1、. EIA 520DAAC 90 3234600 0073507 3 M o a a ta O Cu v) I w 0 ANSI/ EIA-520DAAC-19 O O APPROVED: May 18, 1990 SPECIFICATION l Detail Specification on 4 Pole Toggle Switches EIA-520DAAC JUNE 1990 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT The NECQ System EIA 520DAAC 90 3234600 0073508 5 =

2、 I NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum

3、delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publ

4、ications preclude their voluntary use by those other than EIA members, whether the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials, or p

5、rocesses. By such action, EIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Recommended Standard or Publication. This EIA Specification is considered to have International Standardization implication, but the International Elect

6、rotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Specification and the IEC document can be made. This Specification does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the res

7、ponsibility of the user of this Specification to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From EIA Standards Proposal No. 2195 formulated under the cognizance of the EIA P- 13.2 Subcommittee on Toggle, Rocker, Pad

8、dle O nt.0 o51-j p- STEEL 4 II - _ FED STD NO. 66, 55, O00 PSI (MIN SULPHLTR OR PHOSPHORUS: SHALL NOT EXCEED 0.05 BY WEIGHT) hl A TE RIAL FINISH CADMIUM PLATE QQ - P 4 MIL HARDWARE CAN BE REPLACED BY MS35206-241 ( -164-32) 6 .fOf0.20 #-3 ( .2 6 32.0 07) kES t0.00 (“?O3 I 635-0.80 +OOO) MATERIAL FED

9、STD NO. 66 FINISH PASSIVATE MS51957-26 ( .138-32) hlIL HARDWARE CAN BE REPLACED BY hls51957-41 (. 164-32)- J I THREAD S RIA TER IA L I MIL HARDWARE EU-520DAAC Page I1 QQ-S- 700 CADMIUM PLATE QQ-P-416, TYPE II, CLASS 3 CAN BE REPLACED BY MS35338-41 ( .138) Rls35338-42 (.164) ZE 1 CRES 1 /-38-32UNC- 2

10、 A MA TE RIAL FED STD NO. 66 MIL HARDWARE CAN BE REPLACED BY - 1:; . FINISH PASSIVATED - BRONZE MA TER IA L QQ-B750, COMPOSITION A, HARD FINISH CADRIIUM PLATE QQ-P-416, TYPE II, CLASS 3 MS35338-98 ( ,138) RIIL HARDWARE CAN BE REPLACED BY R.Is35338-99 (. 164) FIGURE 8 - PAN HEAD SCREW DIIIE#SIOIQS .0

11、 *.IS4 (.O 3 4+D O 3) PIGRE 9 - SPLIT BIHG WCKWASHER DIP!EMSIOHS EIA 520DAAC 90 3234600 0073520 b EIA-520DAAC Page 12 1.9 Ratings and Characteristics 1.9.1 Ratings Al titude Electrical - power - logic level - low level Flammability Fluid resistance Fungus resistance Icing Moisture resistance Random

12、vibration Salt Spray Sand and Dust Sealing Shock Temperature Thermal Shock Vibration 1.9.2 Characteristics Actuator grounding Altitude voltage proof see note 11 Capacitance Contact bounce EM1 shielding Endurance - electrical (at high temp. - logic level - low level - mechanical and at 65,000 ft) Exp

13、losion Immersion in cleaning solvents Insulation resistance Mass including mounting hardware Operating characteristics - Total travel - Operating force Overload Resistance to soldering heat Solderability Strength of - actuator - mounting bushing - termination - IWTS - screw - solder 65,000 ft See Ta

14、ble PI not applicable not applicable applicable not applicable applicable not applicable applicable not applicable 96 hours applicable watertight immersion 75 G, half-sine -55C to 70C -55C to 125C 10 G, 10-500 HZ not applicable 500 Vrms not applicable not applicable not applicable 20,000 cycles with

15、 no sticks or misses not applicable not applicable 40,000 cycles applicable. See clause 1.10.1. not applicable not applicable 0.23 pound maximum See Figure 1 not applicable applicable applicable to solder terminals only applicable to solder terminals only 25 pounds 15 pound-inches 15 lb for 5-10 s 5

