下载 相关 举报
COE CEGS 14580-2000 PNEUMATIC-TUBE SYSTEM NOTICE 1-6 (2000) INCORPORATED SPECIAL CHANGE (2000) INCORPORATED《气送管系统 加入了1-6(2000)注意事项以及(2000)的特别变更事项》.pdf_第1页
第1页 / 共14页
COE CEGS 14580-2000 PNEUMATIC-TUBE SYSTEM NOTICE 1-6 (2000) INCORPORATED SPECIAL CHANGE (2000) INCORPORATED《气送管系统 加入了1-6(2000)注意事项以及(2000)的特别变更事项》.pdf_第2页
第2页 / 共14页
COE CEGS 14580-2000 PNEUMATIC-TUBE SYSTEM NOTICE 1-6 (2000) INCORPORATED SPECIAL CHANGE (2000) INCORPORATED《气送管系统 加入了1-6(2000)注意事项以及(2000)的特别变更事项》.pdf_第3页
第3页 / 共14页
COE CEGS 14580-2000 PNEUMATIC-TUBE SYSTEM NOTICE 1-6 (2000) INCORPORATED SPECIAL CHANGE (2000) INCORPORATED《气送管系统 加入了1-6(2000)注意事项以及(2000)的特别变更事项》.pdf_第4页
第4页 / 共14页
COE CEGS 14580-2000 PNEUMATIC-TUBE SYSTEM NOTICE 1-6 (2000) INCORPORATED SPECIAL CHANGE (2000) INCORPORATED《气送管系统 加入了1-6(2000)注意事项以及(2000)的特别变更事项》.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、TESTPDF*DEPARTMENT OF THE ARMY CEGS-14580 (March 1989)U.S. ARMY CORPS OF ENGINEERS -SupersedingCEGS-14700 (May 1988)GUIDE SPECIFICATION FOR CONSTRUCTIONIncludes changes through Notice 6 (January 2000)Includes note relocation Special change (August 1995)Includes Text Adjustment Change (Section Refere

2、nces) (November 1998)Includes Special Change (Submittal Paragraph)(June/August 2000)Latest change indicated by CHG tags*SECTION TABLE OF CONTENTSDIVISION 14 - CONVEYING SYSTEMSSECTION 14580PNEUMATIC-TUBE SYSTEM03/89PART 1 GENERAL1.1 REFERENCES1.2 ELECTRICAL WORK1.3 SUBMITTALS1.4 DESIGN REQUIREMENTS1

3、.5 GENERAL REQUIREMENTS1.5.1 Standard Products1.5.2 Verification of Dimensions1.6 DELIVERY AND STORAGEPART 2 PRODUCTS2.1 CARRIER TUBING2.1.1 Tubing2.1.2 Bends2.1.3 Fittings2.2 POWER UNITS2.3 AUTOMATIC CENTRAL-CONTROL CENTER2.3.1 Operation of the System2.3.2 Control Program2.3.3 Computer Circuits and

4、 Keyboard2.3.3.1 Cathode Ray Tube2.3.3.2 Keyboard2.3.3.3 Printer2.3.3.4 Alarm Module2.4 STORAGE AREAS2.5 AUTOMATIC SWITCHING EQUIPMENT2.6 SUBSTATION EQUIPMENT2.6.1 Receiving UnitsSECTION 14580 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TES

5、TPDF2.6.2 Sending Units2.6.3 Carrier Storage Receptacle2.6.4 Station Control Panel2.6.4.1 Operating Controls and Indicators2.6.4.2 Non-operating Requirements2.6.5 Directory2.7 CARRIERS2.7.1 Access2.7.2 Carrier Inserts2.8 SYSTEM TESTERPART 3 EXECUTION3.1 INSTALLATION3.1.1 Sound Insulation3.1.2 Hanger

6、s and Supports3.1.3 Installation of Tubing3.1.4 Firewall Penetrations3.2 PAINTING AND FINISHING3.3 ACCESS PANELS3.4 ACOUSTIC COUPLER3.5 TESTS3.6 FRAMED INSTRUCTIONS3.7 MANUFACTURERS SERVICES3.7.1 Field Training- End of Section Table of Contents -SECTION 14580 Page 2Provided by IHSNot for ResaleNo re

7、production or networking permitted without license from IHS-,-,-TESTPDF*DEPARTMENT OF THE ARMY CEGS-14580 (March 1989)U.S. ARMY CORPS OF ENGINEERS -SupersedingCEGS-14700 (May 1988)GUIDE SPECIFICATION FOR CONSTRUCTIONIncludes changes through Notice 6 (January 2000)Includes note relocation Special cha

