1、 MIL-DTL-43492D 19 December, 2000 SUPERSEDING MIL-T-43492C 20 August 1987 DETAILED SPECIFICATION TENT SECTIONS, FRAME TYPE, EXPANDABLE This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers tent sections for

2、an expandable, frame-supported tent of wind-resistant cotton sateen (see 6.1). Minimum dimensions of the expandable tent are as follows: Length 16 feet; width 16 feet; ridge height 8 feet, 6 inches; eave height 6 feet. Also included are a cover for the 16 foot by 16 foot tent, and arch and purlin ca

3、rrying covers for the tent frame sections. 1.2 Classification. (see 6.2) Type I - End section Type II - Intermediate section 2. APPLICABLE DOCUMENTS *2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cit

4、ed in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this speci

5、fication, whether or not they are listed. Beneficial comments (recommendations, additions, deletions, clarifications) and any pertinent data which may be of use in improving this document should be addressed to: Defense Supply Center Philadelphia, Clothing and Textiles Directorate, Attn: DSCP-CNR, 7

6、00 Robbins Ave., Philadelphia, PA 19111-5096 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 8340 INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI

7、L-DTL-43492D 2 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the

8、Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS FEDERAL L-S-125 - Screening, Insect, Nonmetallic V-F-106 - Fasteners, Slide, Interlocking V-T-285 - Thread, Polyester TT-P-595 - Preservative Coating, Canv

9、as DDD-L-20 - Label: For Clothing, Equipage and Tentage (General Use) A-A-3174 - Plastic Sheet and Strip, Thin Gauge, Polyolefin A-A-50057 - Rope, Fibrous, Tent Lay A-A-55126 - Fastener tapes, Hook and Loop, Synthetic MILITARY MIL-C-496 - Clips, End Strap MIL-W-530 - Webbing, Textile, Cotton, Genera

10、l Purpose MIL-H-639 - Hooks (for Belts, Straps, and Equipage Items) MIL-L-1709 - Lines, Tent MIL-S-1734 - Slips, Tent Line MIL-R-2327 - Rings, Connecting, Round MIL-W-4088 - Webbing, Textile, Woven, Nylon MIL-F-10884 - Fasteners, Snap MIL-L-11075 - Loops, Strap Fastener MIL-PRF-20696 - Cloth, Coated

11、, Polyester or Nylon, Waterproof MIL-R-30500 - Rope, Polyester MIL-PRF-44103 - Cloth, Duck, Polyester, MIL-DTL-43002 - Shield, Stovepipe, Tent, Nonmetallic MIL-C-43256 - Cord, Polyester, Solid Braid MIL-T-43566 - Tape, Textile, Cotton or Polyester, General Purpose, Natural or in Colors MIL-W-44049 -

12、 Webbing, Textile and Tape, Textile, Polypropylene, General Purpose, Natural or in Colors STANDARDS MILITARY MS 70101 - Adapter, Reversible, Quick Fit, 500 lb.; 1 Inch (Unless otherwise indicated. copies of federal and military specifications, standards, and handbooks are available from the Document

13、 Automation and Production Service (DAPS), Bldg. 4D (DPM-DODSSP), 700 Robbins Avenue, Philadelphia, PA 19111-5094.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-43492D 3 2.2.2 Other Government documents, drawings, and publications. The fol

14、lowing other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DEPARTMENT OF THE ARMY FIELD MANUAL FM 10-16 General Repair of Tents, Canvas and Webbing (Copies of t

15、he manual are available from the U. S. Army Biological and Chemical Command, ATTN: SSCNC-EMSS, Natick, MA 01760-5017.) DRAWINGS U.S. ARMY BIOLOGICAL CHEMICAL COMMAND 5-4-783 - Tent, General Purpose, Small; Cover 5-4-961 - Tent Sections, Frame Type, Expandable; Assembly 5-4-962 Intermediate Section 5

16、-4-963 End Section 5-4-964 End Section Sections 5-4-965 Window Details 5-4-966 Window Sections 5-4-967 Purlin and Heater Duct Details and Sections 5-4-968 Intermediate Vent Assembly 5-4-969 Intermediate Vent Sections 5-4-970 Stovepipe Opening Details and Sections 5-4-971 Becket Loop and Guy Line Lug

17、 Details, Sections and Enlarged Views 5-4-972 End Vent Assembly 5-4-973 End Vent Sections 5-4-974 - Door Detail and Sections 5-4-1043 - Carrying Cover, Arch 5-4-1044 - Carrying Cover, Purlin 5-4-1760 - Erection Instructions (Copies of drawings are available from the U. S. Army Biological Chemical Co

