1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Added case outline Z package. Rewrote entire document. 95-04-11 K. A. Cottongim B Figure 1, case outline Z, changed the S dimension min and max limits. Deleted figure 3, block diagram. Editorial changes throughout. 00-07-17 Raymond Monnin C Drawi

2、ng updated to reflect current requirements. -sld 04-02-18 Raymond Monnin D Table II, add note to Group C end-point test parameters. Update boilerplate paragraphs. -gz 11-12-01 Charles F. Saffle REV SHEET REV SHEET REV STATUS REV D D D D D D D D D D D OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 PMIC N/A

3、PREPARED BY Steve L. Duncan DLA LAND AND MARITIME STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C. Jones COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE APPROVED BY Kendall A. Cottongim MICR

4、OCIRCUIT, HYBRID, LINEAR, 12 VOLT, SINGLE CHANNEL, DC/DC CONVERTER DRAWING APPROVAL DATE 94-02-28 AMSC N/A REVISION LEVEL D SIZE A CAGE CODE 67268 5962-94568 SHEET 1 OF 11 DSCC FORM 2233 APR 97 5962-E089-12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS

5、-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94568 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and

6、 lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 94568 01 H X X Federal RHA Device Device Case Le

7、ad stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with

8、the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type. The device type identify the circuit function as follows: Device type Generic number Circuit function 01 AHF2812S/CH, AHF2812SF/CH DC/DC converter, 12 W, 12 V output 1.2.3 Device class designator. This device c

9、lass designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device

10、 class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing versio

11、n of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C, and D).

12、E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) ta

13、ken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without licens

14、e from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94568 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outlines. The case outlines are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Packa

15、ge style X See figure 1 8 Dual-in-line Z See figure 1 8 Flange package 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range . -0.5 V dc to +50 V dc Power dissipation (PD) 6 W Lead temperature (soldering, 10 seconds) . +300C S

16、torage temperature range. -65C to +150C 1.4 Recommended operating conditions. Input voltage range . +16 V dc to +40 V dc Output power 2/ . 12 W Case operating temperature range (TC) . -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specific

17、ation, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for.

18、DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of

19、 these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cit

20、ed herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the maximum

21、 levels may degrade performance and affect reliability. 2/ Derate output power linearly above case temperature +125C to 0 at +135C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94568 DLA LAND AND MARITIME

22、COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 4 DSCC FORM 2234 APR 97 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of al

23、l tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as defined in MIL-PRF-38534 shall be me

24、t for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of the device for the applicable device class. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL

25、-PRF-38534 and herein. 3.2.1 Case outlines. The case outlines shall be in accordance with 1.2.4 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical p

26、erformance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are defined in table I.

27、3.5 Marking of devices. Marking of devices shall be in accordance with MIL-PRF-38534. The device shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers vendor similar PIN may also be marked. 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, th

28、e manufacturer of the device described herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those wh

29、ich, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be made available to the preparing activity (DLA Land and Maritime-VA) upon request. 3.7 Certificate of compliance. A certificate of compliance shall be required from a manufactur

30、er in order to supply to this drawing. The certificate of compliance (original copy) submitted to DLA Land and Maritime-VA shall affirm that the manufacturers product meets the performance requirements of MIL-PRF-38534 and herein. 3.8 Certificate of conformance. A certificate of conformance as requi

31、red in MIL-PRF-38534 shall be provided with each lot of microcircuits delivered to this drawing. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as modified in the device manufacturers Quality Management (QM) plan. The modi

32、fication in the QM plan shall not affect the form, fit, or function as described herein. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94568 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D

33、SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions -55C TC+125C VIN= 28 V dc 5%, CL= 0 unless otherwise specified Group A subgroups Device type Limits Unit Min Max Output voltage VOUTIOUT= 0 1 01 11.88 12.12 V 2,3 11.76 12.24 Output current 1/ IOUTV

34、IN = 16, 28, and 40 V dc 1,2,3 01 1000 mA Output ripple voltage 2/ VRIPVIN = 16, 28, and 40 V dc B.W.= 20 Hz to 2 MHz 1,2,3 01 60 mVp-p Line regulation VRLINEVIN = 16, 28, and 40 V dc IOUT= 0, 500, and 1000 mA 1,2,3 01 50 mV Load regulation VRLOADVIN = 16, 28, and 40 V dc IOUT= 0, 500, and 1000 mA 1