8、nge (August 1995)Includes Text Adjustment Change (Section References) (November 1998)Includes Special Change (Submittal Paragraph)(June/August 2000)Latest change indicated by CHG tags*SECTION 14580PNEUMATIC-TUBE SYSTEM03/89*NOTE: This guide specification covers the requirements for computer controll

9、ed pneumatic tube system. This guide specification is to be used in the preparation of project specifications in accordance with ER 1110-1-8155.Comments and suggestions on this guide specification are welcome and should be directed to the proponent of the specification. A listing of proponents, incl

10、uding their organization designation and telephone number, is at URL http:/www.hnd.usace.army.mil/techinfo/index.htm, and an electronic feedback page for submission of recommended changes is available at the same address. Use of electronic communication is encouraged.*PART 1 GENERAL1.1 REFERENCES*NO

11、TE: Issue (date) of references included in project specifications need not be more current than provided by the latest change (Notice) to this guide specification.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text b

12、y basic designation only.SECTION 14580 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TESTPDFAMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)ASTM A 123/A 123M (1997ae1) Zinc (Hot-Dipped Galvanized) Coatings on Iron and Steel ProductsNATIONAL

13、ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)NEMA MG 1 (1993; Rev 1; Rev 2; Rev 3; Rev 4) Motors and GeneratorsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 70 (1999) National Electrical Code1.2 ELECTRICAL WORKElectrical motor-driven equipment specified herein shall be provided complete with motors,

14、 motor starters and controls and shall comply with NEMA MG 1. Electrical equipment and wiring shall be in accordance with Section 16415 ELECTRICAL WORK, INTERIOR. Electrical characteristics shall be as indicated. Extension to equipment from junction box and all control wiring shall be under this sec

15、tion and shall comply with NFPA 70. Motor starters shall be provided under this section complete with properly sized thermal-overload protection in each phase and other appurtenances necessary for the motor control specified. Each motor shall be sized to drive the equipment at the specified capacity

16、 without exceeding the nameplate rating of the motor when operating at proper electrical system voltage. Control and protective or signal devices required for the operation specified and wiring required for controls and devices but not shown on the electrical plans, shall be provided herein.1.3 SUBM

17、ITTALS*NOTE: Submittals must be limited to those necessary for adequate quality control. The importance of an item in the project should be one of the primary factors in determining if a submittal for the item should be required.Indicate submittal classification in the blank space following the name

18、 of the item requiring the submittal by using “G“ when the submittal requires Government approval. Submittals not classified as “G“ will show on the submittal register as “Information Only“. For submittals requiring Government approval, a code of up to three characters should be used following the “

19、G“ designation to indicate the approving authority; codes of “RE“ for Resident Engineer approval, “ED“ for Engineering approval, and “AE“ for Architect-Engineer approval are recommended.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation ar

20、e for information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01330 SUBMITTAL PROCEDURES:SECTION 14580 Page 4Provided by IHSNot for ResaleNo reproduct

21、ion or networking permitted without license from IHS-,-,-TESTPDFSD-02 Shop DrawingsPneumatic-Tube System; _, _Detail drawings containing complete wiring and schematic diagrams and any other details required to demonstrate that the system has been coordinated and will properly function as a unit. Dra

22、wings shall show proposed layout and anchorage of equipment and appurtenances, and equipment relationship to other parts of the work including clearance for maintenance and operation.SD-03 Product DataPneumatic-Tube System; _, _Six _ copies of design manual consisting of manufacturers standard liter

23、ature. The design manual shall identify the operational requirements for the system and explain the theory of operation, design philosophy, and specific functions. A description of hardware and software functions, interfaces, and requirements shall be included for all system operating modes. The man

24、ual shall describe all equipment provided, including general description and specifications.Materials and Equipment; _, _A complete list of equipment and material, including manufacturers descriptive data and technical literature, performance charts and curves, catalog cuts, and installation instruc

25、tions.Spare Parts Data; _, _Spare parts data for each different item of materials and equipment specified, after approval of the detail drawings and not later than _ months prior to the date of beneficial occupancy. The data shall include a complete list of parts and supplies, with current unit pric

26、es and source of supply.Pneumatic-Tube System; _, _Diagrams, instructions, and other sheets proposed for posting.Tests; _, _Test plan and procedures, not later than _ days prior to the start of testing. The test plan and test procedures shall explain in detail, step-by-step, actions and expected res

