1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: STDZNMGTdla.mil or Defense Supply Center Richmond (DSCR), ATTN: DSCR-VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616. AMSC N/A FSC 5940 INCH-POUN

2、D A-A-59559A 22 March 2007 SUPERSEDING A-A-59559 23 June 2000 COMMERCIAL ITEM DESCRIPTION POST, BINDING, ELECTRICAL, WATERPROOF (INSULATED), DUAL O-RING SEAL The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. This commer

3、cial item description (CID) covers an insulated electrical binding post used as a wiring termination on terminal boards and test set panels. 2. CLASSIFICATION. The electrical binding post shall be classified and identified by the types in accordance with the characteristics specified in table I. The

4、 selected types of products to be supplied shall be specified in the acquisition order (see 7.3(b). TABLE I. Electrical binding post dimensions. Dimensions Type Cap color A1 B1 (0.015)C1 (+0.016/-0.049) I Black 2.000 (max.) 1.950 (min.) 1.000 0.719 II Red 2.000 (max.) 1.950 (min.) 1.000 0.719 1See f

5、igure 1. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59559A 2 3. SALIENT CHARACTERISTICS 3.1 Components. The electrical binding post shall be similar to the one shown in figure 1. The product shall consist of the binding post, insulated sprin

6、g-loaded cap and mounting washers, o-rings, and all mounting hardware. 0.0620.125SOLDER DIP0.125HEX NUTNO. 10-32UNF-2B0.0000.003DEPRESS CAP TOINSERT WIRE(SEE NOTE 2)0.062 MAX WIREACCOMMODATION“O“ RINGS 0.302 (PANEL THICKNESS 0.062 TO 0.125 INCHES)SEE NOTE 2SPLITLOCK WASHERNO. 10-32UNF-2APOST 0.5830.

7、010SEE NOTE 2NO. 10 MED, BRASS WASHERACBNOTES: 1. The figure depicts only general characteristics and is not intended to limit specific manufacturing processes. 2. This is the insulated portion. 3. Dimensions (listed in table I) are in inches. Tolerance is 0.015 inch unless otherwise shown. FIGURE 1

8、. Binding post configuration. 3.2 Materials. 3.2.1 Metal. Unless specified otherwise in the acquisition order (see 7.3(c), the current-carrying portions of the binding post shall be brass conforming to the requirements of the ASTM B16/B 16M, “Standard Specification for Free-Cutting Brass Rod, Bar an

9、d Shapes for Use in Screw Machines“. 3.2.2 Finish. Unless otherwise specified in the acquisition order (see 7.3(d), metal portions of the binding post shall be nickel plated in accordance with the SAE AMS-QQ-N-290, “Nickel Plating (Electrodeposited)“. 3.2.2.1 Solder coating. Unless otherwise specifi

10、ed in the acquisition order (see 7.3(e), the solder terminal end shall be hot solder dipped/coated. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59559A 3 3.2.3 Insulation. The material used for the insulated portions of the binding post shall

11、be specified in the acquisition order (see 7.3(f). The insulated washers of the binding post shall be natural/milky white unless otherwise specified in the acquisition order (see 7.3(g). The insulated cap shall be the color listed in table I. 3.2.4 Cap and cap spring. The cap shall be insulated and

12、non-removable. The strength of the cap spring shall permit the cap to be depressed using a force of 5 to 10 pounds. 3.3 Dielectric withstanding voltage. When specified in the acquisition order (see 7.3(h), the insulated binding post shall be tested in accordance with method 301 of MIL-STD-202, “Test

13、 Method Standard for Electronic and Electrical Component Parts“. The following details and exceptions shall apply: a. The binding post shall be mounted on a 0.125 inch thick bare metal test mount. The binding post shall be mounted with insulators and o-rings by applying a torque of 10 2 inch-pounds.

14、 b. The magnitude of the test voltage shall be 1,200 VAC RMS. The harmonic content of the voltage shall not exceed 0.50 percent of the fundamental waveform. c. The duration of application of test voltage shall be 1 minute 5 seconds. d. The test voltage shall be applied between the conductor accommod

15、ation and the metal test mount. e. The binding post shall show no evidence of damage, arcing, or breakdown after application of the test voltage. 3.4 Contact resistance. When specified in the acquisition order (see 7.3(i), the binding post contact resistance shall be tested as follows: a. A solid AW

16、G size 16 copper conductor shall be inserted in the contact cavity. b. A test current of 1 ampere shall be passed through the contact. c. Contact resistance shall be determined by measuring the potential drop between the extreme terminal end of the binding post and the copper conductor. d. The poten

17、tial drop shall not be greater than 0.002 V. 3.5 Solderability of solder terminal end. When specified in the acquisition order (see 7.3(j), the solderability of the binding post solder terminal end shall be tested in accordance with method 208 of MIL-STD-202. 3.6 Insulation resistance. When specifie

