DLA MS25467 REV E-2003 RELAYS ELECTROMAGNETIC 5 AMPERES 4 PDT TYPE I MAGNETIC LATCH SOLDER TERMINAL STUD MOUNTED HERMETICALLY SEALED《I型4 PDT 5安培焊接终端栓钉安装磁力锁密封电磁继电器》.pdf

上传人:lawfemale396 文档编号:696576 上传时间:2019-01-02 格式:PDF 页数:5 大小:56.64KB
下载 相关 举报
DLA MS25467 REV E-2003 RELAYS ELECTROMAGNETIC 5 AMPERES 4 PDT TYPE I MAGNETIC LATCH SOLDER TERMINAL STUD MOUNTED HERMETICALLY SEALED《I型4 PDT 5安培焊接终端栓钉安装磁力锁密封电磁继电器》.pdf_第1页
第1页 / 共5页
DLA MS25467 REV E-2003 RELAYS ELECTROMAGNETIC 5 AMPERES 4 PDT TYPE I MAGNETIC LATCH SOLDER TERMINAL STUD MOUNTED HERMETICALLY SEALED《I型4 PDT 5安培焊接终端栓钉安装磁力锁密封电磁继电器》.pdf_第2页
第2页 / 共5页
DLA MS25467 REV E-2003 RELAYS ELECTROMAGNETIC 5 AMPERES 4 PDT TYPE I MAGNETIC LATCH SOLDER TERMINAL STUD MOUNTED HERMETICALLY SEALED《I型4 PDT 5安培焊接终端栓钉安装磁力锁密封电磁继电器》.pdf_第3页
第3页 / 共5页
DLA MS25467 REV E-2003 RELAYS ELECTROMAGNETIC 5 AMPERES 4 PDT TYPE I MAGNETIC LATCH SOLDER TERMINAL STUD MOUNTED HERMETICALLY SEALED《I型4 PDT 5安培焊接终端栓钉安装磁力锁密封电磁继电器》.pdf_第4页
第4页 / 共5页
DLA MS25467 REV E-2003 RELAYS ELECTROMAGNETIC 5 AMPERES 4 PDT TYPE I MAGNETIC LATCH SOLDER TERMINAL STUD MOUNTED HERMETICALLY SEALED《I型4 PDT 5安培焊接终端栓钉安装磁力锁密封电磁继电器》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC N/A 1 of 5 FSC 5945 INCH-POUND MS25467E 27 November 2003 SUPERSEDING MS25467D 5 Jun 1987 DETAIL SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 5 AMPERES, 4 PDT TYPE I, MAGNETIC LATCH, SOLDER TERMINAL, STUD MOUNTED, HERMETICALLY SEALED INACTIVE FOR NEW DESIGN. NO LONGER USED EXCEPT FOR REPLACEMEN

2、T PURPOSES. This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification and the latest issue of MIL-PRF-6106. FIGURE 1. Dimensions and configurations. Provided by IH

3、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25467E 2 NOTES: 1/ Dimensions are in inches. 2/ Metric equivalents are given for general information only. 3/ Unless otherwise specified, tolerance is .010 (0.25 mm). 4/ Terminal numbers need not appear on relay he

4、aders provided there is affixed to the relay a suitable legible circuit diagram that permanently and positively identifies each terminal location specified hereon. 5/ The use of diodes on ac relays is optional. Actual application must be shown on label. 6/ Shock, vibration, and acceleration requirem

5、ents application with coils de-energized 7/ Relay is magnetically latched in both positions. 8/ Caution note to observe polarity must appear on relays with dc coils. 9/ In the event of conflict between the text of this specification and the references cited herein, the text of this standard shall ta

6、ke precedence. 10/ Referenced Government documents of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DoDISS) specified in the solicitation form a part of this standard to the extent specified herein. TABLE I. Dash numbers and characteristics. Dash

7、number MS25467- Type Coil Terminal type Mounting or mating socket Max weight in pounds D1 I dc Solder hook Stud 0.30 A1 I ac Solder hook Stud 0.32 FIGURE 1.Dimensions and configurations - Continued. Inches mm .000 0.00.001 0.03 .005 0.13.031 0.79 .040 1.02.062 1.57 .152 3.86.187 4.75 .375 9.53.687 1

8、7.45 .750 19.051.032 26.21 1.187 30.15 1.531 38.89 1.812 46.02 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25467E 3 TABLE II. Operating characteristics. Coil data Time - milliseconds max Rated Max Max pick-up voltage Contact Bounce Main Aux MS

9、part no. MS25467- Coil Volts 1/ Freq Hz Res 10% Volts Amp Nor- mal 3/ High temptest Cont cur-rent test Drop out vol-tage Op-erate 4/ Rel-ease 5/ NO NC NO NC D1 X1, X2 Y1, Y2 28 dc N/A 29 0.17 18 18 19.8 N/A 25 N/A 2 2 N/A N/A A1 X1, X2 Y1, Y2 115 400 2/ N/A 122 0.07 90 90 95 N/A 25 N/A 2 2 N/A N/A 1

10、/ CAUTION: Use of any coil voltage less than rated coil voltage will compromise the operation of the relay. 2/ MS25467-A1 may be used on 60 Hz if maximum ambient temperature is limited to +85C (maximum coil current shall be 0.077 ampere). 3/ Over the temperature range. 4/ With nominal coil voltage.