27、ults to demonstrate compliance with the requirements of this specification, and the methods for simulating the necessary conditions of operation to demonstrate performance of the system.SD-06 Test ReportsTests; _, _Test reports in booklet form showing all field tests performed to adjust each compone

28、nt and all field tests performed to prove SECTION 14580 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TESTPDFcompliance with the specified performance criteria, upon completion of installation and testing of the installed system. Each test re

29、port shall indicate the final position of controls.SD-10 Operation and Maintenance DataPneumatic-Tube System; G, _Six _ complete copies of operation manual outlining the step-by-step procedures required for system startup, operation, and shutdown. The manuals shall include the manufacturers name, mo

30、del number, service manual, parts list, and brief description of all equipment and their basic operating features. Six _ complete copies of maintenance manual listing routine maintenance procedures, possible breakdowns and repairs, and troubleshooting guide. The manuals shall include piping layout,

31、equipment layout, simplified wiring and control diagrams of the system as installed. Operation and maintenance manuals shall be approved prior to the training course.1.4 DESIGN REQUIREMENTSThe pneumatic-tube system shall be computer controlled and designed with not less than _ separate zones interco

32、nnected to permit automatic unattended transmission of carriers from any station to any other station. System components shall be designed and located in such a manner that in the event of a defect occurring, components may readily be removed and replaced. Carriers shall be the full access type , ca

33、pable of handling 1000 ml I.V. bottles or 1000 ml I.V. bags. Other system characteristics shall be as follows:a. Future capacity of not less than _ stations without the need for modifications to the central control and existing station control.b. Each zone capable of serving not less than _ stations

34、 even though a fewer number may be indicated in a given zone at this time.c. Stations within a zone connected to the storage lanes via a single line and diverter unit. The computer shall control spacing, direction, storage, and path of the carriers.d. Destination selection by means of push buttons o

35、r rotary dials on the station control panel.e. Carriers taking the shortest route to their destinations. A central exchanger shall not be required. Carrier processing between zones shall be done through the central storage lanes.f. Carriers routed by means of diverters or in-line transfer units.g. C

36、arrier rejections indicated at the dispatching station for non-existing, signed-off, or malfunctioning station destinations. Reject station shall not be used.h. Failure of one station shall not interfere with the normal functioning of any other station. Failure of any diverter will shut down that se

37、ction of the system. Failure of an in-line SECTION 14580 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TESTPDFsensor except zero-level sensor shall not shut down that section of the system.i. Automatic sequencing of sending and receiving carr

38、iers.j. Each zone and the central storage lanes act independently with separate power units as required.k. Automatic recovery of a carrier will be required only after a transaction has been initiated and a failure occurs that prevents the completion. In such a case the carrier in process will be eit

39、her returned to its source station or processed to the destination station after the failure has been repaired and cleared.l. Selection of the shortest, most direct routing of all carriers to their destinations.m. Complete “route proofing“ of transaction paths before acceptance of the carrier to ass

40、ure all components in the routing are operating.n. Intra-zone transactions shall take the most direct path within the zone.o. Self-adjusting priority within the system to load balance according to traffic.p. Carriers may be positioned in senders simultaneously and destination selected on the station

41、 control panel.q. Carriers in transit at the time a power failure occurs shall be delivered to their selected destinations upon restoration of power.r. Processing of simultaneous, multiple transactions shall be directed to assure maximum operational efficiency of the system.s. Carriers in transit at

42、 the time of station sign-off shall be delivered to their destination.t. Carriers addressed to any non-existing or signed off station shall be rejected.u. Automatic time clock sign off to allow any station to be automatically signed-off.v. Preventive overload feature at station receiver. Carriers wi

43、ll not be dispatched to a station that is overloaded.w. Automatic redistribution of empty carriers to return empty carriers to the locations with the greatest need.x. Automatic purge by zone or system.y. Each completed transaction, alarm condition that occurs and sign off schedule automatically prin

44、ted out on printer.1.5 GENERAL REQUIREMENTSSECTION 14580 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TESTPDF1.5.1 Standard ProductsMaterials and equipment shall be the standard products of a manufacturer regularly engaged in the manufacture

45、 of the products and shall essentially duplicate items that have been in satisfactory use for at least 2 years prior to bid opening. Equipment shall be supported by a service organization that is, in the opinion of the Contracting Officer, reasonably convenient to the site.1.5.2 Verification of Dime

46、nsionsThe Contractor shall become familiar with all details of the work, verify all dimensions in the field, and shall advise the Contracting Officer of any discrepancy before performing the work.1.6 DELIVERY AND STORAGEAll equipment delivered and placed in storage shall be stored with protection from the weather, humid