1、 AMSC N/A FSC 5920 INCH-POUND MIL-PRF-15160/3H 15 October 2008 SUPERSEDING MIL-PRF-15160/3G 7 July 2006 PERFORMANCE SPECIFICATION SHEET FUSES, INSTRUMENT, POWER, AND TELEPHONE (NONINDICATING), STYLE F03 This specification is approved for use by all Departments and Agencies of the Department of Defen
2、se. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-15160. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. FIGURE 1. Style F03, fuse. Inches mm 0.004 0.10 0.010 0.25 0.031 0.79 0.230 5
3、.84 0.250 6.35 1.250 31.75 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/3H 2 REQUIREMENTS: Interface and physical dimensions: See figure 1. Terminals: Ferrule type. Material: Brass, copper, or copper alloy. Finish: Nickel, or silver
4、plated when specified. Strength: Method 211 of MIL-STD-202, test condition E, 2 inch-pound torque between ferrules and fuse body. Body: Plastic or ceramic tube. Electrical: Current rating: See table I. Voltage rating: See table I. Characteristic: See table I. Overload interrupt: See table I (at all
5、temperatures between minus 55C and plus 85C). Short circuit interrupt: See table I. Shock: F03A 1/4A through 1/2A MIL-STD-202, method 213, test condition I F03A 1A through 30A MIL-STD-202, method 207, (HI shock) F03B 1/100A through 8/10A MIL-STD-202, method 213, test condition I F03B 1A through 30A
6、MIL-STD-202, method 207, (HI shock) Vibration: F03A 1/4A through 30A MIL-STD-202, method 204, test condition A (except 5g peak) F03B 1/100A through 8/10A MIL-STD-202, method 201 F03B 1A through 30A MIL-STD-202, method 204, test condition A (except 5g peak) Type designation: Type designation shall be
7、 as specified in table I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE I Type designations and electrical rating. See footnotes at end of table. Type designation Overload interrupt time 2/ Style Characteristic Maximum Current 135% of rating
8、Max. 1 hour AC short circuit interrupt. voltage rating 3/ (amperes) 200% of rating (seconds) 300% of rating (seconds) 32 volts 125 volts 250 volts F03 1/ A 250V 1/4A 0.02 2.0 0.01 0.20 10,000A 10,000A 35A F03 1/ A 250V 1/2A 0.03 3.0 0.01 0.30 10,000A 10,000A 35A F03 A 250V 1A 0.05 3.0 0.015 0.50 10,
9、000A 10,000A 35A F03 1/ A 250V 1 1/4A 0.05 3.0 0.02 0.50 10,000A 10,000A 35A F03 1/ A 250V 1 1/2A 0.05 3.0 0.02 0.50 10,000A 10,000A 35A F03 1/ A 250V 2A 0.08 3.0 0.04 0.50 10,000A 10,000A 35A F03 A 250V 3A 0.08 3.0 0.04 0.70 10,000A 10,000A 35A F03 1/ A 250V 4A 0.10 5.0 0.05 1.00 10,000A 10,000A 35
10、A F03 A 250V 5A 0.20 60.0 0.05 6.00 10,000A 10,000A 100A F03 1/ A 250V 6A 0.20 60.0 0.05 6.00 10,000A 10,000A 100A F03 A 250V 8A 0.30 60.0 0.05 6.00 10,000A 10,000A 100A F03 A 250V 10A 0.30 60.0 0.05 6.00 10,000A 10,000A 100A F03 A 250V 12A 0.30 60.0 0.05 6.00 10,000A 10,000A 200A F03 A 250V 15A 0.5
11、 60.0 0.05 6.00 10,000A 10,000A 200A F03 A 125V 20A 0.5 60.0 0.05 6.00 10,000A 10,000A Not rated F03 1/ A 125V 25A 0.5 60.0 0.05 6.00 10,000A 10,000A Not rated F03 A 125V 30A 0.5 60.0 0.05 6.00 10,000A 10,000A Not rated F03 B 250V 1/100A 4.0 250.0 2.0 40.0 10,000A 10,000A 35A F03 B 250V 1/32A 4.0 80
