DLA MIL-DTL-24646 11 B-2008 FUSE BOXES FEEDER DISTRIBUTION WITH SWITCHES WATERTIGHT (3 FEET) 125 VOLTS ALTERNATING CURRENT SINGLE AND THREE PHASE BUSES SINGLE AND DOUBLE FEEDERS SI .pdf

上传人:周芸 文档编号:690223 上传时间:2018-12-30 格式:PDF 页数:10 大小:397.77KB
下载 相关 举报
DLA MIL-DTL-24646 11 B-2008 FUSE BOXES FEEDER DISTRIBUTION WITH SWITCHES WATERTIGHT (3 FEET) 125 VOLTS ALTERNATING CURRENT SINGLE AND THREE PHASE BUSES SINGLE AND DOUBLE FEEDERS SI .pdf_第1页
第1页 / 共10页
DLA MIL-DTL-24646 11 B-2008 FUSE BOXES FEEDER DISTRIBUTION WITH SWITCHES WATERTIGHT (3 FEET) 125 VOLTS ALTERNATING CURRENT SINGLE AND THREE PHASE BUSES SINGLE AND DOUBLE FEEDERS SI .pdf_第2页
第2页 / 共10页
DLA MIL-DTL-24646 11 B-2008 FUSE BOXES FEEDER DISTRIBUTION WITH SWITCHES WATERTIGHT (3 FEET) 125 VOLTS ALTERNATING CURRENT SINGLE AND THREE PHASE BUSES SINGLE AND DOUBLE FEEDERS SI .pdf_第3页
第3页 / 共10页
DLA MIL-DTL-24646 11 B-2008 FUSE BOXES FEEDER DISTRIBUTION WITH SWITCHES WATERTIGHT (3 FEET) 125 VOLTS ALTERNATING CURRENT SINGLE AND THREE PHASE BUSES SINGLE AND DOUBLE FEEDERS SI .pdf_第4页
第4页 / 共10页
DLA MIL-DTL-24646 11 B-2008 FUSE BOXES FEEDER DISTRIBUTION WITH SWITCHES WATERTIGHT (3 FEET) 125 VOLTS ALTERNATING CURRENT SINGLE AND THREE PHASE BUSES SINGLE AND DOUBLE FEEDERS SI .pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、AMSC N/A FSC 5920 INCH-POUND MIL-DTL-24646/11B 29 October 2008 SUPERSEDING MIL-DTL-24646/11A 17 May 2002 DETAIL SPECIFICATION SHEET FUSE BOXES, FEEDER DISTRIBUTION, WITH SWITCHES, WATERTIGHT (3 FEET), 125 VOLTS, ALTERNATING CURRENT, SINGLE AND THREE PHASE BUSES, SINGLE AND DOUBLE FEEDERS, SINGLE PHA

2、SE BRANCHES, 0-30 AMPERE MIDGET FUSES, AND SNAP SWITCHES, SYMBOLS 645, 645.1, 649.1 AND 650.1 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and

3、 MIL-DTL-24646. FIGURE 1. Fuse box assembly, typical. Item No. 01, 02, 03, 04 (Symbol 649.1 shown) NOTES: 1. Dimensions are in inches. 2. Unless otherwise specified herein, tolerances shall be as follows: Two place decimals - plus or minus 0.02. Three place decimals - plus or minus 0.005.Provided by

4、 IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24646/11B 2 DIMENSIONS (REF) SYMBOL NO A B C 645 16.38 13.38 4.62 645.1 16.38 13.38 4.62 649.1 16.38 13.38 4.62 650.1 16.38 15.38 4.62 FIGURE 2. Enclosure, overall dimensions. Item No. 05, 06, 07 (Symbols

5、645, 645.1, 649.1, and 650.1) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24646/11B 3 DIMENSIONS SYMBOL NO A B 645 11.44 5.72 645.1 11.44 5.72 649.1 11.44 5.72 650.1 13.44 6.72 FIGURE 3. Mounting dimensions, ref. (Symbols 645, 645.1, 649.

