BS EN 60598-2-24-2013 Luminaires Particular requirements Luminaires with limited surface temperatures《灯具 特殊要求 限制表面温度的灯具》.pdf

上传人:visitstep340 文档编号:575933 上传时间:2018-12-13 格式:PDF 页数:14 大小:1.14MB
下载 相关 举报
BS EN 60598-2-24-2013 Luminaires Particular requirements Luminaires with limited surface temperatures《灯具 特殊要求 限制表面温度的灯具》.pdf_第1页
第1页 / 共14页
BS EN 60598-2-24-2013 Luminaires Particular requirements Luminaires with limited surface temperatures《灯具 特殊要求 限制表面温度的灯具》.pdf_第2页
第2页 / 共14页
BS EN 60598-2-24-2013 Luminaires Particular requirements Luminaires with limited surface temperatures《灯具 特殊要求 限制表面温度的灯具》.pdf_第3页
第3页 / 共14页
BS EN 60598-2-24-2013 Luminaires Particular requirements Luminaires with limited surface temperatures《灯具 特殊要求 限制表面温度的灯具》.pdf_第4页
第4页 / 共14页
BS EN 60598-2-24-2013 Luminaires Particular requirements Luminaires with limited surface temperatures《灯具 特殊要求 限制表面温度的灯具》.pdf_第5页
第5页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BSI Standards PublicationLuminairesPart 2-24: Particular requirements Luminaires with limited surface temperaturesBS EN 60598-2-24:2013National forewordThis British Standard is the UK implementation of EN 60598-2-24:2013. It isidentical to IEC 60598-2-24:2013. It supersedes BS EN 60598-2-24:1999,whi

2、ch will be withdrawn on 24 July 2016.The UK participation in its preparation was entrusted by TechnicalCommittee CPL/34, Lamps and Related Equipment, to SubcommitteeCPL/34/4, Luminaires.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication

3、does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013ISBN 978 0 580 72867 9ICS 29.140.40 Compliance with a British Standard cannot confer immunity fromle

4、gal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 August 2013.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60598-2-24:2013EUROPEAN STANDARD EN 60598-2-24 NORME EUROPENNE EUROPISCHE NORM

5、 August 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means

6、reserved worldwide for CENELEC members. Ref. No. EN 60598-2-24:2013 E ICS 29.140.40 Supersedes EN 60598-2-24:1998 English version Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures (IEC 60598-2-24:2013) Luminaires - Partie 2-24: Exigences particulires - Lu

7、minaires avec surfaces tempratures limites (CEI 60598-2-24:2013) Leuchten Teil 2-24: Besondere Anforderungen Leuchten mit begrenzter Oberflchentemperatur (IEC 60598-2-24:2013) This European Standard was approved by CENELEC on 2013-07-24. CENELEC members are bound to comply with the CEN/CENELEC Inter

8、nal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any

9、CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the offi

10、cial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg,

11、Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 60598-2-24:2013EN 60598-2-24:2013 - 2 - Foreword The text of document 34D/1094/FDIS, future edition 2 of IEC 60598-2-24, prepared by SC 34D “Luminaires“ of

12、IEC/TC 34 “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60598-2-24:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endors

13、ement (dop) 2014-04-24 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2016-07-24 This document supersedes EN 60598-2-24:1998. EN 60598-2-24:2013 includes the following significant technical changes with respect to EN 60598-2-24:1998: a) change of

14、 required degree of protection from IP6X to IP4X to harmonize with the international wiring rules; b) temperature limits introduced for glass surface of any light source exposed to risk of dust. This standard is to be read in conjunction with EN 60598-1, Luminaires Part 1: General requirements and t

15、ests. NOTE In this standard, the following print types are used: requirements: in roman type. test specifications: in italic type. notes: in small roman type. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shal

16、l not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). Endorsement notice The text of the International Standard IEC 6059

17、8-2-24:2013 was approved by CENELEC as a European Standard without any modification. BS EN 60598-2-24:2013- 3 - EN 60598-2-24:2013 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are

18、normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified

19、by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60364-4-42 - Low voltage electrical installations - Part 4-42: Protection for safety - Protection against thermal effects HD 60364-4-42 - IEC 60598-1 - Luminaires - Part 1: General requirem

