1、 DETAIL SPECIFICATION SHEET CONNECTOR, ELECTRICAL CIRCULAR, COVER, PROTECTIVE, PLUG, SERIES III, METRIC This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification

2、 sheet and MIL-DTL-38999. STYLE R FIGURE 1. Protective cover, plug, all classes. AMSC N/A FSC 5935 MIL-DTL-38999/32E 4 October 2013 SUPERSEDING MIL-DTL-38999/32D 30 May 2008 METRIC Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/32E 2 m

3、m Inches mm Inches 0.13 .005 4.24 .17 0.25 .01 5.84 .23 0.51 .02 7.72 .30 1.57 .06 7.92 .31 2.00 .08 9.55 .38 2.50 .098 12.20 .48 2.54 .100 15.70 .62 FIGURE 1. Protective cover, plug, all classes - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from I

4、HS-,-,-MIL-DTL-38999/32E 3 Dimensions Shell size A THD-2A B dia max C dia + .00 - .15 D dia max E dia min F G + 13.0 - 7.0 9 .6250-0.1P-0.3L-TS 23.0 12.50 24.0 13.0 24.00 14.50 127.00 11 .7500-0.1P-0.3L-TS 26.0 15.75 27.0 18.0 20.50 18.00 127.00 13 .8750-0.1P-0.3L-TS 31.0 19.53 30.0 20.0 27.00 20.00

5、 127.00 15 1.0000-0.1P-0.3L-TS 33.0 22.71 31.0 23.0 22.50 18.00 127.00 17 1.1875-0.1P-0.3L-TS 37.0 25.88 37.0 26.0 30.50 23.50 127.00 19 1.2500-0.1P-0.3L-TS 40.0 28.55 40.0 29.0 31.50 25.00 127.00 21 1.3750-0.1P-0.3L-TS 44.0 31.72 44.0 32.0 33.00 26.50 127.00 23 1.5000-0.1P-0.3L-TS 46.0 34.90 46.0 3

6、4.0 34.00 27.50 127.00 25 1.6250-0.1P-0.3L-TS 50.0 38.07 49.0 39.0 38.00 30.00 127.00 NOTES: 1. Dimensions are in millimeters, except “A threads” which are in inches. 2. Method of attachment to cover and or ring is optional. FIGURE 1. Protective cover, plug, all classes - Continued. REQUIREMENTS: Di

7、mensions and configurations: See figure 1. Materials: Cover - Classes C, F, G, R, W, and X: Impact extruded or machined aluminum alloy. Classes P, T and Z: Impact extruded or machined aluminum alloy. Classes H, K, N, S and Y: Corrosion resistant steel. Classes J and M: High performance resin in acco

8、rdance with MIL-DTL-38999. Class F: Impact extruded or machined aluminum alloy. (Cover base material only. For finishes or surface treatments, see MIL-DTL-38999.) Gasket - Silicone elastomer. Ring - Corrosion resistant steel, passivated, 1.020 mm (0.04 inches) maximum thickness. Rope - Insulated sta

9、inless steel, passivated. Insulation shall withstand 200C environment. Fastener - Stainless steel, passivated. Option: Aluminum integral to cover. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/32E 4 Mating connectors: See MIL-DTL-3899

10、9, series III. Gasket shall be bonded to cover, or mechanically retained. Rope shall rotate freely on fastener. Fastener tensile strength: The protective cover and rope assembly shall withstand a dead weight tensile load of 25 pounds applied to both axial and longitudinal directions. The load shall

11、be applied at the end of the rope assembly and held for 5 minutes. There shall be no separation of the rope assembly from the protective cover or damage to the rope assembly. Both axial and longitudinal directions shall be 25 pounds. The load shall be applied to the end of the rope. Air Leakage: Tes

12、ting shall be in accordance with EIA-364-02, except the minimum period of measurement shall be 10 seconds. The air leakage rate shall be no greater than 1 atmospheric cubic inch per hour (4.55 X 10-3 cm3/s). Protective covers shall be mated to connectors having either contacts or inserts removed so

13、that a pressure of 10 lbft/in2 (.703 Kg/cm2 ) can be applied against the insides of the protective covers or stowage receptacles. Qualification (all classes). Qualification shall be in accordance with MIL-DTL-38999 except only the following sequence of tests shall be required: Examination of product

14、 Coupling torque Humidity Salt spray (corrosion) Fastener tensile strength (see requirement) Air Leakage Qualification (classes J and M only): Qualification shall be in accordance with MIL-DTL-38999, except that in addition to the test sequence specified for all classes above, the following tests sh

15、all be required: Temperature cycling Hydrolytic stability Group A sampling inspection. Sample sizes for group A inspection shall be as specified in table I. TABLE I. Group A sampling plan. Lot size Sampling size 1 to 13 100 percent 14 to 150 13 units 151 to 280 20 units 281 to 500 29 units 501 to 1,

16、200 34 units 1,201 to 3,200 42 units 3,201 and up 54 units Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/32E 5 Part or Identifying Number (PIN) example: Change effectivity. Unless otherwise specified by the preparing activity and/or t

