BS EN 61169-29-2005 Radio-frequency connectors - Sectional specification - Miniature radio frequency coaxial connectors model screw snap-on push-pull or quick-lock slide-in (rack ac.pdf

上传人:figureissue185 文档编号:577010 上传时间:2018-12-13 格式:PDF 页数:32 大小:975.87KB
下载 相关 举报
BS EN 61169-29-2005 Radio-frequency connectors - Sectional specification - Miniature radio frequency coaxial connectors model screw snap-on push-pull or quick-lock slide-in (rack ac.pdf_第1页
第1页 / 共32页
BS EN 61169-29-2005 Radio-frequency connectors - Sectional specification - Miniature radio frequency coaxial connectors model screw snap-on push-pull or quick-lock slide-in (rack ac.pdf_第2页
第2页 / 共32页
BS EN 61169-29-2005 Radio-frequency connectors - Sectional specification - Miniature radio frequency coaxial connectors model screw snap-on push-pull or quick-lock slide-in (rack ac.pdf_第3页
第3页 / 共32页
BS EN 61169-29-2005 Radio-frequency connectors - Sectional specification - Miniature radio frequency coaxial connectors model screw snap-on push-pull or quick-lock slide-in (rack ac.pdf_第4页
第4页 / 共32页
BS EN 61169-29-2005 Radio-frequency connectors - Sectional specification - Miniature radio frequency coaxial connectors model screw snap-on push-pull or quick-lock slide-in (rack ac.pdf_第5页
第5页 / 共32页
亲,该文档总共32页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BRITISH STANDARD BS EN 61169-29:2005 Radio-frequency connectors Part 29: Sectional specification Miniature radio frequency coaxial connectors model screw, snap-on, push-pull or quick-lock, slide-in (rack and panel applications) Characteristic impedance 50 ohms (type 1,0/2,3) 50 ohms and 75 ohms appl

2、ications The European Standard EN 61169-29:2005 has the status of a British Standard ICS 33.120.30BS EN 61169-29:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 9 November 2005 BSI 9 November 2005 ISBN 0 580 46743 0 National foreword Thi

3、s British Standard is the official English language version of EN 61169-29:2005. It is identical with IEC 61169-29:2005. The UK participation in its preparation was entrusted by Technical Committee waveguides, which has the responsibility to: A list of organizations represented on this subcommittee

4、can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search

5、” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obli

6、gations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of p

7、ages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 28, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date Comments EPL/

8、46, Cables, wires and waveguides, RF connectors and accessories for communication and signalling, to Subcommittee EPL/46/2, RF connectors and EUROPEAN STANDARD EN 61169-29 NORME EUROPENNE EUROPISCHE NORM September 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de

9、Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61169-29:2005 E ICS 33.120.30 English

10、version Radio-frequency connectors Part 29: Sectional specification Miniature radio frequency coaxial connectors model screw, snap-on, push-pull or quick-lock, slide-in (rack and panel applications) Characteristic impedance 50 ohms (type 1,0/2,3) 50 ohms and 75 ohms applications (IEC 61169-29:2005)

11、Connecteurs pour frquences radiolectriques Partie 29: Spcification intermdiaire Connecteurs coaxiaux miniatures pour frquences radiolectriques avec accouplements de type vis, pousser-tirer et encliquetage, ou glis (applications de “panneau“ et “fond de panier“) Impdance caractristique 50 ohms (type

12、1,0/2,3) Applications 50 ohms et 75 ohms (CEI 61169-29:2005) Hochfrequenz-Steckverbinder Teil 29: Rahmenspezifikation Koaxiale Miniatur-Hochfrequenzsteckverbinder mit Schraub-, Einrast-, Push-pull- oder Schnellverschluss-, Einschubkupplung (Einschubausfhrung) Wellenwiderstand 50-Ohm (Typ 1,0/2,3) 50

13、-Ohm- und 75-Ohm-Anwendungen (IEC 61169-29:2005) This European Standard was approved by CENELEC on 2005-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any

14、alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made

15、by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland,

16、 France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 61169-29:2005 2 Foreword The text of document 46F/27/FDIS, future edition 1 of IEC 61169-29,

17、prepared by SC 46F, R.F. and microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was submitted to IEC-CENELEC parallel vote and was approved by CENELEC as EN 61169-29 on 2005-07-01. The following dates were fi

18、xed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-07-01 Annex ZA has been added by CENELEC. _

19、 Endorsement notice The text of the International Standard IEC 61169-29:2005 was approved by CENELEC as a European Standard without any modification. _ 3 EN 61169-29:2005 CONTENTS 1 Scope 4 2 Normative references .4 3 IEC type designation 5 4 Interface information.6 5 Quality assessment procedures 1

