1、INCH-POUND MIL-PRF-8805/3L 23 March 2009 SUPERSEDING MIL-PRF-8805/K 14 March 2003 PERFORMANCE SPECIFICATION SHEET SWITCHES, PUSH, 10 AMPERES OR LOW LEVEL, DUSTTIGHT This specification is approved for use by all Departments and Agencies of the Department of Defense. The complete requirements for acqu
2、iring the switches described herein shall consist of this specification and the latest issue of MIL-PRF-8805. FIGURE 1. Configuration and dimensions.625 .006 DIA BUTTON STYLE SHOWN IS FOR MOMENTARY ACTION SWITCHES (SEE PUSH-PULL CONFIGURATION) AMSC N/A FSC 5930 Provided by IHSNot for ResaleNo reprod
3、uction or networking permitted without license from IHS-,-,-MIL-PRF-8805/3L 2 .375 Inches mm Inches mm Inches mm Inches mm .001 0.03 .031 0.79 .250 6.35 .623 15.82 .004 0.10 .047 1.19 .312 7.92 .625 15.88 .006 0.15 .062 1.57 .333 8.46 .640 16.26 .015 0.38 .094 2.39 .375 9.53 .688 17.48 .016 0.41 .12
4、5 3.18 .438 11.13 .739 18.77 .019 0.48 .156 3.96 .500 12.70 .875 22.23 .020 0.51 .187 4.75 .562 14.27 1.375 34.93 .022 0.56 .188 4.78 NOTES: 1. Dimensions are in inches. 2. Unless otherwise stated, tolerance is .010 (0.25 mm). 3. Mounting thread .625-24 UNEF-2A applies to type C, F, G, and H. All th
5、reads to be within .10 2.54 mm) of shoulder. 4. All terminal threads are .086-56UNC-28. 5. Hardware for each terminal includes one screw, one terminal lug, and one lockwasher. 6. Types C, F, G, and H shall be furnished with suitable mounting hardware. 7. Overall height of switch with push-pull activ
6、ator is 1.530 (38.66 mm) maximum in extended position. 8. Metric equivalents are given for general information only. 9. For push-pull configuration, circuit schematic is shown with actuator in extended position. FIGURE 1. Configuration and dimensions - Continued.Provided by IHSNot for ResaleNo repro
7、duction or networking permitted without license from IHS-,-,-MIL-PRF-8805/3L 3 REQUIREMENTS: Dimensions and configuration: See figure 1. Enclosure design: 2 (dust-tight). Temperature characteristic: 1 (-55C to +85C). Shock type: H for monetary type only (no contact opening or closing in excess of 20
8、 milliseconds). M for other units. Sinusoidal vibration grade: 2 (10 to 2,000 Hz). Weight: .050 pound maximum. Solderability: Applicable to screw tabs and solder lugs. Operating characteristics: Total plunger travel: .085 .015 inch. Operating force: Momentary: 4 1 pounds. Push-pull: 0.5 to 2 pounds.
9、 Releasing force: 1 pound minimum, monetary. Terminal strength torque test: Not applicable. Strength of actuator and stop: 75 pounds for 3 terminals circuitry; 40 pounds for all others. Finish: The switch case shall be corrosion resistant , lusterless black. Dielectric withstanding voltage: Sea leve
10、l: 1,000 V rms. After electrical endurance: 200 V rms. Intermediate current: 1/ MS25089-1, MS25089-2, and MS25089-3: 200,000 cycles. MS25089-4 and MS25089-5: 50, 000 cycles. 1/ Prior to test, units preconditioned at 85C for 48 hours. Provided by IHSNot for ResaleNo reproduction or networking permitt
11、ed without license from IHS-,-,-MIL-PRF-8805/3L 4 Mechanical endurance (10 to 15 cpm): MS25089-1, MS25089-2, and MS25089-3: At room temperature: 200,000 cycles. At -55C and +85C: 100,000 cycles each. MS25089-4 and MS25089-5: 50,000 cycles. Electrical endurance: 25,000 cycles at sea level; 5,000 cycl
12、es at 50,000 feet. Electrical ratings: Central terminal ratings: 3 amperes maximum. Other than center terminals: See table I. TABLE I. Electrical ratings, power circuit switches. 1/ Sea level 50,000 feet Load 28 V dc 115/V ac, 60/400 Hz 28 V dc Amperes Amperes Amperes Resistive- 10 10 - - - Inductiv
13、e - 5 5 5 Lamp - 3 3 - - - 1/ Center terminal rating: 3 amperes maximum. 2/ The 400 Hz ratings are shown for information only and do not require electrical endurance testing. Sand and dust: Applicable. Electrical logic circuit (5.0 V dc, .010 ampere): Applicable when specified (see table II): 25,000
14、 cycles at an actuation rate of 120 cycles per minute maximum with no “stick“, or “misses“, allowed when tested in accordance with EIA RS448, method 17 as follows: Test condition: Each switch contact shall be tested using a 5.0 0.5 V dc, 10 1 mA resistive load. During each closure of the contacts, t
15、he voltage drop across the switch terminals shall be monitored for a duration of no less than 50 percent of each contact static closure. The switch contacts need not be monitored until 10 milliseconds after the initial contact closure to exclude any contact bounce. During each opening of the contact