12、.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 1/16A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 1/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 1/8A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 15/100A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 3/16A 4.0 80.0 2.0 25.0 10,000A 1
13、0,000A 35A F03 B 250V 1/4A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 3/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 3/8A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A MIL-PRF-15160/3H 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE
14、I Type designations and electrical rating - Continued. 1/ INACTIVE FOR NEW DESIGN AFTER 30 JANUARY 1970. 2/ The overload interrupt time ranges, as shown, cover the temperature range from minus 55C to plus 85C. For characteristic B, the overload interrupt time at room ambient temperature shall be not
15、 less than 12 seconds at 200 percent rating. 3/ For silver plated terminals the designator “S” is added after the current rating. Type designation Overload interrupt time 2/ Style Characteristic Maximum Current 135% of rating Max. 1 hour AC short circuit interrupt. voltage rating 3/ (amperes) 200% o
16、f rating (seconds) 300% of rating (seconds) 32 volts 125 volts 250 volts F03 B 250V 1/2A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 6/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 3/4A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 8/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03
17、 B 250V 1A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 1 1/4A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 1 1/2A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 1 6/10A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 2A 4.0 80.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 2 1/2A
18、10.0 250.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 2 8/10A 10.0 250.0 2.0 25.0 10,000A 10,000A 35A F03 B 250V 3A 10.0 250.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 250V 3 2/10A 10.0 250.0 2.0 25.0 10,000A 10,000A 35A F03 1/ B 125V 4A 10.0 250.0 2.0 25.0 10,000A 10,000A Not rated F03 B 125V 5A 10.0
19、250.0 0.05 10.0 10,000A 10,000A Not rated F03 1/ B 125V 6 1/4A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 1/ B 125V 7A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 8A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 10A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03
20、 B 125V 12A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 15A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 20A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 1/ B 125V 25A 10.0 250.0 0.05 10.0 10,000A 10,000A Not rated F03 B 125V 30A 10.0 250.0 0.05 10.0 10,000A 10,000A
21、Not rated MIL-PRF-15160/3H 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/3H 5 VERIFICATION: Qualification inspection is not applicable for the 1/4A, 1/2A characteristic A and the 1/100A, 1/32A, and 1/16A characteristic B fuses (see
22、table l) of this specification sheet and shall be replaced by acceptance testing consisting of Group A and Group B inspections per MIL-PRF-15160, prior to delivery. INSPECTION ROUTINE: Overload tests (group II): Fuses for the overload interrupt test shall be selected and tested as specified in table