18、mmand, ATTN: AMSSB-REO-S(N), NATICK, MA 01760-5017.) 2.3 Non-Government publications. The following document(s) form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the DODISS cited

19、 in the solicitation. Unless otherwise specified, the issues of documents not listed in the DODISS are the issues of the documents cited in the solicitation (see 6.2). AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM-D-2016 - Standard Test Methods for Moisture Content of Wood ASTM-D-6193 - Sta

20、ndard Practice for Stitches and Seams (Applications for copies of referenced documents should be addressed to the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19426-2959.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license

21、 from IHS-,-,-MIL-DTL-43492D 4 AEROSPACE INDUSTRIES ASSOCIATION OF AMERICA NASM16491 - Grommet, Metallic, General Specification For (Applications for copies of referenced documents should be addressed to the Aerospace Industries Association of America, Inc., 1250 Eye Street, N. W. Washington, DC 200

22、05-3924.) *2.4 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification takes precedence. Nothing in this specification, however, supersedes applicable laws and regulations unless a specific exemption has b

23、een obtained. 3. REQUIREMENTS *3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection (see 4.2 and 6.2). 3.2 Materials and components. 3.2.1 Cloth. 3.2.1.1 Cloth, Duck Cloth for the tent sections shall conform to MIL-PRF-44103, Class 1, Grade A , 1, 1-1/

24、2 and 2 inch widths of MIL-T-43566. For covers only, as an alternate, the tape shall be polypropylene conforming to type I, class 4 of MIL-W-44049. The color of the tapes shall be camouflage green 483. 3.2.3 Webbing. 3.2.3.1 Webbing, cotton. Cotton webbing shall conform to type IIb, class 4, 1 inch

25、width of MIL-W-530. The color shall be camouflage green 483. 3.2.3.2 Webbing, nylon. Nylon webbing shall conform to type VIII, class 1 or class 2 of MIL-W-4088. The color shall be camouflage green 483. 3.2.4 Thread, polyester. Thread shall conform to type I, class 1, subclass B of V-T-285. The dyed

26、thread shall show colorfastness to weathering equal to or better than the standard sample (see 6.5). The color shall be camouflage green 483. When no standard shade sample is available, the dyed thread shall show good colorfastness to weathering. Thread size shall be as follows: Provided by IHSNot f

27、or ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-43492D 5 a. For all stitching except zig-zag stitching and stitching indicated by “Z” on drawings size FF for needle and bobbin. b. For zig-zag stitching, size E for needle and bobbin. c. For stitching indicated by

28、 “Z” on drawing size FF for needle and size F for looper. Alternate Thread size “E” for needle/bobbin and “F” for needle may be used for bartacking, box stitch formations and “W” stitch formations. *3.2.5 Fastener tape. Hook and loop fastener tape shall conform to 1 or 2 inch widths, type II hook, c

29、lass 3 of A-A-55126. The color shall be camouflage green 483. 3.2.6 Lines, tent. Tent lines shall conform to types I, XXI and XXXV of MIL-L-1709 except that the type XXXV lines shall be finished in accordance with figure 3 of MIL-L-1709. Tent lines in types specified may be fabricated from sisal, po

30、lyester or duel fiber polyethylene/polyester as alternates. Polyester rope shall be in accordance with MIL-R-30500. 3.2.7 Stiffener, rope. Rope stiffeners for the window flaps and drip caps shall conform to type I or II, class 2, 1 inch circumference of MIL-R-1670. 3.2.8 Cord, polyester. Cord for th

31、e becket lines, vent lines, window flap lines and toggle loops shall be 1/8 inch diameter, conforming to MIL-C-43256. The color shall be camouflage green 483. 3.2.9 Screening, Non-Metallic The screening shall be Type III, class 1 or 2, size 18 X 18, color green of L-S-125, or Type II, class 2, size

32、18 X 18 color green of L-S-125. *3.2.10 Film, plastic. Plastic film shall conform to the requirements for 0.0060 inch thick film, type I, class 1, grade A, B or C, finish 1 of A-A-3174 except that the film thickness shall be 0.020 + 0.004 inch. The requirements for slip, ink adhesion, water vapor pe

33、rmeability, impact resistance and heat seal strength shall not apply and the elongation at break, minimum percent (TD) shall be 290. *3.2.11 Shield, pipe. Stovepipe shields shall conform to MIL-DTL-43002. 3.2.12 Fasteners, snap. Snap fasteners shall conform to style 2, finish 2, button 24 line size,

34、 size 1 of MIL-F-10884. 3.2.13 Fasteners, slide, interlocking. The slide fastener shall conform to size H of V-F-106. The slide fastener chain shall be fabricated of brass or polyester coil. The slider for the brass chain shall be brass and the slider for the polyester coil shall be die case zinc al

35、loy. The length of the slide fastener chain shall be such that after the slide fastener is sewed on, the tape shall not be puckered and the slider shall operate freely. The color of the slide fastener tape shall be camouflage green 483. The tape shall be water repellent and mildew resistant treated.

