1、AMSC N/A FSC 5930 INCH-POUND MS14003J 5 October 2011 SUPERSEDING MS14003H 30 September 1986 DETAIL SPECIFICATION SHEET SWITCH, TOGGLE, POSITIVE BREAK, ENVIRONMENTALLY SEALED, SOLDER LUG, FOUR POLE, .469 MOUNTING BUSHING, 25 AMPERES This specification is approved for use by all Departments and Agenci
2、es of the Department of Defense. The requirements for acquiring the products described herein shall consist of this specification sheet and MIL-DTL-8834. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are .0
3、10 (0.25 mm) on decimals and 5 on angles. FIGURE 1. Dimensions and configuration. Inches mm Inches mm .005 .010 .012 .030 .032 .072 .115 .135 0.13 0.25 0.30 0.76 0.81 1.83 2.92 3.43 .240 .432 .469 .687 1.328 1.336 1.686 6.10 10.97 11.91 17.45 33.73 33.93 42.82 Provided by IHSNot for ResaleNo reprodu
4、ction or networking permitted without license from IHS-,-,-MS14003J 2 REQUIREMENTS: For hardware detail specifications, see appendix of MIL-DTL-8834. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedenc
5、e. For design feature purposes, this specification takes precedence over acquisition documents referenced herein. . Configuration of switch case housing, terminals, and barrier: design optional providing maximum dimensions specified are not exceeded. Weight: .175 pound maximum (79.4 grams). Altitude
6、 requirements: 80,000 feet. 115 V ac 60 hertz electrical endurance tests are to be performed at room temperature and pressure. . Contact bounce: Shall not exceed 3.5 milliseconds. TABLE I. Detail requirements. MS dash no Circuits made between terminals as indicated with the toggle lever in these pos
7、itions: Current capacity amperes per pole 28 volts dc 1/ Current capacity amperes per pole 1/ 115 volts 400 hertz ac Current capacity amperes per pole 1/ 115 volts 60 hertz ac Opposite keyway side Center position Keyway side Lamp load circuit Resis- tive circuit Induct- ive circuit Lamp load circuit
8、 Resis- tive circuit Induct- ive circuit Lamp load circuit Resis- tive circuit Induct- ive circuit -212 on 2-3, 5-6 8-9, 11-12 off on 1-2, 4-5 7-8, 10-11 7 25 15 7 25 15 7 20 15 -222 none off -232 on 1-2, 4-5 7-8, 10-11 -242 off none -262 none mom-on 1-2, 4-5 7-9, 10-11 -272 mom-on 2-3, 5-6 8-9, 11-
9、12 off -282 none -292 on 2-3, 5-6 8-9, 11-12 none mom-off -302 off mom-on 1-2, 4-5 7-8, 10-11 -312 on 2-3, 5-6 8-9, 11-12 off See footnote at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS14003J 3 TABLE I. Detail requirements - Cont
10、inued. MS dash no Current capacity amperes per pole 1/ 250 volts 60 hertz ac Current capacity amperes per pole 1/ 125 volts dc Current capacity amperes per pole 1/ 250 volts dc Life low current level switching 30 mV Lamp load circuit Resis- tive circuit Induct- ive circuit Lamp load circuit Resis- t
11、ive circuit Induct- ive circuit Lamp load circuit Resis- tive circuit Induct- ive circuit -212 10 7 750 mA 500 mA 10 mA -222 -232 -242 -262 -272 -282 -292 -302 -312 1/ Application information ratings at room temperature. Referenced documents: MIL-DTL-8834 Changes from previous issue. Marginal notati
12、ons are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing activity: Army CR DLA CC Navy AS Air Force 85 (Project 5930-2011-072) DLA - CC Review activities: Army - AR, MI Navy - EC Air Force - 99 NOTE: The activiti
13、es listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-