1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Radio frequency and coaxialcable assemblies Part 2-3: Detail specification for flexible coaxialcable assemblies F
2、requency range 0 MHz to 1 000 MHz, IEC 61169-8 connectorsBS EN 60966-2-3:2009National forewordThis British Standard is the UK implementation of EN 60966-2-3:2009. It isidentical to IEC 60966-2-3:2009. It supersedes BS EN 60966-2-3:2003 whichis withdrawn.The UK participation in its preparation was en
3、trusted to Technical CommitteeEPL/46, Cables, wires and waveguides, radio frequency connectors and acces-sories for communication and signalling.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the neces
4、sary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 61639 6ICS 33.120.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Comm
5、ittee on 30 September 2009Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60966-2-3:2009EUROPEAN STANDARD EN 60966-2-3 NORME EUROPENNE EUROPISCHE NORM August 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electr
6、otechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60966-2-3:2009 E ICS 33.120.10 Supersedes EN 60966-2-3:2003E
7、nglish version Radio frequency and coaxial cable assemblies - Part 2-3: Detail specification for flexible coaxial cable assemblies - Frequency range 0 MHz to 1 000 MHz, IEC 61169-8 connectors (IEC 60966-2-3:2009) Ensembles de cordons coaxiaux et de cordons pour frquences radiolectriques - Partie 2-3
8、: Spcification particulire pour cordons coaxiaux souples - Bande de frquences de 0 MHz 1 000 MHz, connecteurs CEI 61169-8 (CEI 60966-2-3:2009) Konfektionierte Koaxial- und Hochfrequenzkabel - Teil 2-3: Bauartspezifikation fr flexible konfektionierte Koaxialkabel - Frequenzbereich 0 MHz bis 1000 MHz,
9、 Steckverbinder nach IEC 61169-8 (IEC 60966-2-3:2009) This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without
10、 any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language
11、made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark
12、, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 60966-2-3:2009EN 60966-2-3:2009 - 2 - Foreword The tex
13、t of document 46/302/FDIS, future edition 3 of IEC 60966-2-3, prepared by IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60966-2-3 on 2009-07-01. This Europ
14、ean Standard supersedes EN 60966-2-3:2003. The major change with respect to EN 60966-2-3:2003 is the reference to EN 61169-8 instead of EN 60169-8. This detail specification is to be read in conjunction with EN 60966-1:1999, with EN 60966-2-1:2009, and with EN 60966-2-2:2003. The following dates wer
15、e fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-07-01 Annex ZA has been added by CENELE
16、C. _ Endorsement notice The text of the International Standard IEC 60966-2-3:2009 was approved by CENELEC as a European Standard without any modification. _ BS EN 60966-2-3:2009- 3 - EN 60966-2-3:2009 Annex ZA (normative) Reference documents with their corresponding European publications The followi
17、ng referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by
18、common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60966-1 1999 Radio frequency and coaxial cable assemblies - Part 1: Generic specification - General requirements and test methods EN 60966-1 1999 IEC 60966-2-1 2008 Radio frequency and coaxial
19、 cable assemblies - Part 2-1: Sectional specification for flexible coaxial cable assemblies EN 60966-2-1 2009 IEC 60966-2-2 2003 Radio frequency and coaxial cable assemblies - Part 2-2: Blank detail specification for flexible coaxial cable assemblies EN 60966-2-2 2003 IEC 61169-8 -1)Radio-frequency
20、connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristics impedance 50 ohms (type BNC) EN 61169-8 20072)IEC 61196-6 -1)Coaxial communication cables - Part 6: Sectional specification for CATV drop
21、cables - - 1)Undated reference. 2)Valid edition at date of issue. BS EN 60966-2-3:2009 4 60966-2-3 IEC:2009(E) INTRODUCTION This part of IEC 60966 is a detail specification that applies to flexible coaxial cables described in IEC 60096-2. It relates to flexible coaxial cable assemblies using BNC con
22、nectors. This detail specification gives subfamily requirements and severities which shall be applied . Under qualification approval, the qualification will be conducted in accordance with 12.2 of IEC 60966-2-1 taking into account the specified variants. Only the tests whose results might depend on
23、the variants will be repeated. Under capability approval, the qualification will be conducted on the relating CQCs as defined in 12.3 of IEC 60966-2-1 and described in the CM. Unless otherwise specified in the CM, only lot-by-lot tests from groups Ba and Eb will be conducted on delivered products, a
24、ll other tests will be performed on CQCs as defined in 12.3 of IEC 60966-2-1 and described in the CM. Reference documents IEC 60966-1:1999, Radio frequency and coaxial cable assemblies Part 1: Generic specification General requirements and test methods IEC 60966-2-1:2008, Radio frequency and coaxial