36、 The tape shall show good fastness to weathering. Alternatively, the slide fastener chain shall be polyester continuous monofilament in a ladder or coil type configuration. The color of the chain, slider, pull and stops shall approximate the shade of the tape. Provided by IHSNot for ResaleNo reprodu

37、ction or networking permitted without license from IHS-,-,-MIL-DTL-43492D 6 As an alternate to using preassembled slide fasteners, a continuous chain application may be utilized as part of the manufacturing method. The method requires that the entire chain tape and tape extensions be securely stitch

38、ed with the required seam without any puckering or waviness. The slider shall be indented into position to provide for a smooth running chain disengagement with the slider mouth squarely against the bottom staple stop and for a smooth running chain engagement with the slider throat evenly against th

39、e top stops and with no excess chain element showing. If continuous monofilament polyester chain is used, sewn top stops without gapping are allowed. 3.2.13.1 Flap, window. Window flap fasteners shall be type I, style 18, single wire stirrup pull. 3.2.13.2 Fasteners, door. Door fasteners shall be ty

40、pe III, style 6 of V-F-106, double wire stirrup pull. 3.2.14 Grommet, metallic. Grommets shall conform to type III, class 3, size Nos. 0, 1, 3, 4 and 5 of MIL-G-16491. 3.2.15 Hooks, “S”. “S” hooks shall conform to type XII, class 2, size G of MIL-H-639. *3.2.16 Slips, tent line. Tent line slips shal

41、l conform to type II of MIL-S-1734. As an alternate, “S” hooks conforming to Chicago Hardware and Fixture Style No. S-2-A (Zinc Plated, .148 wire size, 1 inches length) or equal may be substituted. 3.2.17 Loops, strap fastener. Strap loops shall conform to type III style B of MIL-L-11075. 3.2.18 Cli

42、ps, end. End clips shall conform to type I, class I or 2, 1 inch of MIL-C-496. 3.2.19 Adapter. Adapters for the carrying covers shall conform to the material, design and dimensions specified on MS 70101. 3.2.20 Rings, connecting. Connecting rings shall conform to class 2 or 5, size 4 of MIL-R-2327.

43、3.2.21 Toggles, wood. Wood toggles shall be of the design and dimensions shown on Drawing 5-4-971. The toggles shall be fabricated from straight-grained, sound and smooth lumber and shall contain not more than 15% moisture when tested as specified in 4.4.1.1. The toggles shall be free from knots, sh

44、akes, checks, splits, splintery surfaces, or case hardening. Any of the following woods may be used: Ash Hickory Elm, rock Pecan Beech Maple, hard Birch, yellow Oak, red or white 3.3 Construction. Construction shall conform to the drawings listed in section 2 and as specified herein. 3.3.1 Stitching

45、, machine. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-43492D 7 *3.3.1.1 Types. All stitch types, except bartacking, shall conform to ASTM-D-6193 as follows: a. For all stitching except zig-zag stitching and stitching indicated by “Z” on

46、drawings and for attachment of slide fasteners type 301, 5 to 7 stitches per inch. b. For zig-zag stitching - type 304, 10 to 14 stitches per inch. c. For stitching indicated by “Z” on drawings and for attachment of slide fasteners type 401, 5 to 7 stitches per inch. Chain portion of stitching shall

47、 not appear on outside of tent or covers. d. For bartacking 5/8 + 1/16 inch long, 1/8 inch minimum bight and containing 28 stitches. 3.3.1.2 Thread breaks. Thread breaks in stitching shall be overstitched not less than 1 inch at each break on stitch type 301, not less than inch at each break on stit

48、ch type 304 and not less than 1 inches at each break on stitch type 401. Thread breaks in type 401 stitching may be overstitched with stitch type 301. Bartacks shall be free of thread breaks. 3.3.1.3 Stitching ends. The ends of 301 stitching shall be overstitched not less than 1 inch except where en

49、ds are turned under in a hem or held down by other stitching. Where 301 stitching is performed automatically on stitch patterns such as box, box with cross-stitch, “W” stitching or straight line tacking, not less than three tying, overlapping , or back stitches shall be used to secure the ends of stitching. The ends of type 304 stitching shall be firmly secured by bac