DLA MIL-DTL-83528 10 D-2013 GASKETING MATERIAL CONDUCTIVE ELASTOMER ELECTRICAL EMI RFI CHANNEL STRIP.pdf

上传人:confusegate185 文档编号:691151 上传时间:2018-12-30 格式:PDF 页数:3 大小:27.08KB
下载 相关 举报
DLA MIL-DTL-83528 10 D-2013 GASKETING MATERIAL CONDUCTIVE ELASTOMER ELECTRICAL EMI RFI CHANNEL STRIP.pdf_第1页
第1页 / 共3页
DLA MIL-DTL-83528 10 D-2013 GASKETING MATERIAL CONDUCTIVE ELASTOMER ELECTRICAL EMI RFI CHANNEL STRIP.pdf_第2页
第2页 / 共3页
DLA MIL-DTL-83528 10 D-2013 GASKETING MATERIAL CONDUCTIVE ELASTOMER ELECTRICAL EMI RFI CHANNEL STRIP.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 MIL-DTL-83528/10D 12 August 2013 SUPERSEDING MIL-DTL-83528/10C 15 November 2001 DETAIL SPECIFICATION SHEET GASKETING MATERIAL, CONDUCTIVE, ELASTOMER, ELECTRICAL, EMI/RFI, CHANNEL STRIP This specification is approved for use by all Departments and Agencies of the Department of Defense. The requireme

2、nts for acquiring the relay described herein shall consist of this specification sheet and the latest issue of MIL-DTL-83528. NOTES: 1. Dimensions are in inches; metric equivalents are given in parenthesis and are for general information only. 2. Length shall be as specified on the purchase order. F

3、IGURE 1. EMI/RFI gasket, elastomer, and channel strip. AMSC N/A FSC 5999 INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83528/10D 2 REQUIREMENTS: Design and interface: See figure 1 and table I. Material: Type A, B, C, D, E, F, J,

4、K, L, or M. Part or Identifying Number (PIN): See table I. Supersession information: See table II. TABLE I. Dimensions. PIN 1/ M83528/010X Nominal dimensions 2/ 3/ Cross section area (cm2) 4/ A B C D 001 0.100 (2.54) 0.100 (2.54) 0.034 (0.86) 0.033 (0.84) 0.050 002 0.126 (3.20) 0.110 (2.79) 0.025 (0

5、64) 0.050 (1.27) 0.079 003 0.126 (3.20) 0.225 (5.72) 0.020 (0.51) 0.075 (1.91) 0.164 004 0.156 (3.96) 0.156 (3.96) 0.062 (1.57) 0.047 (1.19) 0.113 005 0.175 (4.45) 0.156 (3.96) 0.047 (1.19) 0.075 (1.91) 0.152 006 0.327 (8.31) 0.235 (5.97) 0.062 (1.57) 0.115 (2.92) 0.448 1/ “X” in the PIN shall be r

6、eplaced by the applicable material type. Complete PIN example: M38528/0010A001. 2/ Dimensions are in inches; metric equivalents are given in parenthesis and are for general information only. 3/ Tolerance shall be as follows: Dimensions Tolerance Under .101 (2.57) .101 to .200 (2.57 to 5.08) .201 to

7、300 (5.10 to 7.62) .301 to .500 (7.62 to 12.70) .005 (0.13) .008 (0.20) .010 (0.25) .015 (0.38) 4/ For calculation of volume resistivity (for reference only). TABLE II. Supersession information. PIN 1/ M83528/010X Superseded DESC Drawing PIN 85109X 1/ 001 001002 002003 003 004 004005 005006 006 1/

8、X” in the PIN indicates the applicable material type. Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for

9、 any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. This document references MIL-DTL-83528. Prov

10、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83528/10D 3 Custodians: Preparing activity: Army CR DLA CC Navy EC Air Force 85 (Project 5999-2013-006) DLA CC Review activities: Air Force 19, 99 NSA NS NOTE: The activities listed above were inter

11、ested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 50559-2013 Electric room heating underfloor heating characteristics of performance - Definitions method of testing sizing and formula symbols German version EN 50559 2013《室内.pdf DIN EN 50559-2013 Electric room heating underfloor heating characteristics of performance - Definitions method of testing sizing and formula symbols German version EN 50559 2013《室内.pdf
  • DIN EN 50564-2011 Electrical and electronic household and office equipment - Measurement of low power consumption (IEC 62301 2011 modified) German version EN 50564 2011《电器及电子家用和办公设.pdf DIN EN 50564-2011 Electrical and electronic household and office equipment - Measurement of low power consumption (IEC 62301 2011 modified) German version EN 50564 2011《电器及电子家用和办公设.pdf
  • DIN EN 50580-2012 Safety of hand-held electric motor operated tools - Particular requirements for spray guns German version EN 50580 2012《手持电动工具的安全 喷枪的特殊要求 德文版本EN 50580-2012》.pdf DIN EN 50580-2012 Safety of hand-held electric motor operated tools - Particular requirements for spray guns German version EN 50580 2012《手持电动工具的安全 喷枪的特殊要求 德文版本EN 50580-2012》.pdf
  • DIN EN 50581-2013 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances German version EN 50581 2.pdf DIN EN 50581-2013 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances German version EN 50581 2.pdf
  • DIN EN 50582-2017 Procedure to assess the circuit integrity of optical fibres in a cable under resistance to fire testing German version EN 50582 2016《评定防火试验下光缆内光纤线路完整性的程序 德文版本EN 5.pdf DIN EN 50582-2017 Procedure to assess the circuit integrity of optical fibres in a cable under resistance to fire testing German version EN 50582 2016《评定防火试验下光缆内光纤线路完整性的程序 德文版本EN 5.pdf
  • DIN EN 50588-1-2016 Medium power transformers 50 Hz with highest voltage for equipment not exceeding 36 kV - Part 1 General requirements German version EN 50588-1 2015《设备最高电压不超过36 .pdf DIN EN 50588-1-2016 Medium power transformers 50 Hz with highest voltage for equipment not exceeding 36 kV - Part 1 General requirements German version EN 50588-1 2015《设备最高电压不超过36 .pdf
  • DIN EN 50600-1-2013 Information technology - Data centre facilities and infrastructures - Part 1 General concepts German version EN 50600-1 2012《信息技术 数据中心设施和基础设施 第1部分 通用概念 德文版本EN 5.pdf DIN EN 50600-1-2013 Information technology - Data centre facilities and infrastructures - Part 1 General concepts German version EN 50600-1 2012《信息技术 数据中心设施和基础设施 第1部分 通用概念 德文版本EN 5.pdf
  • DIN EN 50629-2016 Energy performance of large power transformers (Um  36 kV or Sr = 40 MVA) German version EN 50629 2015《大型电力变压器的能量性能 (Um 36 kV或者Sr≥40 MVA) 德文版本EN 50629-2015》.pdf DIN EN 50629-2016 Energy performance of large power transformers (Um 36 kV or Sr = 40 MVA) German version EN 50629 2015《大型电力变压器的能量性能 (Um 36 kV或者Sr≥40 MVA) 德文版本EN 50629-2015》.pdf
  • DIN EN 50667-2017 Information technology - Automated infrastructure management (AIM) systems - Requirements data exchange and applications German version EN 50667 2016《信息技术 自动化基础设施.pdf DIN EN 50667-2017 Information technology - Automated infrastructure management (AIM) systems - Requirements data exchange and applications German version EN 50667 2016《信息技术 自动化基础设施.pdf