DLA MIL-PRF-6106 19 G-2011 RELAY ELECTROMAGNETIC PERMANENT MAGNET DRIVE 25 AMPERES SPDT HERMETICALLY SEALED.pdf

上传人:cleanass300 文档编号:692977 上传时间:2018-12-30 格式:PDF 页数:11 大小:131.28KB
下载 相关 举报
DLA MIL-PRF-6106 19 G-2011 RELAY ELECTROMAGNETIC PERMANENT MAGNET DRIVE 25 AMPERES SPDT HERMETICALLY SEALED.pdf_第1页
第1页 / 共11页
DLA MIL-PRF-6106 19 G-2011 RELAY ELECTROMAGNETIC PERMANENT MAGNET DRIVE 25 AMPERES SPDT HERMETICALLY SEALED.pdf_第2页
第2页 / 共11页
DLA MIL-PRF-6106 19 G-2011 RELAY ELECTROMAGNETIC PERMANENT MAGNET DRIVE 25 AMPERES SPDT HERMETICALLY SEALED.pdf_第3页
第3页 / 共11页
DLA MIL-PRF-6106 19 G-2011 RELAY ELECTROMAGNETIC PERMANENT MAGNET DRIVE 25 AMPERES SPDT HERMETICALLY SEALED.pdf_第4页
第4页 / 共11页
DLA MIL-PRF-6106 19 G-2011 RELAY ELECTROMAGNETIC PERMANENT MAGNET DRIVE 25 AMPERES SPDT HERMETICALLY SEALED.pdf_第5页
第5页 / 共11页
点击查看更多>>
资源描述

1、 AMSC N/A FSC 5945 MIL-PRF-6106/19G 18 November 2011 SUPERSEDING MIL-PRF-6106/19F 10 November 2000 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED This specification is approved for use by all Departments and Agencies of the Depart

2、ment of Defense. The requirements for acquiring the relay described herein shall consist of this specification sheet and MIL-PRF-6106. FIGURE 1. Relay, outline drawing. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 2 FIG

3、URE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 3 FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-

4、,-,-MIL-PRF-6106/19G 4 Inches mm Inches Mm Inches mm .001 0.03 .156 3.96 .525 13.34 .002 0.05 .172 4.37 .562 14.27 .003 0.08 .234 5.94 .625 15.88 .005 0.13 .250 6.35 .630 16.00 .020 0.51 .270 6.86 1.010 25.65 .040 1.02 .281 7.14 1.025 26.04 .050 1.27 .300 7.62 1.062 26.97 .062 1.57 .375 9.52 1.396 3

5、5.46 .093 2.36 .432 10.97 1.406 35.71 .100 2.54 .485 12.32 1.446 36.73 .150 3.61 .500 12.70 1.718 43.64 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. Terminal numbers need not appear on

6、 the relay header provided there is a suitable legible circuit diagram affixed to the relay that identifies each terminal location specified. 5. Relay must not operate or become damaged by reverse polarity. Semiconductors shall not be used for this purpose. 6. Hook terminals will accept one no. 12 A

7、WG stranded wire. 7. Permanent magnet drive consists of permanent magnet with its flux path switched and combined with the electromagnetic flux. 8. Socket pin terminals shall provide the operational, environmental, and interface characteristics to provide a reliable interconnect to gold-plated conta

8、cts. Terminals shall be gold plated. Gold plating of the polarizing pin is optional. One system for gold plating that may be used is ASTM B488, type 3, class 1.25 with a nickel underplate of 50 to 150 microinches thick. The gold plating system shall enable the product to meet the performance require

9、ments of this specification and shall be approved by the qualifying activity. 9. Gasket shall provide a reliable seal between the relay and mating socket that will meet the environmental, operational, and interface requirements of the relay with the mating socket. The gasket shall have shore hardnes

10、s 20 5, thickness .050 .005. Gasket material according to SAE-AMS 3332 has been considered acceptable. FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 5 TABLE I. Mechanical and electrical

11、 characteristics. Dash number Relay type Coil 1/ 2/ suppression Terminal type Mounting Configuration Coil circuit Time current relay characteristic at 25C -003 I Not applicable Solder hook A A Not applicable -004 I Not applicable Socket, pin A A Not applicable -005 I 3/ Not applicable Solder, pin A

