1、-_I_ - - A-A-54759 m 9999974 0103930 514 I INCH-POUND 1 A-A-5 4 7 5 9 15 October 1992 COMMERCIAL ITEM DESCRIPTION CANISTER AND TIMER SYSTEM (Oropharyngeal Suction Apparatus) The General Services Administration has authorized the use of this Commercial Item Description. This Commercial Item Descripti

2、on covers a system of 3 canisters connected to a manifold and an electrical timer to convert a 115 volt suction apparatus from constant flow to intermittent flow. Salient characteristics: The unit shall be a three-canister and timer system ,for Wangensteen type intermittent suctioning of 3 patients

3、simultaneously providing an on-off timer for intermittent interruption of power supply to a suction apparatus. shall be suitable for use in hospital and military aeromedical aircraft. it The system shall include the following: least 6 feet long to connect the systems manifold to a suction apparatus.

4、 a. A vacuum supply hose (tubing), 3/8 inch ID by at b. with a range from O to 760 mm Hg vacuum, connected to the manif old. A vacuum gauge, with connector for the supply hose, c. A manifold to receive vacuum from a suction apparatus and feed adjustable vacuum to 3 suction canisters. d. Three vacuum

5、 adjustment valves, mounted on the manifold, each with a fitting for connection of the canisters vacuum lines. AMSC N/A FSC 6515 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from

6、 IHS-,-,-_ A-A-54759 9999974 OL0393L 450 A-A-54 7 59 e. Three vacuum lines, 1/4 inch ID by at least 6 feet long, for connection between the manifolds adjustable vacuum valves and 3 canisters. f. Three disposable suction canisters, each with working capacity of at least 1200 cc having graduation mark

7、ings conforming with ANSI 279.9 and having a barb or tapered connector for 1/4 patient tubing. g. An electrical control box to provide ON-OFF cycling of 115 volt, 50 to 400 Hz power source to a suction apparatus. The control box, with its power cord assembly, shall be designed to control Electromagn

8、etic Interference (EMI) and Radio Frequency Interference (RFI). The control box shall include: 1. A flush mounted 115 volt receptacle to receive a power cord with a hospital grade plug to provide cycled on-off power to a surgical suction apparatus (marked to identify as timed/cycled on-off power). 2

9、. A flush mounted 115 volt hospital grade receptacle for general purpose use (not time/cycled controlled). 3. A 115 volt cord with hospital grade plug, hard 4. A timer to intermittently interrupt power from wired, to allow input power from a wall receptacle. 115 VAC wall source providing power cycli

10、ng of 15 seconds off and 45 seconds on. The switch circuit shall be rated at least 5 amps. h. Three mounting bracket sets to mount each of the canisters on a stanchion with cross-section of either 2 inches by 2 inches or 2-3/4 inches by 2 inches. The system shall be compatible with the oropharyngeal

11、 suction apparatus described in Commercial Item Description A-A-54039. Workmanship. defects which detract from its appearance or impair its serviceability. The canister and timer system shall be free from Unit. Each (EA). One canister and timer system, as specified, constitutes one unit. 2 Provided

12、by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-_-I_- - A-A-54759 = 9999974 0303932 397 m A-A-54 7 5 9 Operational and Service Data Manuals shall be furnished as follows : a. information content: The contractor shall furnish manuals, handbooks, and/or brochur

13、es containing complete operation, installation and service/maintenance instructions (including pictures or illustrations, as necessary) with complete schematics and wiring diagrams (if unit has electric circuitry). All manuals, handbooks, and/or brochures shall be written in the English language and

14、 all schematics and wiring diagrams shall use American electrical data and connection diagrams for all I applicable utilities. The instructions shall also contain a complete list of all replaceable parts showing part number, name and quantity required. All service notes, service memo, etc., pertaini

15、ng to the equipment and issued subsequent to the printing of the original instructions shall also be included. These instructions shall be, as a minimum, that furnished to service engineers (or servicemen) that normally install and service the equipment for the company or distributor. procured inclu

16、des, or will operate ancillary equipment, the service data shall include complete instructions and drawings which show interfacing of all system components. When the system being b. Quantities: Two (2) complete sets of the above information shall be packaged with each unit of the required equipment.

