1、BSI Standards PublicationTelecontrol equipment and systemsPart 5-601: Transmission protocols Conformance test cases for the IEC 60870-5-101 companion standardPD IEC/TS 60870-5-601:2015National forewordThis Published Document is the UK implementation of IEC/TS 60870-5-601:2015. It supersedes DD IEC/T
2、S 60870-5-601:2006 which iswithdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee PEL/57, Power systems management and associated information exchange.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does
3、 not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 89793 1ICS 33.200Compliance with a British Standard cannot confer immunity fromlegal obli
4、gations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 31 October 2015.Amendments/corrigenda issued since publicationDate Text affectedPUBLISHED DOCUMENTPD IEC/TS 60870-5-601:2015IEC TS 60870-5-601 Edition 2.0 2015-10 TECHNICAL SPECIFICATIO
5、N Telecontrol equipment and systems Part 5-601: Transmission protocols Conformance test cases for the IEC 60870-5-101 companion standard INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 33.200 ISBN 978-2-8322-2926-2 Registered trademark of the International Electrotechnical Commission Warning! Make sur
6、e that you obtained this publication from an authorized distributor. colourinsidePD IEC/TS 60870-5-601:2015 2 IEC TS 60870-5-601:2015 IEC 2015 CONTENTS FOREWORD . 4 1 Scope 6 2 Normative references 6 3 Terms and definitions 7 4 Abbreviated terms . 7 5 Conformance testing for IEC 60870-5-101 . 7 5.1
7、Overview and legend 7 5.2 Configuration parameters for IEC 60870-5-101 . 9 5.3 Verification of IEC 60870-5-101 communication 11 5.4 Conformance Test Procedures 44 5.5 Test results chart 86 5.6 Test results of command transmission 94 Figure 1 Test procedure . 8 Table 1 Configuration Parameters for IE
8、C 60870-5-101 . 9 Table 2 Verification of the physical level 11 Table 3 Verification of the Link Level . 11 Table 4 Verification of the Data Unit Identifier 15 Table 5 Verification of the object address 15 Table 6 Verification of ASDUs for process information in monitor (Normal) direction 16 Table 7
9、 Verification of ASDUs for process information in control (Normal) direction . 35 Table 8 Verification of ASDUs for system information in monitor (Normal) direction . 37 Table 9 Verification of ASDUs for system information in control (Normal) direction 37 Table 10 Verification of ASDUs for parameter
10、s in control (Normal) direction 39 Table 11 Verification of ASDUs for file transfer (in monitor (Normal) and control direction) 41 Table 12 Link Layer Conformance Test Procedures . 44 Table 13 Data Unit Identifier Conformance Test Procedures 45 Table 14 Information object address Conformance Test Pr
11、ocedures 46 Table 15 Station initialization function (unbalanced systems) Conformance Test Procedures . 47 Table 16 Data acquisition by polling function (unbalanced systems) Conformance Test Procedures . 51 Table 17 Station initialization function (balanced systems) Conformance Test Procedures . 52
12、Table 18 Redundant link conformance test procedures 55 Table 19 Cyclic data transmission function Conformance Test Procedures 56 Table 20 Data acquisition through Read function Conformance Test Procedures . 57 Table 21 Acquisition of events function Conformance Test Procedures 58 Table 22 General in
13、terrogation function Conformance Test Procedures . 60 Table 23 Clock synchronization function conformance test procedures 65 Table 24 Command transmission function Conformance Test Procedures 67 PD IEC/TS 60870-5-601:2015IEC TS 60870-5-601:2015 IEC 2015 3 Table 25 Transmission of integrated totals (
14、telecounting) function Conformance Test Procedures . 74 Table 26 Parameter loading function Conformance Test Procedures 78 Table 27 Test procedure function Conformance Test Procedures . 79 Table 28 File transfer procedure function Conformance Test Procedures . 80 Table 29 Delay acquisition procedure
15、 function conformance test procedures . 82 Table 30 Additional Conformance Test Procedures 83 Table 31 Negative Conformance Test Procedures 84 Table 32 PIXIT related Conformance Test Procedures . 85 Table 33 Test results chart 86 Table 34 Test results of single command transmission . 95 Table 35 Tes
16、t results of double command transmission . 96 Table 36 Test results of regulating step command transmission . 98 Table 37 Test results of setpoint command transmission . 100 PD IEC/TS 60870-5-601:2015 4 IEC TS 60870-5-601:2015 IEC 2015 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ TELECONTROL EQUIPMEN
17、T AND SYSTEMS Part 5-601: Transmission protocols Conformance test cases for the IEC 60870-5-101 companion standard FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committ
18、ees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Availabl
19、e Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organi
20、zations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical ma
21、tters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC Natio
22、nal Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, I
23、EC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itse
24、lf does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that t
25、hey have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature
26、 whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced p
27、ublications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. The main task
28、 of IEC technical committees is to prepare International Standards. In exceptional circumstances, a technical committee may propose the publication of a technical specification when the required support cannot be obtained for the publication of an International Standard, despite repeated efforts, or