23、 II for qualification test. TABLE II. Overload tests. Examination of test Number of sample fuses Group II Terminal strength Overload interrupt 1/ 135% at room ambient 200% at 55C 200% at +85C 300% at 55C 300% at +85C 20 12 4 4 4 4 4 1/ For characteristic B fuses, only, four additional fuses shall be
24、 tested at 200 percent of rating at room ambient temperature. Low voltage overload interrupt (group V for qualification; group III for group C inspection): Four sample characteristic B fuses of each current rating shown in table III shall be subjected to 135 percent current at the voltage specified
25、in the table. The fuses shall interrupt the circuit within 1 hour. The test shall be conducted at room ambient. TABLE III. Low voltage overload interrupt. (Characteristic B fuses only). Ampere rating Test voltage 1/100A 36V 1/4A 15V 1/2A 10V 6/10A 8V 8/10A 6V 1A 5V Note - for low voltage application
26、s, see 6.1.5.1 for caution regarding low voltage applications. Short circuit test: The number of group III samples for qualification and qualification retention (group C) testing shall consist of 4 sample fuses of each of the types and of the current ratings as shown in table IV. Short circuit inter
27、rupt tests shall be conducted at the ac voltage indicated, and the fuses shall withstand a minimum short circuit current as shown in table IV. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/3H 6 TABLE IV. Short circuit tests. Fuse type
28、 Current rating Short circuit current AC test voltage F03A 4A 35A 250V F03A 10A 100A 250V F03A 15A 200A 250V F03A 30A 10,000A 125V F03B 3 2/10A 35A 250V F03B 30A 10,000A 125V Cross-reference: For applicable cross-reference see table V. The existing stocks of superseded items may be used. When exhaus
29、ted, the superseding parts shall be used. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE V. Cross reference. 1/ See notes at end of table. Superseding Superseded numbers for CAGE number 81349 96906 71400 71400 75915 75915 75915 98997 F03A250V1
30、/4A 1/ ABC1/4 MBO 1/4 394.250 314.250 3AB1/4 3AB1/4 F03A250V1/2A ABC1/2 MBO 1/2 394.500 314.500 3AB1/2 3AB1/2 F03A250V1A F03G1R00A 1/ MS90079-1 1/ ABC1 MBO 1 394001 314001 3AB1 3AB1 F03A250V1 1/4A ABC1 1/4 MBO1 1/4 3941.25 3141.25 3AB1 1/4 3AB1 1/4 F03A250V1 1/2A ABC1 1/2 MBO1 1/2 39401.5 31401.5 3A
31、B1 1/2 3AB1 1/2 F03A250V2A ABC2 MBO2 394002 314002 3AB2 3AB2 F03A250V3A F03G3R00A MS90079-2 ABC3 MBO3 394003 314003 3AB3 3AB3 F03A250V4A ABC4 MBO4 394004 314004 3AB4 3AB4 F03A250V5A F03G5R00A MS90079-3 ABC5 MBO5 394005 314005 3AB5 3AB5 F03A250V6A ABC6 MBO6 394006 314006 3AB6 3AB6 F03A250V8A F03G8R00
32、A MS90079-4 ABC8 MBO8 394008 314008 3AB8 3AB8 F03A250V10A F03G10R0A MS90079-5 ABC10 MBO10 394010 314010 3AB10 3AB10 F03A250V12A F03G12R0A MS90079-6 ABC12 MBO12 394012 314012 3AB12 3AB12 F03A250V15A F03G15R0A MS90079-7 ABC15 MBO15 394015 314015 3AB15 3AB15 F03A125V20A F03D20R0A MS90079-8 ABC20 MBO20
33、394020 314020 3AB20 3AB20 F03A125V25A ABC25 MBO25 394025 314025 3AB25 3AB25 F03A125V30A F03D30R0A MS90079-9 ABC30 MBO30 394030 314030 3AB30 3AB30 F03B250V1/100A F03GR010B MS90079-10 MDA1/100 MBF 1/100 390.010 323.010 3ABTL1/100 F03B250V1/32A F03GR031B MS90079-11 MDA1/32 MDF1/32 390.031 323.031 3ABTL
