1、February 2014 Translation by DIN-Sprachendienst.English price group 15No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).I
2、CS 81.040.20!%,BX“2093153www.din.deDDIN EN 15683-2Glass in building Thermally toughened soda lime silicate channel shaped safety glass Part 2: Evaluation of conformity/Product standard;English version EN 15683-2:2013,English translation of DIN EN 15683-2:2014-02Glas im Bauwesen Thermisch vorgespannt
3、es Kalknatron-Profilbau-Sicherheitsglas Teil 2: Konformittsbewertung/Produktnorm;Englische Fassung EN 15683-2:2013,Englische bersetzung von DIN EN 15683-2:2014-02Verre dans la construction Verre de silicate sodo-calcique profil de scurit tremp thermiquement Partie 2: valuation de la conformit/Norme
4、de produit;Version anglaise EN 15683-2:2013,Traduction anglaise de DIN EN 15683-2:2014-02www.beuth.deDocument comprises 37 pagesIn case of doubt, the German-language original shall be considered authoritative.01.14DIN EN 15683-2:2014-02 2 A comma is used as the decimal marker. Start of application I
5、t should be noted that, in Germany, CE conformity marking of construction products will be permitted once this standard has been listed in the Official Journal of the European Union and/or the Bundesanzeiger (German Federal Gazette) and from the date given therein. For further information, users of
6、this standard should refer to the websites of the European Commission or of the relevant building authority. National foreword This document (EN 15683-2:2013) has been prepared by Technical Committee CEN/TC 129 “Glass in building” (Secretariat: NBN, Belgium). The responsible German body involved in
7、its preparation was the Normenausschuss Bauwesen (Building and Civil Engineering Standards Committee), Working Committee NA 005-09-29 AA Glas im Bauwesen (SpA zu CEN/TC 129 und ISO/TC 160). EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15683-2 December 2013 ICS 81.040.20 English Version Glass
8、 in building - Thermally toughened soda lime silicate channel shaped safety glass - Part 2: Evaluation of conformity/Product standard Verre dans la construction - Verre de silicate sodo-calcique profil de scurit tremp thermiquement - Partie 2: valuation de la conformit/Norme de produit Glas im Bauwe
9、sen - Thermisch vorgespanntes Kalknatron-Profilbau-Sicherheitsglas - Teil 2: Konformittsbewertung/Produktnorm This European Standard was approved by CEN on 30 May 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European S
10、tandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (Eng
11、lish, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium,
12、 Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerlan
13、d, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Mem
14、bers. Ref. No. EN 15683-2:2013 EEN 15683-2:2013 (E) 2 Contents Page Foreword 4 1 Scope 5 2 Normative references 5 3 Terms and definitions . 6 4 Requirements . 6 4.1 Product description . 6 4.2 Conformity with the definition of thermally toughened soda lime silicate channel shaped safety glass 7 4.3
15、Determination of the performances of characteristics 7 4.3.1 Characteristics of thermally toughened soda lime silicate channel shaped safety glass . 7 4.3.2 Determination of characteristics of thermally toughened soda lime silicate channel shaped safety glass products 8 4.4 Durability 10 4.5 Dangero
16、us substances . 11 5 Evaluation of conformity . 11 5.1 General 11 5.2 Initial type testing of the product (see 5.1, b) 11 5.2.1 General 11 5.2.2 Initial type testing of thermally toughened soda lime silicate channel shaped safety glass 13 5.2.3 Initial type testing of characteristics performances .
17、15 5.3 Factory production control and inspection of samples in accordance with a prescribed test plan (see 5.1, a) 1) and 2) 15 5.4 Initial inspection of factory and of factory production control (see 5.1, a) 2) . 16 5.5 Continuous surveillance and assessment of the factory production control (see 5
18、.1, a) 3) . 16 6 Marking and labelling 17 6.1 General 17 6.2 Product marking 17 6.3 Product characteristics . 17 6.4 “Characteristic/performance identification paper“ 17 Annex A (normative) Factory production control 18 A.1 Factory production control requirements . 18 A.1.1 General 18 A.1.2 Organisa
19、tion . 18 A.1.3 Control system . 18 A.2 Marking . 19 A.3 Inspection and testing tables of thermally toughened soda lime silicate channel shaped safety glass production 19 A.3.1 Information to the Table A.1 . 19 A.3.2 Product control 20 A.3.3 Use of proxy testing 20 Annex B (informative) Tests for fa
20、ctory production control . 24 B.1 Fragmentation test 24 B.1.1 Requirements . 24 B.1.2 Test method 24 Annex C (informative) Provisions for voluntary involvement of third party(ies) 25 C.1 General 25 C.2 Voluntary tasks for third parties 25 DIN EN 15683-2:2014-02 EN 15683-2:2013 (E) 3 C.3 Marking and
21、labelling 25 Annex ZA (normative) Clauses of this European Standard addressing the provisions of EU Construction Products Directive . 26 ZA.1 Scope and relevant characteristics . 26 ZA.2 Procedure(s) for the attestation of conformity of thermally toughened soda lime silicate channel shaped safety gl
22、ass products . 28 ZA.2.1 System(s) of attestation of conformity 28 ZA.2.2 EC Certificate and Declaration of Conformity 31 ZA.3 CE marking and labelling 32 Bibliography 35 DIN EN 15683-2:2014-02 EN 15683-2:2013 (E) 4 Foreword This document (EN 15683-2:2013) has been prepared by Technical Committee CE
23、N/TC 129 “Glass in Building”, the secretariat of which is held by NBN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2014, and conflicting national standards shall be withdrawn at the lates
24、t by June 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the Eu
25、ropean Commission and the European Free Trade Association, and supports essential requirements of EU Directives. For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. EN 15683 is composed of the following parts: EN 15683-1, Glass in building The
26、rmally toughened soda lime silicate channel shaped safety glass Part 1: Definition and description EN 15683-2, Glass in building Thermally toughened soda lime silicate channel shaped safety glass Part 2: Evaluation of conformity/Product standard According to the CEN-CENELEC Internal Regulations, the
27、 national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia
28、, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 15683-2:2014-02 EN 15683-2:2013 (E) 5 1 Scope This European Standard covers the evaluation of conformity and the factory production co
29、ntrol of thermally toughened soda lime silicate channel shaped safety glass for use in buildings. This also includes requirements subject to regulation. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its appl
30、ication. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 356, Glass in building Security glazing Testing and classification of resistance against manual attack EN 410, Glass in building
31、 Determination of luminous and solar characteristics of glazing EN 572-1, Glass in building Basic soda lime silicate glass products - Part 1: Definitions and general physical and mechanical properties EN 572-7, Glass in building Basic soda lime silicate glass products Part 7: Wired or unwired channe
32、l shaped glass EN 673, Glass in building Determination of thermal transmittance (U value) Calculation method EN 1063, Glass in building Security glazing Testing and classification of resistance against bullet attack EN 1096-1, Glass in building Coated glass Part 1: Definitions and classification EN
33、1096-2, Glass in building Coated glass Part 2: Requirements and test methods for class A, B and S coatings EN 12600, Glass in building Pendulum test Impact test method and classification for flat glass EN 12758, Glass in building Glazing and airborne sound insulation Product descriptions and determi
34、nation of properties EN 12898, Glass in building Determination of the emissivity EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests EN 13501-2, Fire classification of construction products and building elements
35、 Part 2: Classification using data from fire resistance tests, excluding ventilation services EN 13501-5, Fire classification of construction products and building elements Part 5: Classification using data from external fire exposure to roofs tests EN 13541, Glass in building Security glazing Testi
36、ng and classification of resistance against explosion pressure EN 15683-1:2013, Glass in building Thermally toughened soda lime silicate channel shaped safety glass Part 1: Definition and description DIN EN 15683-2:2014-02 EN 15683-2:2013 (E) 6 3 Terms and definitions For the purpose of this documen
37、t, the terms and definitions given in EN 15683-1:2013 and the following apply. 3.1 initial type testing determination of the performance of a product (characteristic, durability), on the basis of either actual tests or other procedures (such as conventional, standardised, tabulated or general accept
38、ed values, standardised or recognised calculation methods, test reports when made available, ), in accordance with this document that demonstrates compliance with this document 3.2 test report document that covers the results of tests undertaken on a representative sample of the product from product
39、ion or on a prototype design of the product 3.3 product description document that details the relevant parameters, e.g. process conditions, structure, etc., for defining a product that complies with the standard and which includes specific reference(s) to characteristics that are modified by the pro
40、duction process 3.4 significant change variation in performance beyond the permitted tolerance for the characteristic 3.5 plank length of channel shaped glass 4 Requirements 4.1 Product description For conformity purposes, the thermally toughened soda lime silicate channel shaped glass manufacturer
41、is responsible for the preparation and maintenance of the product description. This description shall describe the product and/or product families. Disclosure of the product description shall be at the discretion of the thermally toughened glass manufacturer or his agent except in the case of regula
42、tory requirements. The description shall contain at least a normative part. The description may also contain an informative part, when the manufacturer foresees further development of the product. The normative part of the description shall contain the following minimum information: a reference to E
43、N 15683-1 and EN 15683-2 and all other standards with which the manufacturer claims compliance; the spectrophotometric properties and durability of coated glass, i.e. coated glass that conforms with EN 1096-1 and EN 1096-2, when those properties are changed, intentionally or unintentionally, by the
44、thermal toughening process. The definition of product families shall be consistent with the normative part of the product description. DIN EN 15683-2:2014-02 EN 15683-2:2013 (E) 7 The substitution of materials shall maintain the conformity with the product description. The substituting material can
45、be added to the product family and also the product description when compliance has been demonstrated. 4.2 Conformity with the definition of thermally toughened soda lime silicate channel shaped safety glass Products shall conform to the definition and fulfil the requirements of thermally toughened
46、soda lime silicate channel shaped safety glass as defined in EN 15683-1. 4.3 Determination of the performances of characteristics 4.3.1 Characteristics of thermally toughened soda lime silicate channel shaped safety glass 4.3.1.1 General The characteristics of thermally toughened soda lime silicate
47、channel shaped safety glass are those of the glass substrate (see 4.3.1.2). 4.3.1.2 Characteristics of channel shaped glass used for thermally toughened soda lime silicate channel shaped safety glass Planks shall be made of unwired channel shaped glass products according to EN 572-1 and EN 572-7. Th
48、e panes may be coated according to EN 1096-1 and EN 1096-2, and/or enamelled according to EN 15683-1. For the characteristics listed in Table 1, for thermally toughened soda lime silicate channel shaped safety glass, generally accepted values or calculated values shall be used. Since the majority of
49、 the characteristics of Table 1 are not changed significantly by the thermal toughening process they shall be used for thermally toughened soda lime silicate channel shaped safety glass. The exceptions shall be the characteristic bending strength fg,k and the resistance against sudden temperature changes and temperature differentials. DIN EN 15683-2:2014-02 EN 15683-2:2013 (E) 8 Table 1 Information on the characteristics of basic channel shaped glass, according to EN 572-1, used for the