12、A Applicable -006 I 3/ Not applicable Solder hook A A Applicable -007 I 3/ Not applicable Socket, pin A A Applicable -008 I 3/ Not applicable Solder, pin B A Applicable -009 I 3/ Not applicable Solder hook B A Applicable -010 I Not applicable Solder, pin A A Applicable -011 I Not applicable Solder h

13、ook A A Applicable -012 I Not applicable Socket, pin A A Applicable -013 I Not applicable Solder, pin B A Applicable -014 I Not applicable Solder hook B A Applicable -015 I 42 V dc, max Solder, pin A B Applicable -016 I 42 V dc, max Solder hook A B Applicable -017 I 42 V dc, max Socket, pin A B Appl

14、icable -018 I 42 V dc, max Solder, pin B B Applicable -019 I 42 V dc, max Solder hook B B Applicable -020 I 3/ 42 V dc, max Solder, pin A B Applicable -021 I 3/ 42 V dc, max Solder hook A B Applicable -022 I 3/ 42 V dc, max Socket, pin A B Applicable -023 I 3/ 42 V dc, max Solder, pin B B Applicable

15、 -024 I 3/ 42 V dc, max Solder hook B B Applicable -025 I Not applicable Solder hook B A Not applicable 1/ Relays using suppression devices shall continue to operate should the suppression circuit be in a failure mode. 2/ Diodes shall have a peak inverse voltage of 600 V dc minimum when used and sha

16、ll be JANTX or JANTX screened after 30 December 1980. 3/ Screened relays shall be tested to group A1 inspections of the group A inspection table. Additional life testing is not required. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE II. Dash

17、numbers and operating characteristics. Dash No. Coil terminal Coil data Time (milliseconds) (max) Nominal Maximum Max pickup voltage Hold voltage 2/ Dropout voltage 2/ Oper. 3/ Rel. 4/ Contact bounce Break bounce NO only 5/ Volts 1/ Freq. Hz Res. ohms 10% at 25C Volts Amp Norm 2/ High temp test Cont

18、. curr. Main Aux NO NC NO NC -003 through -025 X1 - X2 28 dc 320 29 0.11 18 19.8 22.5 7.0 1.5 10 10 1.0 1.0 - - 0.10 1/ CAUTION: Use of any coil voltage less than nominal coil voltage will compromise the operation of the relay. 2/ Over the temperature range. 3/ With nominal coil voltage. 4/ From nom

19、inal coil voltage. 5/ Applicable to dash numbers 015 through 024 only. MIL-PRF-6106/19G 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 7 REQUIREMENTS: Contact data: Load ratings: See table III. Intermediate current: Applicable. Mi

20、xed loads: Applicable. TABLE III. Rated contact load (amperes per pole) (case grounded). Type of load Endurance Life Operating cycles X 103 28 V dc 115 V ac, 1 phase 115/200 V ac, 3 phase 1/ 400 Hz 400 Hz 60 Hz Resistive 2/ 50 25 25 Inductive 10 12 - Inductive 20 - 15 Motor 50 10 10 Lamp 50 5 5 Tran

21、sfer load 3/ - - - Mechanical life reduced current 200 6 6 APPLICABLE ONLY TO DASH NOS. -003, -004, AND -025. Resistive Inductive Inductive Motor Lamp Transfer, load 3/ Mechanical life reduced current 25 - 25 25 - - 100 10 - 10 8 - - 2.5 1/ Absence of value indicates relay is not rated for 3 phase a

22、pplication. 2/ For full rated load maximum temperature and altitude, use no. 12 wire or larger. Solder hook relays to be mounted to limit mounting bracket temperature to 160C. 3/ Transfer load indicates relay suitable for transfer between unsynchronized ac power supplies at rating indicated. Provide

23、d by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 8 Life: 50,000 cycles, unless otherwise specified (see table III). Contact voltage drop or resistance: Initial contact voltage drop: 0.150 V maximum. Rated resistive current at 6 V dc or peak

24、ac. Relays shall not make or break this load. Initial contact resistance: Not applicable. High level life (contact voltage drop): During life: 10 percent open circuit voltage maximum. After life: 0.175 V maximum. Intermediate current (contact resistance): During intermediate current: 3 ohms maximum.

