1、REVISIONS LTR DESCRIPTION DATE APPROVED Requirements of DSCC drawing 84148 are applicable. Prepared in accordance with ASME Y14.100 REV PAGE REV REV STATUS OF PAGES PAGE 1 2 3 4 5 6 PREPARED BY PMIC G Ron Gary DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43216-5000 CHECKED BY Lee Surowiec APPROVED
2、 BY Richard Taylor TITLE CONNECTOR, RECEPTACLE, ELECTRICAL, COAXIAL, RADIO FREQUENCY, STRIPLINE, SERIES BMA (PIN CONTACT), FLANGE MOUNTED, EXTENDED DIELECTRIC. SIZE CAGE CODE 037Z3 DWG. NO. 04016 Original date of drawing 30 June 2004 A REV PAGE 1 OF 5 AMSC N/A 5935-E743 Provided by IHSNot for Resale
3、No reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 037Z3 04016 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV PAGE 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. All undimensioned pictoria
4、l configurations are for reference purposes only. 4. Number 2 screws are suggested for mounting. 5. Series BMA interface in accordance with MIL-STD-348, pin contact. FIGURE 1. Series BMA, 4-hole flange mount receptacle, .250 extended dielectric. Provided by IHSNot for ResaleNo reproduction or networ
5、king permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 037Z3 04016 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV PAGE 3 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. All undimensioned pictorial configurations are for
6、reference purposes only. 4. Number 2 screws are suggested for mounting. 5. Series BMA interface in accordance with MIL-STD-348, pin contact. FIGURE 1. Series BMA, 4-hole flange mount receptacle, .330 extended dielectric. Provided by IHSNot for ResaleNo reproduction or networking permitted without li
7、cense from IHS-,-,-SIZE CAGE CODE DWG NO. 037Z3 04016 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV PAGE 4 ENGINEERING DATA: Nominal impedance: 50 ohms. Frequency range: 2 - 22 GHz. (Connector performance only, frequency range is dependent on cable used.) Voltage rating: 500 V rms at
8、 sea level. 125 V rms at 70,000 feet. Temperature rating: -65C to +105C. REQUIREMENTS: Requirements of drawing 84148 is applicable. Dimensions and configuration: See figures 1, 2 and MIL-STD-348. Force to engage and disengage: Torque: Not applicable. Longitudinal force: Not applicable. Radial misali
9、gnment - Not applicable. Axial misalignment - Not applicable. Coupling Proof Torque - Not applicable. Permeability of non-magnetic materials - Applicable. Hermetic seal: Not applicable. Leakage (pressurized connectors): Not applicable. Insulation resistance: In accordance with EIA 364-021; 5,000 meg
10、ohms minimum. Center contact retention: Axial force: 6 pounds, minimum. Torque: 4 inch-ounces, minimum. Voltage standing wave ratio (VSWR): 1.35 + .01 F (GHz), maximum. Test frequency: From .5 to 22 GHz. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-
11、,-SIZE CAGE CODE DWG NO. 037Z3 04016 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV PAGE 5 Moisture resistance: Method 106, MIL-STD-202. No measurements at high humidity. Insulation resistance shall be at least 200 megohms within 5 minutes after removal from humidity. Contact resistan
12、ce (in milliohms, maximum): Initial After environment Center contact: 3.0 4.0 Outer contact: 2.0 Not applicable Dielectric withstanding voltage at sea level: In accordance with EIA 364-020 test condition I. Test voltage: 1,500 Vrms. Thermal shock: Method 107, test condition A, MIL-STD-202, except te
13、st high temperature shall be +85C. Barometric pressure (reduced): Not applicable. RF high potential withstanding voltage: At a frequency between 5 to 7.5 MHz. Leakage current: Not applicable. RF voltage - 1,000 Vrms Cable retention force: Not applicable. Coupling mechanism retention force: Not appli
14、cable. RF leakage: Not applicable. RF transmission loss: .07 F,(tested 2 - 18 GHz, F in GHz). Part or Identifying Number (PIN): See table I. TABLE I. Part number and characteristics. Part no. Connector figure no. Characteristics 04016ZSG-1 1 4 hole flange receptacle. .050 diameter terminal for .250
15、thick panel. 04016ZSG-2 2 4 hole flange receptacle. .050 diameter terminal for .330 thick panel. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 037Z3 04016 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV PAGE 6 A
16、pproved sources of supply are listed herein. Additional sources will be added as they become available. The vendors listed on the requirements drawing have agreed to this drawing and a certificate of compliance has been submitted to DSCC-VAI. DSCC drawing PIN 1/ Vendor CAGE number Vendor reference P
17、IN 04016ZSG-1 SF1755-6109 04016ZSG-2 95077 SF1755-6110 1/ Parts must be purchased to this DSCC PIN to assure that all performance requirements and tests are met. Vendor CAGE Vendor Name and Number address 95077 S/V Microwave, Inc. 2400 Centrepark West Dr. WPB, Fl 33409 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-