ECA 186-2E-1978 Passive Electronic Component Parts Test Methods for Method 2 Moisture Resistance (Cycling).pdf

上传人:吴艺期 文档编号:703928 上传时间:2019-01-03 格式:PDF 页数:5 大小:256.05KB
下载 相关 举报
ECA 186-2E-1978 Passive Electronic Component Parts Test Methods for Method 2 Moisture Resistance (Cycling).pdf_第1页
第1页 / 共5页
ECA 186-2E-1978 Passive Electronic Component Parts Test Methods for Method 2 Moisture Resistance (Cycling).pdf_第2页
第2页 / 共5页
ECA 186-2E-1978 Passive Electronic Component Parts Test Methods for Method 2 Moisture Resistance (Cycling).pdf_第3页
第3页 / 共5页
ECA 186-2E-1978 Passive Electronic Component Parts Test Methods for Method 2 Moisture Resistance (Cycling).pdf_第4页
第4页 / 共5页
ECA 186-2E-1978 Passive Electronic Component Parts Test Methods for Method 2 Moisture Resistance (Cycling).pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、f EIA 18b-2E 78 W 3234b00 0028582 L W -. .- L, 3 a w a I ANSI/EIA RS-186-E-78 Approved October 27,1978 EIA STANDARD I (o 00 VI a STANDARD TEST METHODS FOR PASSIVE ELECTRONIC COMPONENT BARTS i RSm186.2E EIA 186-2E 78 m 3234600 0028586 9 m RS-186-2E Page 3 e 2.6 2.7 3, 3.1 3.2 3.3 3.4 3.5 3.6 Controll

2、ed Conditions - In order to insure the temperature and humidity are controlled within the Emits of the specification the instrumentation accuracy should be I1“C on temperature and 41% RH on moisture. The water utilized to produce the atmosphere should be conditioned bj an agpropriate method to assur

3、e consistently pure water with a pH value between 6.0 and 7.2 at 23 C (73 P). Final Measurements (to be taken per Paragraph 2.7.1 unless otherwise specified). 2.7.1 2.7.2 2.7.3 After Humidity - After the final cycle measurements shall be made within a period of 1 to 2 hours after removal from the hu

4、midity chamber. During the final measurements, the specimens shall not be subjected to any means of artificial drying. At High Humidity - If measurements at high humidity are specified in the individual specifica- tion, upon completion of Step 6 (Figure 1) of the final cycle, the specimens shall be

5、maintained at a temperature of 25 +2“C(77 k3.6“F) and a relative humidity of 90 to 95% for a period of 1% to 3% hours, after which the measurements specified shall be made in the chamber. After Drying-Period - If measurements after a drying period are specified then following Step 6 of the final cyc

6、le the specimens shall be conditioned at a temperature of 25 +2“C(77 k3.6“F) and a relative humidity of 50 +5% for a period of twenty-four hours, after which the measure- ments specified in the individual specification shall be made. SUMMARY The following details shall be specified in the individual

7、 specification: Mounting, if additional mounting requirements are necessary. Initial measurements (2.2). Polarization and load. 3.3.1 3.3.2 Exposure duration, number of cycles (2.5) if other than 10 cycles. Details of any low-temperature or vibration subcycling, if applicable (2.3). Final measurements (2.7). Magnitude and points of application of polarizing voltage, if applicable (2.4). Magnitude of loading voltage, if applicable (2.4).

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1