20、ents and tests EN 60598-1 - ISO 4225 1994 Air quality - General aspects - Vocabulary - - BS EN 60598-2-24:2013 2 60598-2-24 IEC:2013 CONTENTS 24.1 Scope 5 24.2 Normative references 5 24.3 General test requirements 5 24.4 Terms and definitions 5 24.5 Classification of luminaires 6 24.6 Marking . 6 24

21、.7 Construction 6 24.8 Creepage distances and clearances . 7 24.9 Provision for earthing . 7 24.10 Terminals and electrical connections 7 24.11 External and internal wiring 7 24.12 Protection against electric shock 7 24.13 Endurance test and thermal test. 7 24.13.1 Temperature limits normal operatio

22、n . 7 24.13.2 Temperature limits abnormal operation . 8 24.13.3 Temperature limits fault conditions . 8 24.14 Resistance to dust, solid objects and moisture . 8 24.15 Insulation resistance and electric strength 8 24.16 Resistance to heat, fire and tracking 8 Figure 1 Symbol for luminaires with limit

23、ed surface temperatures . 6 BS EN 60598-2-24:201360598-2-24 IEC:2013 5 LUMINAIRES Part 2-24: Particular requirements Luminaires with limited surface temperatures 24.1 Scope This part of the IEC 60598 series specifies requirements for luminaires intended for use where the necessity of limited tempera

24、ture on the outer surface exists, due to the risk of thermal effects, combustion or degradation of materials but where the risk of explosion in the atmosphere does not exist. The luminaires are for use with electric light sources on supply voltages not exceeding 1 000 V. This standard specifically e

25、xcludes requirements for luminaires for use in explosive gas atmospheres and explosive dust atmospheres. 24.2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the editi

26、on cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60364-4-42, Low-voltage electrical installations Part 4-42: Protection for safety Protection against thermal effects IEC 60598-1, Luminaires Part 1: General requirements an

27、d tests ISO 4225:1994, Air quality General aspects Vocabulary 24.3 General test requirements The provisions of Section 0 in IEC 60598-1 apply. The tests described in each appropriate section of IEC 60598-1 shall be carried out in the order listed in this standard. 24.4 Terms and definitions For the

28、purposes of this document, the terms and definitions given in Section 1 of IEC 60598-1 apply, as well as the following apply. 24.4.1 dust small solid particles in the atmosphere which settle out under their own weight, but which may remain suspended in air for some time (includes dust and grit as de

29、fined in ISO 4225) 24.4.2 explosive gas atmosphere mixture with air, under atmospheric conditions, of flammable substances in the form of gas or vapour which, after ignition, permits self sustaining flame propagation SOURCE: IEC 60050-426:2008, 426-01-07 BS EN 60598-2-24:2013 6 60598-2-24 IEC:2013 2

30、4.4.3 explosive dust atmosphere a mixture with air, under atmospheric conditions, of flammable substances in the form of dust, fibres or flyings which, after ignition, permits self-sustaining propagation SOURCE: IEC 60050-426:2008, 426-01-08 24.5 Classification of luminaires Luminaires shall be clas

31、sified in accordance with the provisions of Section 2 of IEC 60598-1. Additionally luminaires complying with this section are classified suitable for use in locations specified in IEC 60364-4-42 as follows. a) For use in environments where no unusual accumulation of dust is expected. b) For use in e

32、nvironments where an accumulation of non-conductive dust on the luminaire may be expected. c) For use in environments where an accumulation of conductive dust on the luminaire may be expected. 24.6 Marking The provisions of Section 3 of IEC 60598-1 apply together with the following requirements. 24.

33、6.1 Luminaires shall be marked with the symbol (see Figure 1). This marking shall be visible and meet the requirements of 3.2 c) of IEC 60598-1. Figure 1 Symbol for luminaires with limited surface temperatures 24.6.2 From the manufacturers literature it shall be evident to which location the luminai

34、re is intended in accordance with the luminaires classification as given in 24.5 of this standard. 24.7 Construction The provisions of Section 4 of IEC 60598-1 apply, together with the requirements of 24.7.1 and 24.7.2 below. 24.7.1 Luminaires shall be provided with an enclosure providing a degree o