18、d in the acquisition order (see 7.3(k), the binding post insulation resistance shall be tested in accordance with method 302 of MIL-STD-202. The following details shall apply: a. Test condition A. b. The points of measurement shall be between two mutually insulated portions. c. The insulation resist

19、ance shall not be less than 1,000 megohms. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59559A 4 3.7 Panel seal. When specified in the acquisition order (see 7.3(l), the binding post panel seal shall be tested as follows: a. The contact end of

20、 the binding post shall be immersed in tap water to a depth equivalent to six feet for a minimum of 24 hours. b. The binding post shall be examined for leakage through the mounting hole. There shall be no visible leakage. 3.8 Conductor retention. When specified in the acquisition order (see 7.3(m),

21、conductor retention shall be tested as follows: a. The assembled mounting post shall be mounted on a test panel. b. A test bar, 0.062 inch diameter drill rod, 3 inches long, closed at one end with 1/4 inch diameter loop bent so that its center is common to the axis of the bar, shall be heat treated

22、to a hardness of 45-50 on the Rockwell “C“ scale as defined in ASTM E 18, “Standard Test Methods for Rockwell Hardness and Rockwell Superficial Hardness of Metallic Materials“. This bar shall be free from burrs and have a 32 micro-finish (minimum). c. The test bar shall be inserted between the bindi

23、ng post jaws allowing 1/2 inch to project from the free end. d. Attach one end of a spring scale to the loop on the bar and apply a pull force of approximately 3 pounds to the bar through the scale along the axis of the bar. e. Gradually increase the force to 9.5 pounds 0.5 pounds. f. There shall be

24、 no breakage of the binding post and no slippage of the test bar. 4. REGULATORY REQUIREMENTS 4.1 Recovered materials. The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with paragraph 23.403 of the Federal Acquisition Regulation (FAR). 5.

25、 PRODUCT CONFORMANCE PROVISIONS 5.1 Product conformance. The products provided shall meet the salient characteristics of this CID, conform to the producers own drawings, specifications, standards, and quality assurance practices, and be the same product offered for sale in the commercial marketplace

26、. The government reserves the right to require proof of such conformance. 5.2 Market acceptability. The product offered must have been previously sold either to the government or on the commercial market. 6. PACKAGING 6.1 Preservation, packing, and marking. Preservation, packing, and marking shall b

27、e as specified in the acquisition order (see 7.3(n). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59559A 5 7. NOTES 7.1 Part or identification number (PIN). The following PIN procedure is for government purposes and does not constitute a requi

28、rement for the contractor. 7.2 Sources of documents. 7.2.1 FAR. The FAR may be obtained from the Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954. Electronic copies of FAR documents may be obtained from http:/www.arnet.gov/far/. 7.2.2 Military specifications and standards. Cop

29、ies of military specifications and standards may be obtained from Standardization Documents Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094. Electronic copies of military specifications and standards may be obtained from http:/assist.daps.dla.mil. 7.2.3 ASTM standards. Copie

30、s of ASTM standards may be obtained from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. Electronic copies of ASTM standards may be obtained from http:/www.astm.org/. 7.2.4 SAE standards. Copies of SAE standards may be obtained from SAE International, 400

31、Commonwealth Drive, Warrendale, PA 15096-0001. Electronic copies of SAE standards may be obtained from http:/www.sae.org/. 7.3 Ordering data. The acquisition order should specify the following: a. CID document number, revision, and CID PIN. b. Type required (see 2). c. Current-carrying material, if

32、different (see 3.2.1). d. Binding post finish, if different (see 3.2.2). e. Solder terminal end finish, if different (see 3.2.2.1). f. Insulation material (see 3.2.3). g. Insulated washer color, if different (see 3.2.3). h. Dielectric withstanding voltage test, if required (see 3.3). i. Contact resi

33、stance test, if required (see 3.4). j. Solderability test, if required (see 3.5). k. Insulation resistance test, if required (see 3.6). l. Panel seal test, if required (see 3.7). m. Conductor retention test, if required (see 3.8). n. Preservation, packing, and marking (see 6.1). Type 1 = type I (see

34、 table I) Type 2 = type II (see table I) AA59559 - X CID number Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59559A 6 7.4 Subject term (key word) listing. spring-loaded cap terminal board test set panels wiring termination MILITARY INTERESTS:

35、CIVIL AGENCY COORDINATING ACTIVITY: Custodians: Army - CR Navy - SH Air Force - 11 GSA - FSS Review Activities: Army - AR, AT, MI Navy - AS, MC, OS Air Force - 99 Preparing Activity: DLA - GS2 (Project 5940-2006-002) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-