CAN CSA-ISO IEC 14763-1A-2005 Amendment 1 Information technology – Implementation and operation of customer premises cabling – Part 1 Administration.pdf

上传人:figureissue185 文档编号:590549 上传时间:2018-12-15 格式:PDF 页数:5 大小:168.93KB
下载 相关 举报
CAN CSA-ISO IEC 14763-1A-2005 Amendment 1 Information technology – Implementation and operation of customer premises cabling – Part 1 Administration.pdf_第1页
第1页 / 共5页
CAN CSA-ISO IEC 14763-1A-2005 Amendment 1 Information technology – Implementation and operation of customer premises cabling – Part 1 Administration.pdf_第2页
第2页 / 共5页
CAN CSA-ISO IEC 14763-1A-2005 Amendment 1 Information technology – Implementation and operation of customer premises cabling – Part 1 Administration.pdf_第3页
第3页 / 共5页
CAN CSA-ISO IEC 14763-1A-2005 Amendment 1 Information technology – Implementation and operation of customer premises cabling – Part 1 Administration.pdf_第4页
第4页 / 共5页
CAN CSA-ISO IEC 14763-1A-2005 Amendment 1 Information technology – Implementation and operation of customer premises cabling – Part 1 Administration.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 Amendment 1 Information technology Implementation and operation of customer premises cabling Part 1: Administration PRICE CODE IEC 2004 Droits de reproduction rservs Copyright - all rights reserved International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, Switzerla

2、ndTelephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch B For price, see current catalogueCommission Electrotechnique InternationaleInternational Electrotechnical CommissionAmendment 1:2005 toNational Standard of CanadaCAN/CSA-ISO/IEC 14763-1:02Amendment 1:2004 t

3、o International Standard ISO/IEC 14763-1:1999 has been adopted withoutmodification (IDT) as Amendment 1:2005 to CAN/CSA-ISO/IEC 14763-1:02. This Amendment was reviewedby the CSA Technical Committee on Information Technology (TCIT) under the jurisdiction of the StrategicSteering Committee on Informat

4、ion Technology and deemed acceptable for use in Canada.October 2005 2 14763-1 Amend.1 ISO/IEC:2004(E) FOREWORD Amendment 1 to International Standard ISO/IEC 14763-1 was prepared by ISO/IEC subcommittee 25: Interconnection of information technology equipment, of ISO/IEC joint technical committee 1: I

5、nformation technology. This amendment adds a new normative Annex A to ISO/IEC 14763-1 and renumbers the present Annexes accordingly. 14763-1 Amend.1 ISO/IEC:2004(E) 3 Page 12 Insert the new Annex A as follows and renumber the existing annexes A to D accordingly: Annex A (normative) Classes of admini

6、stration A.1 General Four typical classes of administration are specified in this Annex to accommodate various degrees of complexity related to the telecommunications infrastructure. A.2 Determination of class A.2.1 General The most relevant factors in determining the minimum class of administration

7、 are the size and complexity of the infrastructure. The number of telecommunications spaces, such as equipment rooms, common equipment rooms, telecommunications rooms, common telecommunications rooms and entrance facility spaces, is an indicator of the degree of complexity. Classes are scalable and

8、allow expansion without requiring changes to existing identifiers or labels. For mission critical systems, buildings over 7 000 m2or multi-tenant buildings, administration of pathways and spaces, and outside plant elements is strongly recommended. A.2.2 Class 1 Class 1 addresses the administration n

9、eeds of premises that are served by a single equipment room. The latter is the only telecommunication space administered whereas there are no telecommunications rooms and no backbone cabling or outside plant cabling systems to administer. Simple cable pathways will generally be intuitively understoo

10、d and need not be administered. In order to administer cable pathways or fire-stopping locations, class 2 or higher administration systems should be used. Class 1 will typically be managed using a paper-based system or with general purpose spreadsheet software. A.2.3 Class 2 Class 2 administration p

11、rovides for the telecommunications infrastructure administration needs of a single building or of a tenant that is served by a single or multiple telecommunications spaces (e.g., an equipment room with one or more telecommunications rooms) within a single building. Class 2 administration includes al

12、l elements of class 1 administration, plus identifiers for backbone cabling, multiple-element grounding and bonding systems, and fire-stopping. Cable pathways may be intuitively understood, administration of these elements is therefore optional. Class 2 may be managed using a paper-based system, gen

13、eral purpose spreadsheet software, or special-purpose cable management software. A.2.4 Class 3 Class 3 administration addresses the needs of a campus, including its buildings and outside plant elements. Class 3 administration includes all elements of class 2 administration, plus identifiers for buil

14、dings and campus cabling. Administration of building pathways and spaces, and outside plant elements is recommended. Class 3 may be managed with a paper-based 4 14763-1 Amend.1 ISO/IEC:2004(E) system, general purpose spreadsheet software or special-purpose cable management software. A.2.5 Class 4 Cl

15、ass 4 administration addresses the needs of a multi-site system. Class 4 administration includes all elements of class 3 administration, plus an identifier for each site, and optional identifiers for inter-campus elements, such as wide area network connections. For mission-critical systems, large bu

16、ildings or multi-tenant buildings, administration of pathways and spaces and outside plant elements is strongly recommended. Class 4 may be managed with general purpose spreadsheet software or special-purpose cable management software. A.3 Service records of link Requirements for minimum and optiona

17、l records in general are described in 4.5. Link records shall contain as a minimum the details provided in the following example: - The link passed Class D measurement at installation (4thAugust 2002). - It was re-terminated and re-tested at cross-connect (1stDecember 2002) because of a defective conductor. _ ICS 35.200

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1