17、 Quality Assurance Provisions. Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract or purchase order, the contr

18、actor may use his own or any facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary t

19、o assure supplies and services conform to prescribed requirements. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- A-A-54759 9999974 0303933 223 = A-A- 5 4 7 5 9 Records. Records of examinations and tests performed by or for the contractor shall b

20、e maintained by the contractor and made available to the Government upon the Governments request, at any time, or from time to time, during the performance of the contract and for a period of three years after delivery of the supplies to which such records relate. Inspection. Inspection, as used her

21、ein, is defined as both examination (such as visual or auditory investigation without the use of special laboratory appliances or procedures) and testing (determination by technical means of physical and chemical properties) of the item. Samplinq for examination. Sampling for examination shall be co

22、nducted in accordance with MIL-STD-105, with an AQL of 1.0 (percent defective) and an inspection level of I. The unit of product for examination purposes shall be one canister and timer system, as specified. Samplinq for tests. Sampling for tests, including dimensional test, shall be conducted in ac

23、cordance with MIL-STD-105, with an AQL of 1.0 (percent defective) and an inspection level of I. The unit of product for test purposes shall be one canister and timer system, as specified. Tests. Tests shall be conducted to determine compliance with specification requirements. Where feasible, the sam

24、e sample shall be used for the determination of two or more test characteristics. Metric products. Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units, providing they fall within the tolerances specified using conversion tabl

25、es contained in the latest revision of Federal Standard 376, and all other requirements of this document are met. If a product is manufactured to metric dimensions and those dimensions exceed the tolerances specified in the inch/pound units, a request should be made to the contracting officer to det

26、ermine if the product is acceptable. i e: The contracting officer has the option of accepting or rejecting the product. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3 t I_-I_- - A-A-54759 = 9999974 0303934 3bT A-A-54 7 5 9 Contractor certificati

27、on. The contractor shall certify and maintain substantiating evidence that the product offered meets the salient characteristics of this Commercial Item Description, and that the product conforms to the producers own drawings, specifications, standards, and quality assurance practices. The governmen

28、t reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract. Requlatorv requirements. Federal Food, Druq and Cosmetic Act. If the product covered by this document has been determined by the U.S

29、. Food and Drug Administration to be under its jurisdiction, the offeror/contractor shall comply, and be responsible for compliance by its subcontractors/suppliers, with the requirements of the Federal Food, Drug and Cosmetic Act, as amended, and regulations promulgated thereunder. In addition, the

30、offeror/contractor shall comply, and be responsible for compliance by its subcontractors/suppliers, with the requirements of all other applicable Federal, State, and local statutes, ordinances, and regulations. Recovered materials. The offeror/contractor is encouraged to 0 use recovered material in

31、accordance with Federal Acquisition Regulation Subpart 23.4 to the maximum extent practical. Preservation, packaqinq, p ackinq, labelins, and markinq. Unless otherwise specified, preservation, packaging, and packing shall be to a degree of protection to preclude damage to containers and/or contents

32、thereof under normal shipping conditions, handling, etc:, involving shipment from the supply source to the receiving activity, plus reshipment from receiving activity, and shall conform to applicable carriers rules and regulations. Intermediate and exterior package quantities and labeling and markin

33、g shall be as specified in the contract and/or order. Orderinq data. Intermediate/exterior package quantities, labeling, and marking must be specified in the contract and/or order. NOTE: The following National Stock Number is covered by this document. 6515-01-356-4830 5 Provided by IHSNot for Resale

34、No reproduction or networking permitted without license from IHS-,-,- A-A-54759 = 9999974 0303935 OTb A-A-5 4 7 5 9 MILITARY INTERESTS: PREPARING ACTIVITY: Custodians: DoD-MB Air Force - 03 Army - MD Navy - MS Agent : DLA-DM CIVIL AGENCY COORDINATING ACTIVITIES: FDA-MPQAS VA - OSS USPHS Project Number: 6515-5458 Location: TIMER12C.DOC 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-