1、September 2007DEUTSCHE NORM English price group 6No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 23.040.01; 91.140.60!
2、$I3Z“1381655www.din.deDDIN EN ISO 15875-2/A1Plastics piping systems for hot and cold water installations Crosslinked polyethylene (PE-X) Part 2: Pipes Amendment 1 (ISO 15875-2:2003/Amd 1:2007)English version of DIN EN ISO 15875-2/A1:2007-09Kunststoff-Rohrleitungssysteme fr die Warm- und Kaltwasserin
3、stallation Vernetztes Polyethylen (PE-X) Teil 2: Rohre nderung 1 (ISO 15875-2:2003/Amd 1:2007)Englische Fassung DIN EN ISO 15875-2/A1:2007-09ModifiesDIN EN ISO 15875-2:2004-03www.beuth.deDocument comprises 6 pages11.07DIN EN ISO 15875-2/A1:2007-09 2 National foreword This amendment has been prepared
4、 by Technical Committee CEN/TC 155 “Plastics piping systems and ducting systems” (Secretariat: NEN, the Netherlands), in collaboration with ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids”, Subcommittee SC 2 “Plastics pipes and fittings for water supplies” (Secretariat: S
5、NV, Switzerland). The responsible German body involved in its preparation was the Normenausschuss Wasserwesen (Water Practice Standards Committee), Technical Committee NA 119-04-06-05 GUA Kunststoffrohre in der Trinkwas-serversorgung; Warm- und Kaltwasserleitungen. EUROPEAN STANDARDNORME EUROPENNEEU
6、ROPISCHE NORMEN ISO 15875-2:2003/A1June 2007ICS 91.140.60; 23.040.20English VersionPlastics piping systems for hot and cold water installations -Crosslinked polyethylene (PE-X) - Part 2: Pipes - Amendment 1(ISO 15875-2:2003/Amd 1:2007)Systmes de canalisations en plastique pour lesinstallations deau
7、chaude et froide - Polythylne rticulKunststoff-Rohrleitungssysteme fr die Warm- undKaltwasserinstallation - Vernetztes Polyethylen (PE-X) -This amendment A1 modifies the European Standard EN ISO 15875-2:2003; it was approved by CEN on 9 June 2007.CEN members are bound to comply with the CEN/CENELEC
8、Internal Regulations which stipulate the conditions for inclusion of thisamendment into the relevant national standard without any alteration. Up-to-date lists and bibliographical references concerning suchnational standards may be obtained on application to the CEN Management Centre or to any CEN m
9、ember.This amendment exists in three official versions (English, French, German). A version in any other language made by translation under theresponsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the officialversions.CEN members are th
10、e national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland
11、and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN ISO 1587
12、5-2:2003/A1:2007: ETeil 2: Rohre - nderung 1 (ISO 15875-2:2003/Amd 1:2007)(PE-X) - Partie 2: Tubes - Amendement 1(ISO 15875-2:2003/Amd 1:2007)EN ISO 15875-2:2003/A1:2007 (E) 2 Foreword This document (EN ISO 15875-2:2003/A1:2007) has been prepared by Technical Committee CEN/TC 155 “Plastics piping sy
13、stems and ducting systems”, the secretariat of which is held by NEN, in collaboration with Technical Committee ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids”. This European Standard shall be given the status of a national standard, either by publication of an identical
14、text or by endorsement, at the latest by December 2007, and conflicting national standards shall be withdrawn at the latest by December 2007. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standa
15、rd: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN IS
16、O 15875-2:2003/A1:2007 (E) 3 Introduction In ISO 15875-2:2003, the base pipe is required to fulfil the dimensional requirements and the barrier is an “add on” giving to the finished product a wall thickness and outside diameter greater than stated in that part of ISO 15875. In some countries it is c
17、ommon practice that the finished product be required to fulfil the dimensional requirements of the standard. This situation creates a problem throughout the world due to different requirements in different countries. It illustrates the need to have a common procedure on the market for dealing with t
18、his matter. Amendment 1 to ISO 15875-2:2003 has been developed to clarify the requirements on dimensions and tolerances for barrier pipes and create a common procedure for designing and testing those pipes. EN ISO 15875-2:2003/A1:2007 (E) 4 Page 4, 6.1.3 Replace the subclause with the following: 6.1
19、.3 The values of outside diameter and/or wall thickness apply to the crosslinked polyethylene pipe and are exclusive of additional outside layers. For pipes with barrier layer1), the values of outside diameter and wall thickness may apply to the finished product, including the barrier layer, provide
20、d that the thickness of the outside barrier layer, including any adhesive layer, is 0,4 mm and the design calculation using the values of outside diameter and wall thickness of the base pipe (PE-X) meet the Scalc,maxvalues according to Table 1. The manufacturer shall state the dimensions and toleran
21、ces of the base pipe in his documentation when different from Tables 2 to 6 of this part of ISO 15875. NOTE For certification purposes, when a plastic barrier layer is embedded in the PE-X pipe wall, this construction is covered by this part of ISO 15875 until such time as the International Standard
22、s for such products (see Bibliographic references 7 to 10) are published. Page 13, Bibliography Add the following to the Bibliography: 7 ISO 21003-12), Multilayer piping systems for hot and cold water installations inside buildings Part 1: General 8 ISO 21003-22), Multilayer piping systems for hot a
23、nd cold water installations inside buildings Part 2: Pipes 9 ISO 21003-32), Multilayer piping systems for hot and cold water installations inside buildings Part 3: Fittings 10 ISO 21003-52), Multilayer piping systems for hot and cold water installations inside buildings Part 5: Fitness for purpose of the system 1) See ISO 15875-1:2003/Amd.1:2007.2) To be published.