20、4 6 Instructions for preparation of detail specifications 21 Annex ZA (normative) Normative references to international publications with their corresponding European Publications .28 Figure 1 Interfaces (for dimensions, see Table 1) .6 Figure 2 Locking devices (for dimensions, see Table 2) 8 Figure

21、 3 Gauge pin for centre contact of socket connector10 Figure 4 Outer contact sizing and retention force gauges A and B.11 Figure 5 Plug.12 Figure 6 Socket .13 Table 1 Dimensions of the interfaces7 Table 2 Dimensions of the locking devices .9 EN 61169-29:2005 4 RADIO-FREQUENCY CONNECTORS Part 29: Sec

22、tional specification Miniature radio frequency coaxial connectors model screw, snap-on, push-pull or quick-lock, slide-in (rack and panel applications) Characterisctic impedance 50 (type 1,0/2,3) 50 and 75 applications 1 Scope This part of IEC 61169, which is a sectional specification (SS), provides

23、 information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with screw, snap- on, push-pull or quick-lock, slide-in coupling (rack and panel applications) with a characterisctic impedance of 50 (type 1,0/2,3) for 50 and 75 applications. The connectors are norma

24、lly used with flexible and semi-rigid r.f. cables for low power applications in conjunction with 50 cables in an operating frequency range up to 10 GHz or in conjunction with 75 cables up to 2 GHz. It describes the interface dimensions for general purpose grade 2 connectors, dimensional details for

25、standard test connectors, grade 0, together with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all DS relating to type 1,0/2,3 connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers tes

26、t schedules and inspection requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendm

27、ents) applies. IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods 5 EN 61169-29:2005 3 IEC type designation Type designations are given for each of the various coupling mechanisms: Screw the coupling mechanism consists of a coupling

28、nut (on the plug ) and a thread (on the socket). The tightening torque is achieved by hand. The engagement and separation force depends on the mechanical dimensions of the inner and outer contacts of the plug and socket. Snap on the coupling mechanism consists of a spring device (on the plug) that f

29、its in a suitable shape of the body (on the socket). The engagement and separation force depends on the mechanical dimensions of the inner and outer contact, of the spring device and of the socket body. The coupling mechanism does not prevent accidental disengagements. Push pull or Quick lock (herea

30、fter called push pull) the coupling mechanism consists of a spring device (on the plug) that fits in a suitable shape of the body (on the socket). The engagement and separation force depends on the mechanical dimensions of the inner and outer contact, of the spring element and of the socket body. Th

31、is coupling mechanism prevents accidental disengagements. Slide in the coupling mechanism consists of a nut (on the plug) which allows a float mounting on the panel preventing a radial misalignment. The engagement and separation force depends on the mechanical dimensions of the inner and outer conta

32、cts of the plug and socket. In case of rack and panel applications, the separation range of panels may differ from the fully mated position by 1,7 mm. Connectors conforming to this part of IEC 61169 shall be designated by: a) the reference to this part of IEC 61169: IEC 61169-29; b) the grade number

33、: Grade 0 = standard test connector = G0 Grade 2 = general purpose connector = G2 c) identification number (see Clause 8 of IEC 61169-1). EN 61169-29:2005 6 4 Interface information 4.1 Dimensions 4.1.1 General purpose connectors - Grade 2 Millimetre dimensions are original dimensions. All undimensio

34、ned pictorial configurations are for reference purposes only. Plug Pin contact Flared to meet the gauging requirement Reference plane electrical and mechanical Radius 0,8 0,1 (0,030 0,002) Socket Radius 0,3 max. (0,010 max.) Slotted and closed to meet the gauging requirement Socket resilient contact

35、 S F B A C D E 30 2 K G H R L I M N T O P IEC 820/05 Figure 1 Interfaces (for dimensions, see Table 1) 7 EN 61169-29:2005 Table 1 Dimensions of the interfaces mm in Ref. Min. Max. Min. Max. Note A 0,475 0,520 0,018 7 0,020 5 Diameter B 4,5 0,177 C 5,5 0,217 D 1,15 0,045 E (*) 1 nominal 0,039 nominal

36、 Diameter F 5,4 5,7 0,213 0,224 G 3,00 3,06 0,118 0,120 Diameter H 4,03 4,14 0,159 0,163 Diameter I 1,8 1,9 0,071 0,075 K M 5,5 0,5 L 0,5 0,6 0,020 0,024 M 5,8 5,9 0,228 0,232 N 6,4 6,5 0,252 0,256 O (*) 1 nominal 0,039 nominal Diameter P 1,15 1,75 0,045 0,069 R 3,525 3,600 0,138 8 0,141 7 Diameter

37、S 2,3 nominal 0,091 nominal Diameter T 4,5 0,177 (*) = only for 50 version. EN 61169-29:2005 8 Figure 2 Locking devices (for dimensions, see Table 2) G F F S U T C E A D B M H L* I K R 45 2 P O Figure 2a Screw Reference plane Biased in the forward direction Reference plane 45 2 Biased in the forward

