1、AMSC N/A FSC 6145 MIL-DTL-13777/6C 20 July 2011 SUPERSEDING MIL-C-13777/6B 1 September 1966 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL 60, 65, AND 78 CONDUCTORS This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements fo
2、r acquiring the product described herein shall consist of this specification sheet and MIL-DTL-13777. REQUIREMENTS: Dimensions and configuration: See applicable figure and design data for the following cable types specified in table I. Design data is specified in table II. TABLE I. Cable types. 6013
3、30 601495S 601665S 601734S 601845S 601931S 651125 782166S TABLE II. Design data. Design data Type designation 601330 601495S 601931S Figure number 1 2 1 Total wires 60 60 60 Number of conductors & AWG # 60/#18 51/#18 9/#18S 60/#18S Insulation Minimum average thickness 0.015” 0.015” 0.015” Spark test
4、 voltage 3000 3000 3000 Inspection test voltage 1500 1500 1500 Cabling Layer 1 Filler Filler Filler Layer 2 (a) Number of wires 6 6 6 (b) AWG # #18 #18 #18S (c) Maximum lay Layer 3 (a) Number of wires 12 9 12 (b) AWG # #18 #18S #18S (c) Maximum lay Layer 4 (a) Number of wires 18 20 18 (b) AWG # #18
5、#18 #18S (c) Maximum lay Layer 5 (a) Number of wires 24 25 24 (b) AWG # #18 #18 #18S (c) Maximum lay 9.00” 12.00” 10.00” Sheath Number of layers 2 2 2 Total thickness minimum 0.141” 0.141” 0.188” Minimum OD cable 1.300” 1.470” 1.881” Maximum OD cable 1.360” 1.520” 1.981” See notes at end of table. I
6、nactive for new design after 1 June 1998. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/6C 2 TABLE II. Design data Continued. Design data Type designation 601665S1/,2/ 601734S3/,4/,5/ 601845S6/,7/,8/,9/ 651125 Figure number
7、 5 4 3 6 Total wires 60 60 60 65 Number of conductors & AWG # 65/#20 Insulation Minimum average thickness 0.015” 0.015” 0.015” 0.015” Spark test voltage 3000 3000 3000 3000 Inspection test voltage 1500 1500 1500 1500 Cabling Layer 1 Filler Filler Filler Filler in center (a) Number of wires 8 (b) AWG
8、 # #20 (c) Maximum lay Layer 2 (a) Number of wires 13 (b) AWG # #20 (c) Maximum lay Layer 3 (a) Number of wires 15/#18S 20 19 (b) AWG # #20 (c) Maximum lay Layer 4 (a) Number of wires 31/#18 25 (b) AWG # #20 (c) Maximum lay 11.00” 11.50” 13.00” Sheath Number of layers 2 2 2 2 Total thickness minimum
9、 0.156” 0.156” 0.109” 0.098” Minimum OD cable 1.615” 1.684” 1.820” 1.100” Maximum OD cable 1.715” 1.784” 1.870” 1.150” See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/6C 3 TABLE II. Design data Continued. Desi
10、gn data Type designation 782166S Figure number 7 Total wires 78 Number of conductors & AWG # 64/#20 4/#20S 2/#14 2/#8 6/#4 Insulation 0.018” Minimum average thickness 0.015” 0.025” 0.063” Spark test voltage 3000 Inspection test voltage 1500 1800 2500 3500 Cabling Minimum average thickness Layer 1 Fi
11、ller Layer 2 (a) Number of wires 2 6 12 (b) AWG # #14 #4 4/#20S (c) Maximum lay 8 Layer 3 (a) Number of wires 66 (b) AWG # 2/#8 64/#20 (c) Maximum lay 12.00” Sheath Number of layers 2 Total thickness minimum 0.183” Minimum OD cable 2.116” Maximum OD cable 2.216” Maximum weight (lbs./1000ft.) 2770 1/
12、 Number of conductors and AWG# for 601665S: 35/#18, 5 Pairs, Twisted & Shielded, 15/#18S. 2/ Number of wires for layer 2 of 601665S: 5 Pairs, Twisted, & Shielded, 4/#18. 3/ Number of conductors and AWG# for 601734S: 20/#18, 20 Pairs, Twisted, & Shielded. 4/ Number of wires layer 2 for 601734S: 6 Pai
13、rs. Twisted, & Shielded. 5/ Number of wires layer 4 for 601734S: 14 Pairs. Twisted, & Shielded. 6/ Number of conductors and AWG# for 601845S: 20 Pairs, Twisted & Shielded, 20 Single Shielded. 7/ Number of wires for layer 2 of 601845S: 5 Pairs, Twisted & Shielded, 3 Singles Shielded. 8/ Number of wir
14、es for layer 3 of 601845S: 17 Shielded. 9/ Number of wires for layer 4 for 601845S: 15 Pairs, Twisted, & Shielded. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/6C 4 NOTE: Double circle indicates shielded conductors. FIGURE 1. Cable t
15、ypes (601330, 601931S). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/6C 5 NOTE: Double circle indicates shielded conductors. FIGURE 2. Cable type (6014958). Provided by IHSNot for ResaleNo reproduction or networking permitted without
16、 license from IHS-,-,-MIL-DTL-13777/6C 6 NOTE: Double circle indicates shielded conductors. FIGURE 3. Cable type (601845S). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/6C 7 NOTE: Double circle indicates shielded conductors. FIGURE 4
17、. Cable type (6017348). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/6C 8 NOTE: Double circle indicates shielded conductors. FIGURE 5. Cable type (601665S). Provided by IHSNot for ResaleNo reproduction or networking permitted without
18、 license from IHS-,-,-MIL-DTL-13777/6C 9 FIGURE 6. Cable type (651125). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/6C 10 NOTE: Double circle indicates shielded conductors. FIGURE 7. Cable type (782166S). Provided by IHSNot for Resa
19、leNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/6C 11 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issues due to the extensiveness of the changes. Referenced documents. This documen
20、t references MIL-DTL-13777. CONCLUDING MATERIAL Custodians: Preparing activity: Army AR DLA - CC Navy SH Air Force 85 (Project 6145-2011-009) DLA CC Review activities: Army AT, CR, CR4, MI Navy MC Note: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information using the Assist Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-