6、1, 650.1) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24646/11B 4 SIDE VIEW FIGURE 4. Cover assembly, typical. (Symbols 645, 645.1, 649.1, and 650.1) 1.121.125.005.00BOTTOM VIEW Provided by IHSNot for ResaleNo reproduction or networking p

7、ermitted without license from IHS-,-,-MIL-DTL-24646/11B 5 FIGURE 5. Fuse cover assembly, typical. (Symbols 645, 645.1, 649.1 and 650.1) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24646/11B 6 DIMENSIONS (MAX) SYMBOL NO A B 645. 12.75 5.88

8、 645.1 12.75 5.88 649.1 12.75 5.88 650.1 12.75 10.75 FIGURE 6. Fuse block assembly, typical. Item No. 09, 10, 11, 12 (Symbols 645, 645.1, 649.1 and 650.1) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24646/11B 7 A. Four single-phase branch

9、es, B. Four single-phase branches, single feeder (Symbol 645) Double feeder (Symbol 645.1) C. Four single-phase branches D Eight single-phase branches (Symbol 649.1) (Symbol 650.1) FIGURE 7. Wiring diagrams. Item No. 09, 10, 11, 12 Provided by IHSNot for ResaleNo reproduction or networking permitted

10、 without license from IHS-,-,-MIL-DTL-24646/11B 8 REQUIREMENTS Symbol numbers: See table I. Design: Electrical rating: 125 volts alternating current, 0-10 ampere, 60 hertz. Dimensions and configuration: See figures 1, 2, 3, 4, 5 and 6. Wiring diagrams: See figure 7. Mounting dimensions: See figure 3

11、 Degree of enclosure: Watertight (3 feet). Nonmagnetic enclosure: Nonmagnetic enclosures shall be brass in accordance with MIL-E-24142. Attaching hardware shall be nonmagnetic and shall have a magnetic permeability not greater than 2.0. Designation and marking: See MIL-DTL-24646. Parts: The parts l

12、isted in table II and specified in MIL-DTL-24646 shall be used in the construction of the fuse boxes specified herein. General information: Military part numbers and general information are as specified in table I. TABLE I. Military part numbers and general information. Supersedes Military part no.

13、Symbol no. Weight in pounds No. of circuits Feeder MCM Branch MCM Fuse size Bus bar size Drawing no. Type M24646/11- 001 645 26.8 4 14 4 midget 0-30A 0.62 x 0.12 9-S-74196 18-A M24646/11- 002 645.1 26.8 4 14 4 midget 0-30A 0.62 x 0.12 9-S-74196 18-B M24646/11- 003 649.1 28.2 4 14 4 midget 0-30A 0.62

14、 x 0.12 9-S-74197 D-12A M24646/11- 004 650.1 36.2 8 14 4 midget 0-30A 0.62 x 0.12 9-S-74201 22-A Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24646/11B 9 TABLE II. Parts list. QTY M /- Item no. 1/ Description 001 002 003 004 Material/ spec

15、ification Remarks 01 Fuse box assembly (sym 645) - MIL-DTL-24646/11 See figure 1 02 Fuse box assembly (sym 645.1) - MIL-DTL-24646/11 See figure 1 03 Fuse box assembly (sym 649.1 - MIL-DTL-24646/11 See figure 1 04 Fuse box assembly (sym 650.1) - MIL-DTL-24646/11 See figure 1 05 2/ Enclosure (10 x 13

16、x 3) 1 1 1 4/ M24142/6-004 See figures 2 and 4 06 2/ Enclosure (12 x 13 x 3) 1 4/ M24142/6-008 See figures 2 and 4 07 Fuse cover assembly 1 1 1 1 MIL-DTL-24646/11 See figure 5 08 Wiring diagram 1 MIL-E-2036 See figure 7 09 Wiring diagram 1 MIL-E-2036 See figure 7 10 Wiring diagram 1 MIL-E-2036 See f

17、igure 7 11 Wiring diagram 1 MIL-E-2036 See figure 7 12 Fuse clip (midget 30A) 16 16 16 32 A-A-55507/1-04 N/A 13 Snap switch 4 4 4 8 M15291/3-002 N/A 14 Identification plate 1 1 1 1 Brass, ASTM B36/B36M B121.B121M N/A 15 Information plate 4 4 4 8 Brass, ASTM B36/B36M B121.B121M See figures 2 16 Switc