25、 After intermediate current: 0.150 ohm maximum. Coil data: Coil data: See table I and II. Duty rating: Continuous. Operational data: Contact ratings: See table III. Operate time: See table II. Overload current: 50 amperes dc, 80 amperes ac, 400 Hz. 1/ Rupture current: 60 amperes dc, 100 amperes ac,

26、400 Hz. 2/ Physical: Dimensions and configurations: See figure 1. Weight: 0.09 pound, 41 grams maximum. Terminal type: See figure 1 and table I. Strength of terminals and mounting studs: Applicable. Terminal solderability: Applicable to solder pin and solder-hook terminals only. _ 1/ For -003, -004,

27、 and -025, 20 amperes ac, 60 Hz. 2/ Not applicable to -003, -004 and -025. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 9 ENVIRONMENTAL DATA: Temperature range: -70C to +125C. 1/ Altitude rating: 300,000 feet maximum. Shock: 200 g

28、s. Duration: 6 ms. Duration contact opening: 10 microseconds maximum. Vibration - sinusoidal: 30 gs. Frequency range: 10 to 3,000 Hz. Random vibration: MIL-STD-202, method 214, test condition IG. Duration: 15 minutes each plane. Acceleration: 15 gs. Insulation resistance, initial: 100 megohms. After

29、 life or environmental tests: 50 megohms. Dielectric withstanding voltage (sea level): Initial After life test Coil to case 1,000 V rms 1,000 V rms All other points 1,250 V rms 1,000 V rms Dielectric withstanding voltage (altitude): 2/ 80,000 feet 300,000 feet Coil to case 350 V rms 500 V rms All ot

30、her points 350 V rms 500 V rms Qualification by similarity: See MIL-PRF-6106. Part or Identifying Number (PIN). M6106/19- (dash number from table I). _ 1/ For full rated load maximum temperature and altitude, use no. 12 wire or larger, solder hook relays shall be mounted to limit mounting bracket te

31、mperature to 160C. This note is not applicable to -003, -004, and -025 and the requirements of MIL-PRF-6106 for temperature and wire size shall apply. 2/ Dielectric withstanding voltage rating may be improved by suitable insulation of terminals and wiring after installation. Plug in relays with suit

32、able gasket compressed will have dielectric withstanding voltage capabilities at 80,000 feet over 500 V rms. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 10 TABLE IV. Time current relay characteristics at 25C. 1/ 2/ 3/ Amperes Dur

33、ation 30 1 hour 50 5.0 seconds100 1.2 seconds250 0.2 second 350 0.1 second1/ Applicable to dash numbers-005 through -024. 2/ CAUTION: Compare with time current characteristics of the associated circuit protective device. 3/ Dash nos. -005 through -024. Relays shall sustain five applications (make an

34、d carry only) of power at each of five different current levels for the time durations in table IV. Separate relays shall be tested at 28 V dc and 115 V ac, 400 Hz. Cooling time between successive applications shall be 30 minutes. The test shall be performed on both normally open and normally closed

35、 contacts of each relay. There shall be no failures or evidence of welding or sticking and relays shall pass contact voltage drop at conclusion. Cross reference for Government logistical support. See table V. TABLE V. Cross reference for Government logistical support. PIN M6106/19- Support with PIN

36、M6106/19- PIN M6106/19- Support with PIN M6106/19 003 003 015 020004 004 016 021005 020 017 022 006 021 018 023007 022 019 024008 023 020 020 009 024 021 021010 020 022 022011 021 023 023 012 022 024 024013 023 025 025014 024 Supersession data: See table VI. TABLE VI. Supersession data. Superseded P

37、IN M6106/19- New PIN M6106/19- 001 011002 012 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 11 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previou

38、s issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations an

39、d relationship to the last previous issue Referenced documents. In addition to MIL-PRF-6106, this document references the following: MIL-STD-202 ASTM B488 SAE- AMS 3332 Custodians: Preparing activity: Air Force - 85 DLA - CC DLA - CC (Project 5945-2011-064) Review activities: Air Force - 99 NOTE: Th

40、e activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1