16、s, the voltage drop across the switch terminals shall be monitored for a duration of no less thn 50 percent of each contact opening. A voltage of 2.1 volts or greater across the switch terminals shall constitute a contact “miss“ (failure to properly close the circuit). A voltage drop of less than 90
17、 percent of the open-circuit voltage shall constitute a contact “stick“ (failure to properly open the circuit). The monitoring device shall either record the number of contact closures at which “sticks“ and/or “misses“ occur, or discontinue the test when “sticks“ and/or “misses“ occur. Operating tem
18、perature: a. 25 percent of the test cycle at -55C specified. b. 25 percent of the test cycle at room ambient conditions. c. 50 percent of the test cycle at +85C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-8805/3L 5 Qualification: Group s
19、ubmission: See table III. Group A inspection: When low level circuit applies, switches shall not be subjected to loads greater than 100 milliamperes at an open circuit voltage of 6 volts maximum dc or peak ac. Part number: See table II. TABLE II. Part numbers and characteristics. Momentary action sw
20、itches Push-pull switches Button color Button color Type Black Red White Black Red White Switch circuit 1A 1AR 1AW NO 2A 2AR 2AW NC 3A 3AR 3AW 2 circuit 4A 4AR 4AW 3 term NO A 5A 5AR 5AW None 3 term NC 1B 1BR 1BW NO 2B 2BR 2BW NC 3B 3BR 3BW 2 circuit 4B 4BR 4BW 3 term NO B 5B 5BR 5BW None 3 term NC
21、1C 1CR 1CW 1C-1 1CR-1 1CW-1 NO 2C 2CR 2CW 2C-1 2CR-1 2CW-1 NC 3C 3CR 3CW 3C-1 3CR-1 3CW-1 2 circuit 4C 4CR 4CW 4C-1 4CR-1 4CW-1 3 term NO C 5C 5CR 5CW 5C-1 5CR-1 5CW-1 3 term NC 1E 1ER 1EW NO 2E 2ER 2EW NC 3E 3ER 3EW 2 circuit 4E 4ER 4EW 3 term NO E 5E 5ER 5EW None 3 term NC 1F 1FR 1FW 1F-1 1FR-1 1F
22、W-1 NO 2F 2FR 2FW 2F-1 2FR-1 2FW-1 NC 3F 3FR 3FW 3F-1 3FR-1 3FW-1 2 circuit 4F 4FR 4FW 4F-1 4FR-1 4FW-1 3 term NO F 5F 5FR 5FW 5F-1 5FR-1 5FW-1 3 term NC 1G 1GR 1GW 1G-1 1GR-1 1GW-1 NO 2G 2GR 2GW 2G-1 2GR-1 2GW-1 NC 3G 3GR 3GW 3G-1 3GR-1 3GW-1 2 circuit 4G 4GR 4GW 4G-1 4GR-1 4GW-1 3 term NO G 5G 5GR
23、 5GW 5G-1 5GR-1 5GW-1 3 term NC 1H 1HR 1HW 1H-1 1HR-1 1HW-1 NO 2H 2HR 2HW 2H-1 2HR-1 2HW-1 NC 3H 3HR 3HW 3H-1 3HR-1 3HW-1 2 circuit 4H 4HR 4HW 4H-1 4HR-1 4HW-1 3 term NO H 5H 5HR 5HW 5H-1 5HR-1 5HW-1 3 term NC 1/ Low level circuit and electronic logic circuit does not apply for dash numbers shown. T
24、o specify switches with low circuit and electronic logic circuit applicable, add the letter “L“ to the dash number. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-8805/3L 6 Examples of part numbers: MS25089-4C = Switch, Push, Dusttight, 3 Te
25、rminal (NO), Type C, Momentary, Black Button. MS25089-4CR-1 = Switch, Push, Dusttight, 3 Terminal (NO), Type C, Push-Pull, Red Button. MS25089-4CL = As above, except low level circuit and electronic logic circuit applies. Power circuit electrical ratings do not apply. MS25089-4CR-1L = As above, exce
26、pt low level circuit and electronic logic circuit applies. Power circuit electrical ratings do not apply. TABLE III. Qualification inspection. Examination or test Basic switch Other switch samples Extent of approval Qualification 1/ inspection table of MIL-PRF-8805 Required sample units of any 2 cir
27、cuit configurations 2/ Required number of sample units of 3 terminal NO or 3 terminal NC (groups VII and x tests, qualification inspection table, MIL-PRF-8805 plus 2 additional sample units shall be subjected to electronic logic circuit test and operating characteristics) 2/ All In addition, 2 sampl
28、e units of each of the other configurations shown on this specification sheet shall be submitted. Visual and mechanical examination. 1/ Electrical endurance tests shall be performed at 28 V dc and 115 V ac, 60 Hz only. 2/ One-half of sample units shall be momentary and one-half shall be push-pull. P
29、rovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-8805/3L 7 The margins of this specification are marked with vertical lines to indicate where modifications from this amendment were made. This was done as a convenience only and the Government as
30、sumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations. Referenced documents: MIL-PRF-8805 EIA RS448 Custodians: Preparing activity:
31、Army - CR DLA - CC Navy - EC Air Force - 85 (Project 5930-2009-012) DLA - CC Review activities: Air Force - 19, 99 Army - AR, AV, MI Navy - AS, MC, OS, SH NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-