1、AMSC N/A FSC 5945 MIL-PRF-6106/11E 17 November 2011 SUPERSEDING MIL-PRF-6106/11D 10 November 2000 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC, NORMALLY CLOSED, CONTINUOUS DUTY, 60 AMP, 3PST, ENVIRONMENTALLY SEALED This specification is approved for use by all Departments and Agencies of t
2、he Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification and the latest issue of MIL-PRF-6106. FIGURE 1. Relay, outline drawing. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,
3、-MIL-PRF-6106/11E 2 Inches mm Inches mm Inches Mm .005 0.13 .250 6.35 1.74 44.20 .010 0.25 .309 7.86 1.890 48.01.02 0.51 .375 9.53 1.900 48.26 .028 0.71 .440 11.18 2.000 50.80.032 0.81 .530 13.46 2.115 53.72 .063 1.60 .600 15.24 2.313 58.75.148 3.76 .625 15.88 2.40 60.96 .186 4.72 1.000 25.40 2.500
4、63.50.240 6.10 1.375 35.18 3.032 77.01 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .031 (0.79 mm). 4. Weights include cover, barriers, and terminal hardware. 5. When using relay at rated 60 amps, the us
5、e of lugs per Burndy part number YAEV6C-G8 or equal is recommended. 6. Terminal temperature rise under continuous current conditions is 95C maximum. FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE I
6、. Dash number and operating characteristics. Dash no. Type Coil data Time milliseconds-maximum Coil Nominal Maximum Max pickup voltage 1/ Hold voltage 1/ Drop out voltage 1/ Operate 2/ Release 3/ Bounce Volts Freq Res Volts Ampere Normal 1/ High temp test Cont current test Main Auxiliary Inrush Stea
7、dy state NO NC NO NC -001 1 X1, X2 28 DC - 29 1.25 .25 17 20 21.5 7.0 1.5 25 25 - 2 - - -002 1 X1, X2 28 DC - 29 1.25 .25 17 20 21.5 7.0 1.5 25 25 - 2 2 2 -003 1 X1, X2 115 400 - 124 .71 .1 85 95 100 40 10 55 35 - 2 - - -004 1 X1, X2 115 400 - 124 .71 .1 85 95 100 40 10 55 35 - 2 2 2 1/ Over the tem
8、perature range 2/ With nominal coil voltage 3/ From nominal coil voltage TABLE II. Rated contact load (amperes per pole) (case grounded). Type of load Life operating cycles x10328 V dc 1/ 115 V ac, 1 phase 1/ 115/200 V ac, 3 phase 1/ Main Auxiliary Main Auxiliary Main Auxiliary NO NC NO NC 400 Hz 60
9、 Hz 400 Hz 60 Hz 400 Hz 60 Hz 400 Hz 60 Hz Resistive 100 - - 3 3 60 - 3 - 60 - - - Inductive 100 - - 1.5 1.5 60 - 1.5 - 60 - - - Motor 50 - - - - 40 - - - 40 - - - Lamp - - .5 .5 - .5 - - - - Transfer load 2/ - - - - - - - Mechanical life reduced current 200 - - .75 .75 15 - .75 - 15 - - - Mixed loa
10、ds 3/ 50 - - Per spec 4 - - - 4 - - - 1/ Absence of value indicates relay is not rated for that application. 2/ Transfer load indicates relay suitable for transfer between unsynchronized ac power supplies at rating. 3/ Mixed loads to be conducted at +71C. Number of mixed loads cycles following conti
11、nuous current test - 5000.MIL-PRF-6106/11E3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/11E 4 REQUIREMENTS Weight: 001 and 002: 10 ounces maximum. 003 and 004: 11 ounces maximum. Temperature range: -55C to +71C. Maximum altitude rati
12、ng: 50,000 feet. 1/ Shock g-level: .5 sine, 25 gs. Duration: 6 to 9 ms. Maximum duration contact opening: 1 ms. Vibration-sinusoidal: See table III. TABLE III. Vibration-sinusoidal. Dash No. Vibration level 5-10 Hz 10-55 Hz 55-400 Hz 400-800 Hz 800 - 2000 Hz -55C and 25C +71C -001 .08 DA .06 DA 10 g
13、s 10 gs 10 gs 7 gs -002 10 gs 8 gs 8 gs 7 gs -003 10 gs 10 gs 10 gs 7 gs -004 10 gs 8 gs 8 gs 7 gs Vibration (random): Not applicable. Acceleration: 15 gs. Seal: Applicable specification: MIL-STD-202, method 112, test condition C, procedure IV. Leak rate: 6x10-4 std cc/s. Strength of terminals and m
14、ounting studs: Torque: Main terminals: 24 inch-pounds maximum, 18 inch-pounds recommended installation torque. Auxiliary terminals: 4.4 inch-pounds maximum, 3.3 inch-pounds recommended installation torque. Insulation resistance, initial: 200 megohms minimum. After life or environmental tests: 100 me
15、gohms minimum. 1/ Application range can be extended to 80,000 feet by suitably encapsulating the terminals. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/11E 5 Dielectric withstanding voltage (sea level): 2 to 5 seconds. Initial 28 V d
16、c 115 V ac After life tests 28 V dc 115 V ac Coil to case - - - - - - - - - - - - - - - - - - - - - 1,250 1,500 1,000 1,125 Auxiliary contacts - - - - - - - - - - - - - - - - - 1,250 1,250 1,000 1,000 Across open power contacts - - - - - - - - - 1,250 1,250 625 625 All other points - - - - - - - - -
17、 - - - - - - - - - - 1,800 1,800 1,350 1,350 Dielectric withstanding voltage (altitude): 1 minute. 28 V dc 115 V ac Coil to case - - - - - - - - - - - - - - - - - 500 500 Auxiliary contacts - - - - - - - - - - - - - 500 500 All other points - - - - - - - - - - - - - - - 700 700 Maximum contact drop,
18、 initial: .150 volt. After life test: .200 volt. Overload current: 320 amperes (ac). 1/ Rupture current: 400 amperes (ac). Duty rating: Continuous. RFI specification (applicable to coil circuits of ac operated relays): MIL-STD-461. Part number. M6106/11- (dash number from table I). Qualification by
19、similarity: See MIL-PRF-6106. Referenced documents. In addition to MIL-PRF-6106, this document references the following: MIL-STD-202 MIL-STD-461 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made.
20、This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to t
21、he last previous issue. 1/ Number of rupture cycles after mixed loads test: 5. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/11E 6 Custodian: Preparing activity: Air Force - 85 DLA - CC DLA - CC (Project 5945-2011-061)Review activities
22、: Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-