1、BSI Standards PublicationIndustrial communication networks Fieldbus specificationsPart 4-19: Data-link layer protocol specification Type 19 elementsBS EN 61158-4-19:2014National forewordThis British Standard is the UK implementation of EN 61158-4-19:2014. It isidentical to IEC 61158-4-19:2014. It su
2、persedes BS EN 61158-4-19:2012which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee AMT/7, Industrial communications: process measurement and control, including fieldbus.A list of organizations represented on this committee can be obtained onrequest to its se
3、cretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 79447 6ICS 25.040.40; 35.100.20; 35.110Compliance with a Bri
4、tish Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 November 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 61158-4-19:2014EUROPEAN STANDARDN
5、ORME EUROPENNEEUROPISCHE NORMEN 61158-4-19 October 2014 ICS 25.040.40; 35.100.20; 35.110 Supersedes EN 61158-4-19:2012 English Version Industrial communication networks - Fieldbus specifications - Part 4-19: Data-link layer protocol specification - Type 19elements (IEC 61158-4-19:2014) Rseaux de com
6、munication industriels - Spcifications des bus de terrain - Partie 4-19: Spcification du protocole de la couche liaison de donnes - Elments de type 19 (CEI 61158-4-19:2014) Industrielle Kommunikationsnetze - Feldbusse - Teil 4-19:Protokollspezifikation des Data Link Layer(Sicherungsschicht) - Typ 19
7、-Elemente (IEC 61158-4-19:2014) This European Standard was approved by CENELEC on 2014-09-19. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to
8、-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tran
9、slation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, D
10、enmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Europea
11、n Committee for Electrotechnical Standardization Comit Europen de Normalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide fo
12、r CENELEC Members. Ref. No. EN 61158-4-19:2014 E EN 61158-4-19 :2014 - 2 - Foreword The text of document 65C/762/FDIS, future edition 3 of IEC 61158-4-19, prepared by SC 65C “Industrial networks” of IEC/TC 65 “Industrial-process measurement, control and automation“ was submitted to the IEC-CENELEC p
13、arallel vote and approved by CENELEC as EN 61158-4-19:2014. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-06-19 latest date by which the national standards conflic
14、ting with the document have to be withdrawn (dow) 2017-09-19 This document supersedes EN 61158-4-19:2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all
15、such patent rights. This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association. Endorsement notice The text of the International Standard IEC 61158-4-19:2014 was approved by CENELEC as a European Standard without any modificati
16、on. In the official version, for bibliography, the following notes have to be added for the standards indicated: IEC 61131 Series NOTE Harmonised as EN 61131 Series IEC 61158-1:2014 NOTE Harmonised as EN 61158-1:2014 IEC 61158-3-19:2014 NOTE Harmonised as EN 61158-3-19:2014 IEC 61158-5-16:2007 NOTE
17、Harmonised as EN 61158-5-16:2007 IEC 61158-5-19:2014 NOTE Harmonised as EN 61158-5-19:2014 IEC 61158-6-16:2007 NOTE Harmonised as EN 61158-6-16:2007 IEC 61158-6-19:2014 NOTE Harmonised as EN 61158-6-19:2014 IEC 61784-1 NOTE Harmonised as EN 61784-1 IEC 61784-2 NOTE Harmonised as EN 61784-2 IEC 61800
18、-7 Series NOTE Harmonised as EN 61800-7 Series IEC 61800-7-201 NOTE Harmonised as EN 61800-7-201 IEC 61800-7-202 NOTE Harmonised as EN 61800-7-202 IEC 61800-7-203 NOTE Harmonised as EN 61800-7-203 IEC 61800-7-204 NOTE Harmonised as EN 61800-7-204 BS EN 61158-4-19:2014- 3 - EN 61158-4-19 :2014 Annex
19、ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies.