34、1/32 F03B250V1/16A F03GR062B MS90079-12 MDA1/16 MDF1/16 390.062 323.062 3ABTL1/16 F03B250V1/10 F03B250V1/8A F03GR125B MS90079-13 MDA1/8 MDF1/8 390.125 323.125 3ABTL1/8 F03B250V15/100A F03GR150B MS90079-14 MDA15/100 MDF15/100 390.150 323.150 3ABTL15/100 F03B250V3/16A F03GR187B MS90079-15 MDA3/16 MDF3
35、/16 390.187 323.187 3ABTL3/16 F03B250V1/4A F03GR250B MS90079-16 MDA1/4 MDF1/4 390.250 323.250 3ABTL1/4 F03B250V3/10A MDA3/10 MDF3/10 390.300 323.300 3ABTL3/10 F03B250V3/8A F03GR375B MS90079-17 MDA3/8 MDF3/8 390.375 323.375 3ABTL3/8 F03B250V1/2A F03GR500B MS90079-18 MDA1/2 MDF1/2 390.500 323.500 3ABT
36、L1/2 F03B250V6/10A MDA6/10 MDF6/10 390.600 323.600 3ABTL6/10 F03B250V3/4A F03GR750B MS90079-19 MDA3/4 MDF3/4 390.750 323.750 3ABTL3/4 F03B250V8/10A MDA8/10 MDF8/10 390.800 323.800 3ABTL8/10 MIL-PRF-15160/3H 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from I
37、HS-,-,-TABLE V. Cross reference - Continued. 1/ A letter “S” following the part number signifies silver plating. 2/ A second dash number (-1) signifies silver plating. MIL-PRF-15160/3H Superseding Superseded numbers for CAGE number 81349 96906 71400 71400 75915 75915 75915 98997 F03B250V1A F03G1R00B
38、 MS90079-20 MDA1 MDF1 390001 323001 3ABTL1 F03B250V1 1/4A MDA1 1/4 MDF1 1/4 390.250 3231.25 3ABTL1 1/4 F03B250V1 1/2A MDA1 1/2 MDF1 1/2 390.500 3231.5 3ABTL1 1/2 F03B250V1 6/10A MDA1 6/10 MDF1 6/10 390.600 32301.6 3ABTL1 6/10 F03B250V2A F03B125V2A MDA2 MDF2 390002 323002 3ABTL2 F03B250V2 1/2A F03B12
39、5V1/2A MDA2 1/2 MDF2 1/2 39002.5 32302.5 3ABTL2 1/2 F03B250V2 8/10A F03B125V28/10A MDA2 8/10 MDF2 8/10 39002.8 32302.8 3ABTL2 8/10 F03B250V3A 1/ F03GR00B 1/ MS90079-21 2/ MDA3 MDF3 390003 323003 3ABTL3 F03B125V3A F03B250V3 2/10A F03B125V32/10A MDA3 2/10 MDF3 2/10 39003.2 32303.2 3ABTL3 2/10 F03B125V
40、4A MDA4 MDF4 390004 323004 3ABTL4 F03B125V5A F03G5R00B MS90079-22 MDA5 MDF5 390005 323005 3ABTL5 F03D5R00B F03B32V5A F03B125V6 1/4A 1/ F03B32V6 1/4A 1/ MDA6 1/4 MDF6 1/4 3906.25 3236.25 3ABTL6 1/4 F03B125V7A F03B32V7A MDA7 MDF7 390007 323007 3ABTL7 F03B125V8A F03G8R00B MS90079-23 2/ MDA8 MDF8 390008
41、 323008 3ABTL8 F03B32V8A F03B125V10A F03G10R0B MS90079-24 MDA10 MDF10 390010 323010 3ABTL10 F03B32V10A F03B125V12A F03G12R0B MS90079-25 MDA12 MDF12 390012 323012 3ABTL12 F03B32V12A F03B125V15A F03G15R0B MS90079-26 MDA15 MDF15 390015 323015 3ABTL15 F03B32V15A F03B125V20A F03D20R0B MS90079-27 MDA20 MD
42、F20 390020 323020 3ABTL20 F03B32V20A F03B125V25A F03D25R0B MDA25 MDF25 390025 323025 3ABTL25 F03B32V25A F03B125V30A F03D30R0B MS90079-28 MDA30 MDF30 390030 323030 3ABTL30 F03B32V30A 8 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/3H 9
43、 Referenced documents. In addition to MIL-PRF-15160, this document references the following: MIL-STD-202 The margins of this specification sheet are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes
44、no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Custodians: Preparing activity: Army -
45、CR DLA - CC Navy - SH Air Force - 85 (Project 5920-2008-038) DLA - CC Review activities: Army - AR, AT, CR4, MI Navy - AS, CG, MC, OS Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-