11、5/ From nominal coil voltage. TABLE II. Rated contact load (amperes per pole) (case grounded). 28 V dc 115 V ac, 1 phase 115/200 V ac, 3 phase 1/ Main Aux Main Aux Main Aux Type of load Life operating cycles x 103NO NC NO NC 400 Hz 60 Hz 400 Hz 60 Hz 400 Hz 60 Hz 400 Hz 60 Hz See appropriate notes R

12、esistive 100 5 5 5 4 Inductive 100 Inductive 20 3 3 3 2 Motor 100 1.5 1.5 1.5 1 Lamp 100 0.8 0.8 0.8 0.6 Transfer load 2/ Mechanical life reduced current 400 1.25 1.25 1.25 2 Mixed loads Applicable per specification 1/ Absence of value indicates relay is not rated for 3-phase application. 2/ Transfe

13、r load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25467E 4 Environmental characteristics. Temperature range -70C to +125C Max altitude rating

14、 80,000 ft Shock G-level 50 gs Duration 11 ms Max duration contact opening 10 s Vibration - sinusoidal G-level 10 gs Frequency range 5-1,500 Hz Acceleration 15 gs Electrical characteristics. Insulation resistance: Initial 100 megohms. After life or environmental tests 50 megohms. Dielectric strength

15、 (sea level). Initial After life tests Coil to case 1,000 V rms 1,000 V rms Aux contacts All other points 1,000 V rms 1,000 V rms Dielectric strength (altitude). (When mounted in mating socket) 80,000 ft Coil to case 250 V rms Aux contacts All other points 250 V rms Max contact drop initial 0.150 vo

16、lt. After life test 0.175 volt. Overload current 20 amperes. Rupture current 25 amperes. Duty rating Continuous. RFI specification MIL-STD-461. (Applicable to coil circuits of ac operated relays.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS254

17、67E 5 Group A acceptance reports shall be submitted to the preparing activity on a yearly basis in order to retain qualification for this military specification sheet. Groups B and C inspections may be suspended at the discretion of the qualifying activity. Qualification by similarity: See MIL-PRF-6

18、106. Custodians: Preparing activity:Navy - AS DLA - CC Air Force - 11 DLA - CC (Project 5945-1214-14) Review activities: Navy - EC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using ASSIST Online database at www.dodssp.daps.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS EN 61854-1998 Overhead lines - Requirements and tests for spacers《架空线 隔离件的要求和试验》.pdf BS EN 61854-1998 Overhead lines - Requirements and tests for spacers《架空线 隔离件的要求和试验》.pdf
  • BS EN 61855-2003 Household electrical hair care appliances - Methods of measuring the performance《家用电动护发用具 性能的测量方法》.pdf BS EN 61855-2003 Household electrical hair care appliances - Methods of measuring the performance《家用电动护发用具 性能的测量方法》.pdf
  • BS EN 61857-1-2009 Electrical insulation systems – nProcedures for thermal nevaluation — nPart 1 General requirements – Low-voltage《电气绝缘系统 热评估过程 低电压一般要求》.pdf BS EN 61857-1-2009 Electrical insulation systems – nProcedures for thermal nevaluation — nPart 1 General requirements – Low-voltage《电气绝缘系统 热评估过程 低电压一般要求》.pdf
  • BS EN 61857-21-2009 Electrical insulation systems - Procedures for thermal evaluation - Specific requirements for general-purpose models - Wire-wound applications《电气绝缘系统 热评定规程 通用模式.pdf BS EN 61857-21-2009 Electrical insulation systems - Procedures for thermal evaluation - Specific requirements for general-purpose models - Wire-wound applications《电气绝缘系统 热评定规程 通用模式.pdf
  • BS EN 61857-22-2008 Electrical insulation systems - Procedures for thermal evaluation - Specific requirements for encapsulated-coil model - Wire-wound electrical insulation system .pdf BS EN 61857-22-2008 Electrical insulation systems - Procedures for thermal evaluation - Specific requirements for encapsulated-coil model - Wire-wound electrical insulation system .pdf
  • BS EN 61857-31-2017 Electrical insulation systems Procedures for thermal evaluation Applications with a designed life of 5 000 h or less《电气绝缘系统 热评估规程 5000个小时及以下设计寿命应用》.pdf BS EN 61857-31-2017 Electrical insulation systems Procedures for thermal evaluation Applications with a designed life of 5 000 h or less《电气绝缘系统 热评估规程 5000个小时及以下设计寿命应用》.pdf
  • BS EN 61858-1-2014 Electrical insulation systems Thermal evaluation of modifications to an established electrical insulation system (EIS) Wire-wound winding EIS《电气绝缘系统 对现有电气绝缘系统(EI.pdf BS EN 61858-1-2014 Electrical insulation systems Thermal evaluation of modifications to an established electrical insulation system (EIS) Wire-wound winding EIS《电气绝缘系统 对现有电气绝缘系统(EI.pdf
  • BS EN 61858-2-2014 Electrical insulation systems Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS《电气绝缘系统 对现有电气绝缘系统(EIS)改造的热评估.pdf BS EN 61858-2-2014 Electrical insulation systems Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS《电气绝缘系统 对现有电气绝缘系统(EIS)改造的热评估.pdf