20、For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the Eu
21、ropean Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 61158-4-16 2007 Industrial communication networks - Fieldbus specifications Part 4-16: Data-link layer protocol specification - Type 16 elements EN 61158-4-16 2008 ISO/IEC 7498-1 - Informat
22、ion technology - Open Systems Interconnection - Basic reference model: The basic model - - ISO/IEC 7498-3 - Information technology - Open Systems Interconnection - Basic reference model: Naming and addressing - - ISO 8601 - Data elements and interchange formats - Information interchange - Representa
23、tion of dates and times - - ISO/IEC 8802-3 - Information technology - Telecommunications and information exchange between systems - Local and metropolitan area networks - Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer s
24、pecifications - - IEEE 802.3 - IEEE Standard for Information technology - Telecommunications and information exchange between systems - Local and metropolitan area networks - Specific requirements Part 3: Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Lay
25、er Specifications - - IETF RFC 879 - The TCP Maximum Segment Size and Related Topics - - BS EN 61158-4-19:2014 2 IEC 61158-4-19:2014 IEC 2014 CONTENTS INTRODUCTION . 23 1 Scope . 25 General . 25 1.1Specifications 25 1.2Procedures 25 1.3Applicability . 25 1.4Conformance . 26 1.52 Normative references
26、 . 26 3 Terms, definitions, symbols, acronyms, abbreviations and conventions 26 Reference model terms and definitions 26 3.1Additional Type 19 terms and definitions . 26 3.2Symbols 30 3.3Acronyms and abbreviations 31 3.4Additional conventions 32 3.54 DL-protocol overview 33 Overview . 33 4.1General
27、DLPDU identification 34 4.2General DLPDU structure 35 4.3DLPDU header 35 4.4MDT DLPDU . 36 4.5AT DLPDU 48 4.6Mechanisms of connections . 59 4.75 DL management . 69 Overview . 69 5.1Initialization of cyclic communication . 69 5.2Network topologies 91 5.3Redundancy of RT communication with ring topolo
28、gy 102 5.4Hot-plug procedure 105 5.5Status procedures . 110 5.66 Data transmission methods 111 Overview . 111 6.1Service channel (SVC) 111 6.2RT Channel . 125 6.3Transmission and activation of Type 19 time . 125 6.4Multiplexing of real-time data with data containers 127 6.5Handling of Real-time bits
29、 . 138 6.6SMP 141 6.7Oversampling 146 6.87 Telegram timing and DLPDU handling 151 Communication mechanisms . 151 7.1Synchronization . 206 7.2Processing methods of connection data 215 7.38 Communication Error handling and monitoring 218 Invalid telegrams . 218 8.1BS EN 61158-4-19:2014IEC 61158-4-19:2
30、014 IEC 2014 3 Response to MDT and AT telegram failure 218 8.2Error counters in the slave 219 8.3Status codes of Type 19 communication profile (SCP). 219 8.4Priority of diagnosis classes 222 8.5Annex A (normative) IDN Identification numbers . 223 A.1 IDN specification . 223 A.1.1 Introduction . 223
31、A.1.2 Element 1: structure of IDN . 223 A.1.3 Element 2: structure of name . 224 A.1.4 Element 3: structure of attribute . 225 A.1.5 Element 4: structure of unit 227 A.1.6 Element 5: structure of minimum value 227 A.1.7 Element 6: structure of maximum value . 228 A.1.8 Element 7: structure of operat
32、ion data . 228 A.1.9 Structure of Data status . 230 A.2 Identification numbers in numerical orders 231 A.3 Detailed specification of communication-related IDNs . 235 A.3.1 IDN S-0-0014 Interface status . 235 A.3.2 IDN S-0-0021 IDN-list of invalid operation data for CP2 236 A.3.3 IDN S-0-0026 IDN all
33、ocation of producer RTB word container . 237 A.3.4 IDN S-0-0027 IDN allocation of consumer RTB word container . 238 A.3.5 IDN S-0-0127 CP3 transition check . 239 A.3.6 IDN S-0-0128 CP4 transition check . 239 A.3.7 IDN S-0-0144 Producer RTB word container . 240 A.3.8 IDN S-0-0145 Consumer RTB word co
34、ntainer . 240 A.3.9 IDN S-0-0187 IDN-list of configurable data as producer 241 A.3.10 IDN S-0-0188 IDN-list of configurable data as consumer . 242 A.3.11 IDN S-0-0328 Bit allocation of producer RTB word container . 242 A.3.12 IDN S-0-0329 Bit allocation of consumer RTB word container . 243 A.3.13 ID
35、N S-0-0360 MDT data container A1 . 243 A.3.14 IDN S-0-0361 MDT data container B1 . 244 A.3.15 IDN S-0-0362 MDT data container A list index 245 A.3.16 IDN S-0-0363 MDT data container B list index 246 A.3.17 IDN S-0-0364 AT data container A1 247 A.3.18 IDN S-0-0365 AT data container B1 248 A.3.19 IDN
