents . 7 13 Breakdown voltage 7 14 Continuity of insulation 8 15 Temperature index 8 16 Resistance to refrigerants 8 17 Solderability 8 18 Heat o
22、r solvent bonding . 8 19 Dielectric dissipation factor 8 20 Resistance to transformer oil . 8 21 Loss of mass . 8 23 Pin hole test 8 30 Packaging . 8 Bibliography 9 BS EN 60317-39:2016IEC 60317-39:2015 IEC 2015 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ SPECIFICATIONS FOR PARTICULAR TYPES OF WIND
23、ING WIRES Part 39: Glass-fibre braided resin or varnish-impregnated, bare or enamelled rectangular copper wire, temperature index 180 FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (I
24、EC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports
25、, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-
26、governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of
27、IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are ac
28、cepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote internat
29、ional uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the
30、latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users s
31、hould ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other d
32、amage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use
33、of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent ri
34、ghts. International Standard IEC 60317-39 has been prepared by IEC technical committee 55: Winding wires. This second edition cancels and replaces the first edition published in 1992, Amendment 1:1997 and Amendment 2:2005. This edition constitutes a technical revision. This edition includes the foll
35、owing significant technical changes with respect to the previous edition: revision to Clause 2, Normative references; new 3.2.2 containing general notes on winding wire, formerly a part of the scope; revision to references to IEC 60317-0-5 to clarify that their application is normative. BS EN 60317-
36、39:2016 4 IEC 60317-39:2015 IEC 2015 The text of this standard is based on the following documents: CDV Report on voting 55/1460/CDV 55/1499/RVC Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has be
37、en drafted in accordance with the ISO/IEC Directives, Part 2. A list of all parts in the IEC 60317 series, published under the general title Specifications for particular types of winding wires, can be found on the IEC website. The numbering of clauses in this standard is not continuous from Clauses
38、 20 and 30 in order to reserve space for possible future wire requirements prior to those for wire packaging. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC website under “http:/webstore.iec.ch“ in the data related
39、to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. BS EN 60317-39:2016IEC 60317-39:2015 IEC 2015 5 INTRODUCTION This part of IEC 60317 forms an element of a series which deals with insulated wires used for windings in
40、 electrical equipment. The series has three groups describing: 1) Winding wires Test methods (IEC 60851 series); 2) Specifications for particular types of winding wires (IEC 60317 series); 3) Packaging of winding wires (IEC 60264 series). BS EN 60317-39:2016 6 IEC 60317-39:2015 IEC 2015 SPECIFICATIO
41、NS FOR PARTICULAR TYPES OF WINDING WIRES Part 39: Glass-fibre braided resin or varnish-impregnated, bare or enamelled rectangular copper wire, temperature index 180 1 Scope This part of IEC 60317 specifies the requirements of glass-fibre braided impregnated, bare, or grade 1 or grade 2 enamelled rec
42、tangular copper winding wire, temperature index 180. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. 2
43、Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendme
44、nts) applies. IEC 60317-0-5:2006, Specifications for particular types of winding wires Part 0-5: General requirements Glass-fibre braided, resin or varnish impregnated, bare or enamelled rectangular copper wire 3 Terms, definitions, general notes and appearance 3.1 Terms and definitions For the purp
45、oses of this document, the terms and definitions given in 3.1 of IEC 60317-0-5:2006 apply. 3.2 General notes 3.2.1 Methods of test Subclause 3.2 of IEC 60317-0-5:2006 applies. In case of inconsistencies between IEC 60317-0-5:2006 and this part of IEC 60317, the latter shall prevail. 3.2.2 Winding wi
46、re The enamelled wire shall have a temperature index of at least 180 and shall be agreed between purchaser and supplier. The temperature index of the wire is dependent upon the type of impregnating agent used. The impregnating agent applied to the polyester glass fibre shall have a minimum temperatu
47、re index of 180. Coverings applicable to this specification have the following grades of thickness: BGL1, bare conductor with one braided layer of glass fibre; BGL2, bare conductor with two braided layers of glass fibre; BS EN 60317-39:2016IEC 60317-39:2015 IEC 2015 7 grade 1 BGL1, enamelled grade 1
48、 (grade 1) with one braided layer of glass fibre (BGL1); grade 1 BGL2, enamelled grade 1 (grade 1) with two braided layers of glass fibre (BGL2); grade 2 BGL1, enamelled grade 2 (grade 2) with one braided layer of glass fibre (BGL1); grade 2 BGL2, enamelled grade 2 (grade 2) with two braided layers
49、of glass fibre (BGL2). 3.3 Appearance Subclause 3.3 of IEC 60317-0-5:2006 applies. 4 Dimensions Clause 4 of IEC 60317-0-5:2006 applies. 5 Electrical resistance Clause 5 of IEC 60317-0-5:2006 applies. 6 Elongation Clause 6 of IEC 60317-0-5:2006 applies. 7 Springiness Clause 7 of IEC 60317-0-5:2006 applies. 8 Flexibility and adherence Clause 8 of IEC 60317-0-5:2006 applies. 9 Heat shock Test inappropriate. 10 Cut-through Test inappropriate. 11 Resistance to abrasion Test inapp