25、 cable assemblies Part 2-1: Sectional specification for flexible coaxial cable assemblies IEC 60966-2-2:2003, Radio frequency and coaxial cable assemblies Part 2-2: Blank detail specification for flexible coaxial cable assemblies IEC 61169-8, Radio-frequency connectors Part 8: Sectional specificatio
26、n RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock Characteristic impedance 50 ohm (type BNC) IEC 61196-6, Coaxial communication cables Part 6: Sectional specification for CATV drop cables BS EN 60966-2-3:200960966-2-3 IEC:2009(E) 5 RADIO FREQUENCY AND
27、 COAXIAL CABLE ASSEMBLIES Part 2-3: Detail specification for flexible coaxial cable assemblies Frequency range 0 MHz to 1 000 MHz, IEC 61169-8 connectors 1 Prepared by IEC TC 46 2 Document No. 60966-2-3 Issue: Third Issue Date: 06/01/09 3 Available from: IEC 3 rue de Varemb Genve Suisse 4 Generic sp
28、ecification: IEC 60966-1 Sectional Specification: IEC 60966-2-1 Blank detail specification: IEC 60966-2-2 5 Additional references: Detail specification for flexible coaxial cable assemblies NOTE Example diagram, manufacturer to insert actual diagram LA or B type IEC 2298/08 6 Maximum diameter 105M T
29、est voltage 500 V 1 min Inner conductor continuity 8.12 OK Low voltage d.c. Outer conductor continuity 8.12 10 m After tensile test 9.1 Mechanical Tensile 9.1 30 N Interface OK Duration 1 min Test 8.12 Flexure 9.2 500 cycles Force 5 N 20/min Test 8.12 Flexing endurance 9.3 500 cycles 20 cycles min T
30、est 8.12 Cable assembly crushing 9.4 600 N min Test 8.2 a The relevant standard could be the generic, the sectional or both of them.Recommended grouping of test Recommended severity 20 Group 21 SubclauseaTest 22 Periodicity23 NC IL 24 NQAAQL25 n 26 c 27 Length of specimen Ba 7.2 7.3 Visual inspectio
31、n Dimensional inspection lot by lot lot by lot S3 S3 4.0 4.0 Ez 8.2 Uniformity of impedance lot by lot II 1.0 Eb 8.10 8.11 8.12 Voltage proof Insulation resistance Inner and outer conductor continuity lot by lot lot by lot lot by lot II II III 1.0 1.0 1.0 Mn 9.1 9.2 9.3 9.4 Tensile Flexure Flexing e
32、ndurance Cable assembly crushing 3 years 3 years 3 years 3 years 3 0 On a CQC variant 1 l =300 mm a The relevant standard could be the generic, the sectional or both of them._ BS EN 60966-2-3:2009This page deliberately left blankBSI is the independent national body responsible for preparing British
33、Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.British Standards Institution (BSI)raising standards worldwideBSI Group Headquarters389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standard
34、s are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments oreditions.It is the constant aim of BSI to improve the quality of our products andservices. We would be grateful if anyone finding an inaccuracy orambiguity while using this Br
35、itish Standard would inform the Secretary ofthe technical committee responsible, the identity of which can be foundon the inside front cover.Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 8996 7400BSI offers members an individual updating service called PLUS whichensures that subscribers automatically rece
36、ive the latest editions ofstandards.Buying standardsOrders for all BSI, international and foreign standards publicationsshould be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: You may also buy directly using a debit/credit card from the BSI Shopon the web
37、site response to orders for international standards, it is BSI policy tosupply the BSI implementation of those that have been publishedas British Standards, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, European andinternational standards t
38、hrough its Library.Various BSI electronic information services are also available which givedetails on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: Subscribing members of BSI are kept up to date with standardsdevelopments and
39、 receive substantial discounts on the purchase priceof standards. For details of these and other benefits contact MembershipAdministration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards via BritishStandards Online can be found at
40、information about BSI is available on the BSI website CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of thepublications of the international standardization bodies. Except as permitted under theCopyright, Designs and Patents Act 1988 no extract may be r
41、eproduced, stored in a retrievalsystem or transmitted in any form or by any means electronic, photocopying, recording orotherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard of necessarydetails such as symbols, and size,
42、type or grade designations. If these details are to be used forany other purpose than implementation then the prior written permission of BSI must beobtained. Details and advice can be obtained from the Copyright & Licensing Manager.Tel: +44 (0)20 8996 7070 Email: WB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 2