38、 direction Figure 2b Snap-on Figure 2b(bis) Push-pull Figure 2c Slide-in (rack and panel applications) * Separation of panels when fully mated IEC 821/05 9 EN 61169-29:2005 Table 2 Dimensions of the locking devices mm in Ref. Min. Max. Min. Max. Note A 6,44 6,50 0,254 0,256 Diameter B 8,55 8,9 0,337

39、 0,350 C 13,3 13,5 0,524 0,531 D 2,7 3,9 0,106 0,154 E M 5,5 0,5 Thread F 1,95 2,05 0,077 0,081 G 6,4 0,252 H 8,25 8,40 0,325 0,331 I 7,5 7,6 0,295 0,299 K 3,10 3,15 0,122 0,124 L 11,9 13,6 0,469 0,535 M 4,8 4,9 0,189 0,193 O 7,3 0,287 Diameter P 4,2 4,26 0,165 0,168 Diameter R 1,4 1,6 0,055 0,063 S

40、 6,1 0,240 T 7,9 0,311 Diameter U 7,6 0,299 EN 61169-29:2005 10 4.2 Gauges 4.2.1 Gauges for general purpose connectors Millimetre dimensions are original dimensions. All undimensioned pictorial configurations are for reference purposes only. 4.2.1.1 Gauge for socket centre contact 25 5 a 2,0 min. (0

41、,079 min.) IEC 822/05 NOTE Dimensions are in millimetres. Figures in brackets represent inches. Gauge A Maximum material for sizing purposes Gauge B Minimum material for measurement of gauge retention force Mass (weight) of gauge (20 1) g mm in mm in Ref. Min. Max. Min. Max. Min. Max. Min. Max. a 0,

42、516 0,520 0,020 3 0,020 5 0,471 0,475 0,081 5 0,018 7 Material: steel, polished Surface roughness Ra: 0,4 m (16 in) max. Figure 3 Gauge pin for centre contact of socket connector Test procedure: Gauge A shall be inserted once only into the socket centre contact. This is a sizing operation. After thi

43、s, gauge B shall be inserted into the socket centre contact. The contact shall support the mass of the gauge in a vertical downward attitude. NOTE Gauge A is used for qualification approval tests only (see 9.3.4 of IEC 61169-1). The maximum diameter of gauge A corresponds to the maximum diameter of

44、a pin contact. 11 EN 61169-29:2005 4.2.1.2 Gauge for outer contact of plug connector Radius 0,2 0,05 (0,008 0,002) Radius 0,3 0,05 (0,012 0,002) 30 2 a A C B* D IEC 823/05 NOTE Dimensions are in millimetres. Figures in brackets represent inches. * Surface roughness to apply on this length of inside

45、surface ( 1). mm in Ref. Min. Max. Min. Max. Note A 4,1 0,161 Diameter B 7 nominal 0,276 C 9 0,354 D 0,5 0,6 0,020 0,024 Gauge A Maxumum material for sizing purposes Gauge B Minimum material for measurement of gauge retention force Mass (weight) of gauge (70 1) g mm in mm in Ref. Min. Max. Min. Max.

46、 Min. Max. Min. Max. a 3,000 3,006 0,118 1 0,118 3 3,060 3,068 0,120 5 0,120 8 Material: steel, polished Surface roughness Ra: 0,4 m (16 in) max. Figure 4 Outer contact sizing and retention force gauges A and B Test procedure: The resilient plug outer conductor shall be inserted once only into gauge

47、 A. This is a sizing operation. After this, the resilient plug outer conductor shall be inserted into gauge B. The conductor shall support the mass of the gauge in a vertical downward attitude. EN 61169-29:2005 12 4.2.2 Dimensions Standard test connectors Grade 0 Millimetre dimensions are original d

48、imensions. All undimensioned pictorial configurations are for reference purposes only. Pin contact A BC F E D G H I 45 2 Reference plane mechanical and electrical IEC 824/05 mm in Ref. Min. Max. Min. Max. Note A 2,99 3,00 0,117 7 0,118 1 Diameter B 2,30 2,31 0,090 6 0,090 9 Diameter C 5,40 5,70 0,213 0,224 D 0,50 0,52 0,020 1 0,020 5 Diameter E 0,30 0,40 0,012 0,016 F 4,50 0,177 G 5,30 5,50 0,209 0,217 H 0,95 1,15 0,037 0,045 I 0,99 1,00 0,039 0,039 4 Diameter Figure 5 Plug 13 EN 61169-29:2005 Radius 0,8 0,05 (0,031 0,002) 30 2 Radius 0,3 max. (0,010 max.) Socket resilient

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1