36、S-0-0366 AT data container A list index . 249 A.3.20 IDN S-0-0367 AT data container B list index . 250 A.3.21 IDN S-0-0368 Data container A pointer . 251 A.3.22 IDN S-0-0369 Data container B pointer . 252 A.3.23 IDN S-0-0370 MDT data container A/B configuration list . 254 A.3.24 IDN S-0-0371 AT data
37、 container A/B configuration list 254 A.3.25 IDN S-0-0394 List IDN 255 A.3.26 IDN S-0-0395 List index 255 A.3.27 IDN S-0-0396 Number of list elements 256 A.3.28 IDN S-0-0397 List segment . 257 A.3.29 IDN S-0-0398 IDN list of configurable real-time bits as producer . 258 A.3.30 IDN S-0-0399 IDN list
38、of configurable real-time bits as consumer 258 A.3.31 IDN S-0-0444 IDN-list of configurable data in the AT data container . 259 BS EN 61158-4-19:2014 4 IEC 61158-4-19:2014 IEC 2014 A.3.32 IDN S-0-0445 IDN-list of configurable data in the MDT data container . 259 A.3.33 IDN S-0-0450 MDT data containe
39、r A2 . 260 A.3.34 IDN S-0-0451 MDT data container A3 . 260 A.3.35 IDN S-0-0452 MDT data container A4 . 261 A.3.36 IDN S-0-0453 MDT data container A5 . 262 A.3.37 IDN S-0-0454 MDT data container A6 . 263 A.3.38 IDN S-0-0455 MDT data container A7 . 264 A.3.39 IDN S-0-0456 MDT data container A8 . 265 A
40、.3.40 IDN S-0-0457 MDT data container A9 . 266 A.3.41 IDN S-0-0458 MDT data container A10 . 267 A.3.42 IDN S-0-0459 MDT data container B2 . 268 A.3.43 IDN S-0-0480 AT data container A2 269 A.3.44 IDN S-0-0481 AT data container A3 270 A.3.45 IDN S-0-0482 AT data container A4 271 A.3.46 IDN S-0-0483 A
41、T data container A5 272 A.3.47 IDN S-0-0484 AT data container A6 273 A.3.48 IDN S-0-0485 AT data container A7 274 A.3.49 IDN S-0-0486 AT data container A8 275 A.3.50 IDN S-0-0487 AT data container A9 276 A.3.51 IDN S-0-0488 AT data container A10 277 A.3.52 IDN S-0-0489 AT data container B 278 A.3.53
42、 IDN S-0-0490 MDT data container A2 configuration list . 279 A.3.54 IDN S-0-0491 MDT data container A3 configuration list . 280 A.3.55 IDN S-0-0492 MDT data container A4 configuration list . 281 A.3.56 IDN S-0-0493 MDT data container A5 configuration list . 281 A.3.57 IDN S-0-0494 MDT data container
43、 A6 configuration list . 282 A.3.58 IDN S-0-0495 MDT data container A7 configuration list . 283 A.3.59 IDN S-0-0496 MDT data container A8 configuration list . 283 A.3.60 IDN S-0-0497 MDT data container A9 configuration list . 284 A.3.61 IDN S-0-0498 MDT data container A10 configuration list . 284 A.
44、3.62 IDN S-0-0500 AT data container A2 configuration list 285 A.3.63 IDN S-0-0501 AT data container A3 configuration list 286 A.3.64 IDN S-0-0502 AT data container A4 configuration list 286 A.3.65 IDN S-0-0503 AT data container A5 configuration list 287 A.3.66 IDN S-0-0504 AT data container A6 confi
45、guration list 288 A.3.67 IDN S-0-0505 AT data container A7 configuration list 288 A.3.68 IDN S-0-0506 AT data container A8 configuration list 289 A.3.69 IDN S-0-0507 AT data container A9 configuration list 289 A.3.70 IDN S-0-0508 AT data container A10 configuration list 290 A.3.71 IDN S-0-1000.0.1 A
46、ctive SCP Classes 291 A.3.72 IDN S-0-1000 SCP Type b) for use in the testing and procurement of equipment; c) as part of an agreement for the admittance of systems into the open systems environment; d) as a refinement to the understanding of time-critical communications within OSI. This standard is
47、concerned, in particular, with the communication and interworking of sensors, effectors and other automation devices. By using this standard together with other standards positioned within the OSI or fieldbus reference models, otherwise incompatible systems may work together in any combination. NOTE
48、 Attention is drawn to the fact that use of the associated protocol type(s) is restricted by its (their) intellectual-property-right holder(s). In all cases, the commitment to limited release of intellectual-property-rights made by the holder(s) of those rights permits a particular data-link layer p
49、rotocol type to be used with physical layer and application layer protocols in Type combinations as specified explicitly in the profile parts. Use of the various protocol type(s) in other combinations may require permission from their respective intellectual-property-right holders. The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed that compliance with this document may involve the use of patents concerning Type 19 elements and possibly other types given in this document as follo