17、he qualifying activity, all changes from the previous revision of this specification sheet shall become effective within 90 days of the date of publication of the latest revision. If unable to implement changes within the 90 day time period, the manufacturer or value added distributor shall notify t

18、he qualifying activity. The qualifying activity shall determine if an extension may be granted. Disposition of stock. Unless otherwise specified by the qualifying activity and coordinated with the preparing activity, qualified manufacturers and their selling agents or distributors may continue to sh

19、ip protective covers which were manufactured in accordance with the previous revision of this specification sheet for a period of 18 months from the date of the latest revision, provided that form, fit and function are not affected. Changes from previous issue. The margins of this specification are

20、marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document

21、based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. In addition to MIL-DTL-38999, this document references the following: EIA-364-02 CONCLUDING MATERIAL Custodians: Preparing activity: Army - CR DLA - CC Navy - AS Air

22、Force - 85 (Project 5935-2012-017) DLA - CC Review activities: Army - MI Navy - EC, MC, OS Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the

23、 information above using the ASSIST Online database at https:/assist.dla.mil. D38999/32 W 15 R Specification sheet number Class (see requirements) Shell size Style R - Rope N - With rope and ring Class F is not for Navy use and is inactive for use in Air Force new design. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN EN ISO 12572-2017 Hygrothermal performance of building materials and products - Determination of water vapour transmission properties - Cup method (ISO 12572 2016) German versi.pdf DIN EN ISO 12572-2017 Hygrothermal performance of building materials and products - Determination of water vapour transmission properties - Cup method (ISO 12572 2016) German versi.pdf
  • DIN EN ISO 12617-2017 Road vehicles - Liquefied natural gas (LNG) refuelling connector - 3 1 MPa connector (ISO 12617 2015 Corrected version 2016-01-15) German version EN ISO 12617.pdf DIN EN ISO 12617-2017 Road vehicles - Liquefied natural gas (LNG) refuelling connector - 3 1 MPa connector (ISO 12617 2015 Corrected version 2016-01-15) German version EN ISO 12617.pdf
  • DIN EN ISO 12625-1-2011 Tissue paper and tissue products - Part 1 General guidance on terms (ISO 12625-1 2011) Trilingual version EN ISO 12625-1 2011《薄纸和生活用纸产品 第1部分 关于术语的通用指引(ISO 1.pdf DIN EN ISO 12625-1-2011 Tissue paper and tissue products - Part 1 General guidance on terms (ISO 12625-1 2011) Trilingual version EN ISO 12625-1 2011《薄纸和生活用纸产品 第1部分 关于术语的通用指引(ISO 1.pdf
  • DIN EN ISO 12625-11-2013 Tissue paper and tissue products - Part 11 Determination of wet ball burst strength (ISO 12625-11 2012) German version EN ISO 12625-11 2012《薄纸和薄纸制品 第11部分 湿.pdf DIN EN ISO 12625-11-2013 Tissue paper and tissue products - Part 11 Determination of wet ball burst strength (ISO 12625-11 2012) German version EN ISO 12625-11 2012《薄纸和薄纸制品 第11部分 湿.pdf
  • DIN EN ISO 12625-12-2010 Tissue paper and tissue products - Part 12 Determination of tensile strength of perforated lines - Calculation of perforation efficiency (ISO 12625-12 2010.pdf DIN EN ISO 12625-12-2010 Tissue paper and tissue products - Part 12 Determination of tensile strength of perforated lines - Calculation of perforation efficiency (ISO 12625-12 2010.pdf
  • DIN EN ISO 12625-15-2015 Tissue paper and tissue products - Part 15 Determination of optical properties - Measurement of brightness and colour with C 2 (indoor daylight) illuminant.pdf DIN EN ISO 12625-15-2015 Tissue paper and tissue products - Part 15 Determination of optical properties - Measurement of brightness and colour with C 2 (indoor daylight) illuminant.pdf
  • DIN EN ISO 12625-16-2015 Tissue paper and tissue products - Part 16 Determination of optical properties - Opacity (paper backing) - Diffuse reflectance method (ISO 12625-16 2015) G.pdf DIN EN ISO 12625-16-2015 Tissue paper and tissue products - Part 16 Determination of optical properties - Opacity (paper backing) - Diffuse reflectance method (ISO 12625-16 2015) G.pdf
  • DIN EN ISO 12625-3-2014 Tissue paper and tissue products - Part 3 Determination of thickness bulking thickness apparent bulk density and bulk (ISO 12625-3 2014) German version EN I.pdf DIN EN ISO 12625-3-2014 Tissue paper and tissue products - Part 3 Determination of thickness bulking thickness apparent bulk density and bulk (ISO 12625-3 2014) German version EN I.pdf
  • DIN EN ISO 12625-4-2017 Tissue paper and tissue products - Part 4 Determination of tensile strength stretch at maximum force and tensile energy absorption (ISO 12625-4 2016) German.pdf DIN EN ISO 12625-4-2017 Tissue paper and tissue products - Part 4 Determination of tensile strength stretch at maximum force and tensile energy absorption (ISO 12625-4 2016) German.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1