35、,2,3 01 50 mV Input current IINIOUT= 0, inhibit (pin 1) tied to input return (pin 7) 1,2,3 01 12 mA IOUT= 0, inhibit (pin 1) = open 50 Input ripple current 2/ IRIPIOUT= 1000 mA B.W.= 20 Hz to 2 MHz 1,2,3 01 50 mA p-p Efficiency EFFIOUT= 1000 mA 1 01 78 % 2,3 75 Isolation ISO Input to output or any p

36、in to case (except pin 6) at 500 V dc, TC= +25C 1 01 100 M Capacitive load 3/ 4/ CLNo effect on dc performance, TC= +25C 4 01 200 F Power dissipation load fault PDOverload 5/ TC= +25C 1 01 6 W Short circuit 1,2,3 2 Switching frequency FSIOUT= 1000 mA 4,5,6 01 500 600 kHz See footnotes at end of tabl

37、e. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94568 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 6 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Contin

38、ued. Test Symbol Conditions -55C TC+125C VIN= 28 V dc 5%, CL= 0 unless otherwise specified Group A subgroups Device type Limits Unit Min Max Output response to step transient load changes 6/ VOTLOAD500 mA to/from 1000 mA 4 01 -300 +300 mV pk 5,6-450 +4500 mA to/from 500 mA 4 -500 +500 5,6-750 +750Re

39、covery time, step transient load changes 6/ 7/ TTLOAD500 mA to/from 1000 mA 4,5,6 01 100 s 0 mA to 500 mA 1500 500 mA to 0 mA 10 ms Output response transient step line changes VOTLINEInput step 16 V to/from 40 V dc, IOUT= 1000 mA 4/ 8/ 4,5,6 01 1500 mV pk Recovery time transient step line changes TT

40、LINEInput step 16 V to/from 40 V dc, IOUT= 1000 mA 4/ 7/ 8/ 4,5,6 01 800 s Turn on overshoot VtonOSIOUT= 0 and 1000 mA 4,5,6 01 600 mV pk Turn on delay TonDIOUT= 0 and 1000 mA 9/ 4,5,6 01 20 ms Load fault recovery 4/ TrLF4,5,6 01 20 ms 1/ Parameter guaranteed by line and load regulation tests. 2/ Ba

41、ndwidth guaranteed by design. Tested for 20 Hz to 2 MHz. 3/ Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detect

42、ion circuitry, appearing as a short circuit during turn-on. 4/ Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be guaranteed to the limits specified in table 1. 5/ An overload is that condition with a load in excess of th

43、e rated load but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation. 6/ Load step transition time between 2 and 10 microseconds. 7/ Recovery time is measured from the initiation of the transient to where VOUThas returned to within 1 per

44、cent of VOUTat 50 percent load. 8/ Input step transition time between 2 and 10 microseconds. 9/ Turn-on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the inhibit pin (pin 1) while power is applied to the input. Provided by IHSNot

45、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94568 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 7 DSCC FORM 2234 APR 97 Case outline X. Symbol Millimeters InchesMin Max Min MaxA 8.38 .330B 0.64 0.8

46、9 .025 .035D 36.70 36.96 1.445 1.455 eA 20.19 20.45 .795 .805e1 12.70 12.95 .500 .510e2 17.78 18.03 .700 .710e3 22.86 23.11 .900 .910e4 27.94 28.19 1.100 1.110 E 28.32 28.58 1.115 1.125 L 6.35 6.86 .250 .270R1 2.03 2.54 .080 .100S 5.08 5.33 .200 .210NOTES: 1. The U.S. government preferred system of

47、measurement is the metric SI. This item was designed using inch-pound units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound units shall rule. 2. Case outline X weight: 30 grams maximum. FIGURE 1. Case outlines. Provided by IHSNot for Re

48、saleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94568 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 8 DSCC FORM 2234 APR 97 Case outline Z. Symbol Millimeters Inches Min Max Min Max A 8.38 .330 B 0.64 0.89 .025 .035 B1 2.51 2.77 .099 .109 D 36.70 36.96 1.445 1.455 D1 48.01 48.51 1.890 1.910 D2 42.93 43.43 1.690 1.710 e1 7.37 7.8