35、f protection of at least IP4X or in the presence of dust, IP5X or in the presence of conductive dust, IP6X. For certain locations the international wiring rules may require at least IP5X or IP6X (see IEC 60364-4-42). Compliance is checked by inspection. D D BS EN 60598-2-24:201360598-2-24 IEC:2013 7

36、 24.7.2 Surfaces where dust may accumulate and all surfaces greater than 7,5 mm wide and non-vertical surfaces shall comply with the requirements of horizontal surfaces. Vertical surfaces not complying with spacing requirements in 24.13 shall comply with the limits for horizontal surfaces. Complianc

37、e is checked by inspection. 24.8 Creepage distances and clearances The provisions of Section 11 of IEC 60598-1 apply. 24.9 Provision for earthing The provisions of Section 7 of IEC 60598-1 apply. 24.10 Terminals and electrical connections The provisions of Sections 14 and 15 of IEC 60598-1 apply. 24

38、.11 External and internal wiring The provisions of Section 5 of IEC 60598-1 apply. 24.12 Protection against electric shock The provisions of Section 8 of IEC 60598-1 apply. 24.13 Endurance test and thermal test The provisions of Section 12 of IEC 60598-1 apply, together with the requirements of 24.1

39、3.1 to 24.13.3 below. Luminaires with the symbol shall be subjected to the relevant tests given in 12.4, 12.5, 12.6 and 12.7 of Section 12 of IEC 60598-1 after the test(s) given in 9.2 but before the test(s) given in 9.3 of Section 9 of IEC 60598-1 specified in 24.14 of this standard. Where the gap

40、between vertical surfaces is less than 30 mm, the temperature limit for horizontal surfaces shall apply. 24.13.1 Temperature limits Normal operation For luminaires with the symbol, a temperature of 90 C on all horizontal surfaces of the luminaire exposed to the accumulation of dust shall not be exce

41、eded, at 1,06 times the rated voltage and, on all vertical external surfaces, the maximum temperature shall not exceed 150 C at 1,06 times the rated voltage. If a luminaire has an outer surface likely to be positioned against part of a building (wall or similar), with a temperature higher than 90 C,

42、 but not exceeding 150 C, the luminaire shall be provided with mounting instructions cautioning against such positioning. D D BS EN 60598-2-24:2013 8 60598-2-24 IEC:2013 The temperature of any part of the glass surface of any light source shall not exceed 150 C. Only applicable for light sources exp

43、osed to risk of dust. NOTE Light sources in luminaires which are rated IP5X or less are expected to be exposed to risk of dust accumulation. 24.13.2 Temperature limits Abnormal operation For luminaires with the symbol, the requirements of 12.5.1 of Section 12 of IEC 60598-1 and 24.13.1 above apply.

44、24.13.3 Temperature limits Fault conditions For luminaires with the symbol, the requirements of 12.6 of Section 12 of IEC 60598-1 apply with the addition that temperatures on horizontal surfaces of the luminaire exposed to the accumulation of dust shall not exceed 115 C. In addition the temperature

45、of 24.13.1 above applies for all vertical external surfaces and the glass surfaces of the light source. 24.14 Resistance to dust, solid objects and moisture The provisions of Section 9 of IEC 60598-1 apply. For luminaires with the symbol, the order of tests specified in Section 9 of IEC 60598-1 shal

46、l be as specified in 24.13. 24.15 Insulation resistance and electric strength The provisions of Section 10 of IEC 60598-1 apply. 24.16 Resistance to heat, fire and tracking The provisions of Section 13 of IEC 60598-1 apply. D D D BS EN 60598-2-24:201360598-2-24 IEC:2013 9 Bibliography IEC 60050 (all

47、 parts), International Electrotechnical Vocabulary (available at ). _ BS EN 60598-2-24:2013This page deliberately left blankThis page deliberately left blankBSI is the national body responsible for preparing British Standards and other standards-related publications, information and services.BSI is

48、incorporated by Royal Charter. British Standards and other standardization products are published by BSI Standards Limited.British Standards Institution (BSI)BSI Group Headquarters389 Chiswick High Road London W4 4AL UKAbout usWe bring together business, industry, government, consumers, innovators a

49、nd others to shape their combined experience and expertise into standards -based solutions.The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process. Organizations of all sizes and across all sectors choose standards to help them achieve their goals.Information on standardsWe can provide you with the knowledge that your organization needs to succeed. Find out more about British Sta