1、AMSC N/A FSC 6145 MS27110E 19 October 2011 SUPERSEDING MS27110D 19 July 2004 DETAIL SPECIFICATION SHEET WIRE, ELECTRICAL - SILICONE INSULATED, COPPER, 600 VOLT, 200C, FEP JACKET This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for

2、acquiring the product described herein shall consist of this specification sheet and MIL-DTL-8777. FIGURE 1. Cable. INCH-POUND Inactive for new design after 1 June 1998. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27110E 2 TABLE I. Performance

3、details. Abrasion test Flaws test Insulation and surface resistance Life cycle and cold bend Wire size Resistance,inchesoftape min.Tension load lbs.WeightsupportbracketWeightlbs.Min ac voltage 60 Hz rms Humidityresistance megohmsper200 feetmin.Insulation resistance megohmsper50 feetmin.Surface resis

4、tance megohminchesminMandrel diameter Testload life cycle cold bend lbs.PrimaryinsulationFinished wireLifecycleCold bend22 22 1 A 1 2000 5000 3000 1000 100 4.5 3 .75 20 22 1 A 1 2000 5000 3000 1000 100 4.5 3 .75 18 22 1 A 1 2000 5000 3000 1000 100 6.5 3 1 16 30 2 A 1 2000 5000 3000 1000 100 6.5 3 1

5、14 13 2 B 3 2000 5000 3000 1000 100 6.5 6 1 12 17 2 B 3 2000 5000 3000 1000 100 6.5 6 3 10 20 2 B 3 3000 5000 10 6 3 8 25 2 B 3 3000 5000 10 6 3 6 25 2 C 3 4000 5000 10 10 6 4 33 2 C 4.25 4000 5000 10 10 6 TABLE II. Finished wire construction. Dash Wire size Number of strands Resistance at 20C (68F)

6、 ohms/1000 feet max. Finished wire diameter nominal FEP jacket thickness nominal Weight finished wire lbs/1000 ft. max. 22 22 19 15.2 .086 .004 .007 + .002, .001 7.1 20 20 19 9.42 .096 .004 .007 + .002, .001 9.0 18 18 19 6.03 .108 .004 .007 + .002, .001 12.1 16 16 19 4.76 .116 .004 .007 + .002, .001

7、 14.3 14 14 19 2.99 .141 .004 .008 + .002, .001 21.5 12 12 19 1.88 .160 .005 .008 + .002, .001 30.5 10 10 49 1.16 .194 .005 .008 + .002, .001 48.0 8 8 133 .70 .243 .007 .010 .002 75.0 6 6 133 .436 .292 .007 .010 .002 114.0 4 4 133 .274 .357 .007 .010 .002 173.0 TABLE III. Dimensions. Inches mm Inche

8、s mm .001 .03 .108 2.74 .002 .05 .116 2.95 .004 .10 .141 3.58 .005 .13 .160 4.06 .007 .18 .194 4.93 .008 .20 .243 6.17 .010 .25 .292 7.42 .086 2.18 .357 9.07 .096 2.44 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27110E 3 REQUIREMENTS The procur

9、ement specification for items described in this specification sheet is MIL-DTL-8777. Dimensions are in inches. Metric equivalents are given for information only. Dimensions and configuration: See figure 1 and tables I, II and III. Tensile strength (minimum): 800 psi before aging; 600 psi after aging

10、. Elongation (minimum): 1.5 inches (38 mm) for a 2 inch (51 mm) specimen stretched to 3.5 inches, (89 mm) before and after aging. Insulation shrinkage: During and following the thermal shock test, none of the insulation shall shrink back or flare greater then .060 inch (1.52 mm) for wire sizes 22 to

11、 12, and .125 inch (3.18 mm) for wire sizes 10 to 4. Test sample requirements: Two 24-inch (610 mm) samples shall be taken from each reel of finished wire, or 25,000 feet (7620 mm), whichever is less. The samples shall be placed on mandrels with weights attached as specified for the life cycle test

12、and subjected to 200 5C for 20 hours. Following the air open test, the samples shall be cooled for one hour and subjected to the bend tests and the dielectric tests of MIL-DTL-8777. During these tests, the outer jacket shall not shrink more than .125 inch (3.18 mm) from each end. Marking: Marking on

13、 inner braid in accordance with MIL-DTL-8777 shall be visable throught the outer FEP jacket. Part or Identifying Number (PIN) example: MS27110 - 10 MS specification sheet number Dash number Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect

14、 to the previous issue due to the extent of the changes. Referenced documents. In addition to MIL-DTL-8777, this document references the following: MIL-Y-1140 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27110E 4 CONCLUDING MATERIAL Custodians:

15、Preparing activity: Army - AV DLA - CC Navy - AS Air Force 85 (Project 6145-2011-022) DLA - CC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-