DLA MIL-PRF-3098 93 C-2009 CRYSTAL UNIT QUARTZ CR117 U.pdf

上传人:livefirmly316 文档编号:692826 上传时间:2018-12-30 格式:PDF 页数:4 大小:40.24KB
下载 相关 举报
DLA MIL-PRF-3098 93 C-2009 CRYSTAL UNIT QUARTZ CR117 U.pdf_第1页
第1页 / 共4页
DLA MIL-PRF-3098 93 C-2009 CRYSTAL UNIT QUARTZ CR117 U.pdf_第2页
第2页 / 共4页
DLA MIL-PRF-3098 93 C-2009 CRYSTAL UNIT QUARTZ CR117 U.pdf_第3页
第3页 / 共4页
DLA MIL-PRF-3098 93 C-2009 CRYSTAL UNIT QUARTZ CR117 U.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC N/A FSC 5955 INCH-POUND MIL-PRF-3098/93C 7 August 2009 SUPERSEDING MIL-PRF-3098/93B 17 May 2004 PERFORMANCE SPECIFICATION SHEET CRYSTAL UNIT, QUARTZ, CR117/U This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the

2、product described herein shall consist of this specification sheet and MIL-PRF-3098. Pertinent characteristics: 30 MHz to 63 MHz; third mechanical overtone; noncontrolled; series resonance. FIGURE 1 Crystal unit - CR117/U. Provided by IHSNot for ResaleNo reproduction or networking permitted without

3、license from IHS-,-,-MIL-PRF-3098/93C 2 Ltr Inches mm Min Max Min Max A - .402 - 10.21 B .184 .200 4.67 5.08 C - .435 - 11.05 D .223 .248 5.66 6.30 E - .150 - 3.81 F - .530 - 13.46 G .038 .042 0.96 1.07 H - .183 - 4.65 J .165 .175 4.19 4.44 K .027 .032 0.69 0.89 L .015 .025 0.38 0.63 NOTES: 1. Dimen

4、sions are in inches. 2. Metric equivalents are given for general information only. 3. Marking to be in accordance with MIL-PRF-3098. FIGURE 1 Crystal unit - CR117/U - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-3098/93C 3 REQUI

5、REMENTS: Dimensions, marking, and configuration: See figure 1. Frequency range: 30 MHz to 63 MHz, inclusive. Frequency tolerance: Operating temperature range: 0.0015 percent of frequency measured at 25C. Reference temperature: 0.001 percent. Mode of oscillation: Third mechanical overtone. Operating

6、temperature range (noncontrolled): -40C to +65C, inclusive. Reference temperature: 25C. Operable temperature range: +65C to +80C, inclusive. Frequency and equivalent resistance: Method A, MIL-PRF-3098. Resonance: Series. Rated drive level: 1.0 mW, maximum. Calibration values: Resistance: 40 ohms. Cr

7、ystal current: 0.28 mA. Capacitance, shunt: 7 pF, maximum. Equivalent resistance: 40 ohms, maximum. Shock: Method 202, MIL-STD-202. Frequency change permitted: 0.0005 percent. Equivalent-resistance change permitted: 10 percent. Vibration: Method 204, MIL-STD-202, test condition A; .03 inch (0.76 mm)

8、 (.06 inch (15.24 mm) total excursion) 10 cps to 55 cps; amplitude to produce 5 gravity units, 55 cps to 500 cps. Frequency change permitted: 0.0005 percent. Equivalent-resistance change permitted: 10 percent. Aging: Frequency change permitted: 0.0005 percent. Reference documents. In addition to MIL

9、PRF-3098, this document references the following: MIL-STD-202 The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in

10、these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr

11、om IHS-,-,-MIL-PRF-3098/93C 4 Custodians: Preparing activity: Air Force - 99 DLA - CC DLA - CC (Project 5955-2009-034) Review activities: Air Force - 19, 84 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ANSI UL 61010-1-2012 UL Standard for Safety Electrical Equipment For Measurement Control and Laboratory Use Part 1 General Requirements (Third Edition Including Revisions through A.pdf ANSI UL 61010-1-2012 UL Standard for Safety Electrical Equipment For Measurement Control and Laboratory Use Part 1 General Requirements (Third Edition Including Revisions through A.pdf
  • ANSI UL 61010-2-010-2015 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-010 Particular Requirements for Laboratory.pdf ANSI UL 61010-2-010-2015 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-010 Particular Requirements for Laboratory.pdf
  • ANSI UL 61010-2-011-2017 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-011 Particular Requirements for Refrigerat.pdf ANSI UL 61010-2-011-2017 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-011 Particular Requirements for Refrigerat.pdf
  • ANSI UL 61010-2-012-2017 UL Standard for Safety Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-012 Particular Requirements for Cli.pdf ANSI UL 61010-2-012-2017 UL Standard for Safety Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-012 Particular Requirements for Cli.pdf
  • ANSI UL 61010-2-020-2016 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-020 Particular Requirements for Laboratory.pdf ANSI UL 61010-2-020-2016 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-020 Particular Requirements for Laboratory.pdf
  • ANSI UL 61010-2-030-2012 UL Standard for Safety Safety requirements for electrical equipment for measurement control and laboratory use C Part 2-030 Particular requirements for tes.pdf ANSI UL 61010-2-030-2012 UL Standard for Safety Safety requirements for electrical equipment for measurement control and laboratory use C Part 2-030 Particular requirements for tes.pdf
  • ANSI UL 61010-2-032-2014 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-032 Particular Requirements for Hand-Held .pdf ANSI UL 61010-2-032-2014 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-032 Particular Requirements for Hand-Held .pdf
  • ANSI UL 61010-2-033-2014 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-033 Particular Requirements for Hand-Held .pdf ANSI UL 61010-2-033-2014 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-033 Particular Requirements for Hand-Held .pdf
  • ANSI UL 61010-2-040-2016 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-040 Particular Requirements for Sterilizer.pdf ANSI UL 61010-2-040-2016 UL Standard for Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use C Part 2-040 Particular Requirements for Sterilizer.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1