18、h information plate 3/ 4 4 4 8 Brass, ASTM B36/B36M B121.B121M See figures 2 1/ Item numbers after the figure titles are the same as the item numbers shown in this table. 2/ Enclosure is same as MIL-E-24142/6, except for inside depth which is 3 inches instead of 5 inches shown. 3/ As an option, the

19、switch information (“OFF”) may be metal stamped onto the covers, in lieu of being placed on an information plate. 4/ Enclosures shall be furnished with flat cover. Referenced documents. In addition to MIL-DTL-24646, this document references the following: MIL-E-2036 MIL-E-24142/6 ASTM B36/B36M ASTM

20、B121/B121M Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24646/11B 10 The margins of this specification sheet are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only an

21、d the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Custodian: Pre

22、paring activity: Navy - SH DLA - CC DLA - CC (Project 5920-2008-027) NOTE: the activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM D3343-2005(2010) Standard Test Method for Estimation of Hydrogen Content of Aviation Fuels《航空燃料氢含量估算的标准试验方法》.pdf ASTM D3343-2005(2010) Standard Test Method for Estimation of Hydrogen Content of Aviation Fuels《航空燃料氢含量估算的标准试验方法》.pdf
  • ASTM D3343-2005(2015) Standard Test Method for Estimation of Hydrogen Content of Aviation Fuels《评定航空燃料氢含量的标准试验方法》.pdf ASTM D3343-2005(2015) Standard Test Method for Estimation of Hydrogen Content of Aviation Fuels《评定航空燃料氢含量的标准试验方法》.pdf
  • ASTM D3343-2016 Standard Test Method for Estimation of Hydrogen Content of Aviation Fuels《估算航空燃料氢含量的标准试验方法》.pdf ASTM D3343-2016 Standard Test Method for Estimation of Hydrogen Content of Aviation Fuels《估算航空燃料氢含量的标准试验方法》.pdf
  • ASTM D3344-1990(2005) Standard Test Method for Total Wax Content of Corrugated Paperboard《波纹纸板总载蜡量的标准试验方法》.pdf ASTM D3344-1990(2005) Standard Test Method for Total Wax Content of Corrugated Paperboard《波纹纸板总载蜡量的标准试验方法》.pdf
  • ASTM D3344-1990(2010) Standard Test Method for Total Wax Content of Corrugated Paperboard《波纹面的纸板的总载蜡量的标准试验方法》.pdf ASTM D3344-1990(2010) Standard Test Method for Total Wax Content of Corrugated Paperboard《波纹面的纸板的总载蜡量的标准试验方法》.pdf
  • ASTM D3344-1990(2015) Standard Test Method for Total &x2009 Wax &x2009 Content &x2009 of &x2009 Corrugated &x2009 Paperboard《波纹纸板总载蜡量的标准试验方法》.pdf ASTM D3344-1990(2015) Standard Test Method for Total &x2009 Wax &x2009 Content &x2009 of &x2009 Corrugated &x2009 Paperboard《波纹纸板总载蜡量的标准试验方法》.pdf
  • ASTM D3345-1974(1999) Standard Test Method for Laboratory Evaluation of Wood and Other Cellulosic Materials for Resistance to Termites《木材及其他纤维素材料防白蚁破坏的实验室评定方法》.pdf ASTM D3345-1974(1999) Standard Test Method for Laboratory Evaluation of Wood and Other Cellulosic Materials for Resistance to Termites《木材及其他纤维素材料防白蚁破坏的实验室评定方法》.pdf
  • ASTM D3345-2008 Standard Test Method for Laboratory Evaluation of Wood and Other Cellulosic Materials for Resistance to Termites《木材及其他纤维素材料防白蚁破坏的实验室评定试验方法》.pdf ASTM D3345-2008 Standard Test Method for Laboratory Evaluation of Wood and Other Cellulosic Materials for Resistance to Termites《木材及其他纤维素材料防白蚁破坏的实验室评定试验方法》.pdf
  • ASTM D3345-2017 Standard Test Method for Laboratory Evaluation of Solid Wood for Resistance to Termites《固体木材对白蚁耐性的实验室评价的标准试验方法》.pdf ASTM D3345-2017 Standard Test Method for Laboratory Evaluation of Solid Wood for Resistance to Termites《固体木材对白蚁耐性的实验室评价的标准试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1