29、 The subject is still under technical development or where, for any other reason, there is the future but no immediate possibility of an agreement on an International Standard. Technical specifications are subject to review within three years of publication to decide whether they can be transformed
30、into International Standards. This technical specification is to be used in conjunction with IEC 60870-5-101:2003/AMD1:2015. IEC 60870-5-101:2003/AMD1:2015 resolves ambiguities PD IEC/TS 60870-5-601:2015IEC TS 60870-5-601:2015 IEC 2015 5 and inconsistencies discovered by users of the standard and wa
31、s worked out in parallel with IEC 60870-5-601:2006. IEC 60870-5-601, which is a technical specification, has been prepared by IEC technical committee 57: Power systems management and associated information exchange. This second edition cancels and replaces the first edition published in 2006. This e
32、dition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Resolving ambiguities and inconsistencies between IEC 60870-5-101:2003 and IEC TS 60870-5-601:2006; b) Enhancements and optimisation of test cases which
33、 are needed to prove conformance with IEC 60870-5-101:2003; c) Additional negative test cases made to avoid circulation of messages not conformant with IEC 60870-5-101:2003. The text of this technical specification is based on the following documents: Enquiry draft Report on voting 57/1528/DTS 57/15
34、90/RVC Full information on the voting for the approval of this technical specification can be found in the report on voting indicated in the above Table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. A list of all parts of the IEC 60870 series, under the genera
35、l title Telecontrol equipment and systems, can be found on the IEC website. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publicat
36、ion. At this date, the publication will be transformed into an International standard, reconfirmed, withdrawn, replaced by a revised edition, or amended. A bilingual version of this publication may be issued at a later date. IMPORTANT The colour inside logo on the cover page of this publication indi
37、cates that it contains colours which are considered to be useful for the correct understanding of its contents. Users should therefore print this document using a colour printer. PD IEC/TS 60870-5-601:2015 6 IEC TS 60870-5-601:2015 IEC 2015 TELECONTROL EQUIPMENT AND SYSTEMS Part 5-601: Transmission
38、protocols Conformance test cases for the IEC 60870-5-101 companion standard 1 Scope This part of IEC 60870describes test cases for conformance testing of telecontrol equipment, Substation Automation Systems (SAS) and telecontrol systems, including front-end functions of SCADA. The use of this part o
39、f IEC 60870 facilitates interoperability by providing a standard method of testing protocol implementations, but it does not guarantee interoperability of devices. It is expected that using this part of IEC 60870 during testing will minimize the risk of non-interoperability. The goal of this part of
40、 IEC 60870 is to enable unambiguous and standardised evaluation of IEC 60870-5 companion standard protocol implementations. The guidelines and conditions for the testing environment are described in IEC 60870-5-6. The detailed test cases per companion standard, containing among others mandatory and
41、optional mandatory test cases per Basic Application Function, ASDU and transmission procedures, will become available as a technical specification (TS). Other functionality may need additional test cases but this is beyond the scope of this part of IEC 60870. For proper testing, it is recommended to
42、 define these additional test cases. This part of IEC 60870 deals mainly with communication conformance testing; therefore other requirements, such as safety or EMC are not covered. These requirements are covered by other standards (if applicable) and the proof of compliance for these topics is done
43、 in accordance with these standards. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the ref
44、erenced document (including any amendments) applies1.IEC 60870-5-1:1990, Telecontrol equipment and systems Part 5: Transmission protocols Section One: Transmission frame formats IEC 60870-5-2:1992, Telecontrol equipment and systems Part 5: Transmission protocols Section 2: Link transmission procedur
45、es 1The base standard always takes precedence. In case of ambiguity between this part of IEC 60870 and the base standards (IEC 60870-5-1 to IEC 60870-5-5, IEC 60870-5-101), this part of IEC 60870 needs to be clarified or amended. When testing negative behaviour is not described in the base standard,
46、 the behaviour described in this part of IEC 60870 shall prevail and shall be observed. The conformance statement produced after testing shall indicate any lack of conformance to either the test plan or the base standard. PD IEC/TS 60870-5-601:2015IEC TS 60870-5-601:2015 IEC 2015 7 IEC 60870-5-3:199
47、2, Telecontrol equipment and systems Part 5: Transmission protocols Section 3: General structure of application data IEC 60870-5-4:1993, Telecontrol equipment and systems Part 5: Transmission protocols Section 4: Definition and coding of application information elements IEC 60870-5-5:1999, Telecontr
48、ol equipment and systems Part 5: Transmission protocols Section 5: Basic application functions IEC 60870-5-6, Telecontrol equipment and systems Part 5-6: Guidelines for conformance testing for the IEC 60870-5 companion standards IEC 60870-5-101:2003, Telecontrol equipment and systems Part 5-101: Tra
49、nsmission protocols Companion standard for basic telecontrol tasks IEC 60870-5-101:2003/AMD1:2015 IEEE 754, Standard for Binary Floating-Point Arithmetic 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60870-5-6 apply. 4 Abbreviated terms For the purposes of this document, the abbreviations given in IEC 60870-5-6 apply. 5 Conformance testing for