16、 pound-inches 5 pound EIA 520DAAC 90 m 3234600 0073521 8 m 28 Vdc resistive inductive lamp load EIA-520DAAC Page 13 115 Vac, 60 & 400 Hz resistive inductive lamp load Switch “resistance not applicable Temperature rise - at 6,000 cycles 30C maximum - at 20,000 cycles 50C maximum Voltage proof see not

17、e 11 1500 Vac NOTE I: After electrical endurance testing, the points of application of the test voltage shall be from terminals to ground only. 1.10 Increased severities or requirements which are additional to those specified in the generic and/or sectional specification 1.10.1 Explosion Object: The

18、 objective of the test is to assess whether a switch, while operating, will ignite an ambient explosive atmosphere prevalent in aircraft applications. This test is not necessary for switches which are enclosed in housings (casings) designed to prevent flame or explosion propagation. Test Method: Swi

19、tches shall be tested in accordance with Method 109 of MIL-STD-202. Switches shall be operated at their maximum rated dc inductive current at the rated voltage. Criteria: The explosive mixture in the test chamber surrounding and external to the switch shall not explode whether or not an explosion oc

20、curs within the switch. Switches shall be electrically operable after the test. TABLE II - ELECTRICAL RATING CODES CODE 1 2 I current capacity (amperes) 20 18 5 4 I 8 4 2 - EIA 520DAAC 90 m 3234b00 0073522 T EIA-5 20DAAC Page 14 SECTION TWO - INSPECTION REQUIREMEFITS Q 2. Inspection Requirements 2.1

21、 Qualification Approval inspection requirements shall be in accordance with Table III for multiple product approvals. 2.2 Quality Conformance Inspection requirements are prescribed in Table IV for lot-by-lot inspections and Table VI for periodic inspections. For visual examination, the clarification

22、 of major and minor defects shall be in accordance with Table V. TABLE III - QUALIFICATION TEST FOR MULTIPLE PRODUCT APPROVAL Test Method &. Test Group GROUP A (non-destructive) Visual examination Dimensions Mass Functional operation Operating characteristics Voltage proof GROUP B (destructive) Sold

23、erability Strength of terminations Strength of actuator Overload Elect. endurance-high temp. Elect. endurance-altitude Temperature rise Voltage proof Operating characteristics Sealing-watertight immersion Group C (destructive) Thermal shock Vibration Shock Moisture resistance Operating characteristi

24、cs . Voltage proof Sealing-watertight immersion Test NO. 1-1 1-2 1-4 1-5 1-6 3-1 11-1 6-4 6-1 9-1 8-2 8-3 4-1 3-1 1-6 14-1 10-2 5-3 5-2 10-1 1-6 3-1 14-1 Test Samples all units ll i11 all units all units all units 4 units having solder 4 units of each terminal 4 units of each toggle terminals style

25、lever style 21 21 21 all units from Test 8-2 all Group B samples all Group B samples all Group B samples 4 units each of O1 and 07 switching circuits 4 units each of O1 and 07 switching circuits 4 units each of O1 and 07 switching circuits 4 units each terminal style all Group C samples all Group C

26、samples all Group C samples t.d O O O O O O O O O O O O O O O O O O O O O O O 3.d O O 4 O e O 11-1 i 1-5 EIA 520DAAC 90 = 3234600 0073523 L EIA-520DAAC Page 15 TABLE III (conte) “ QUALIPICATIOLJ TEST POR MULTIPLE PRODUCT APPROVAL Test Method & Test Group GROUP D (destructive) Strength of mtg. bushin

27、g Operating characteristics Voltage proof GROUP E (destructive) Mechanical endurance Operating characteristics Sealing-watertight immersion GROUP F (destructive) Salt Spray GROUP J (destructive) Flammability GROUP K (destructive) Explosion Test NO. 6-2 1-6 3-1 7-1 1-6 14-1 10-4 16-1 clause 1.10 1 Te

28、st Samples 4 units of any type designation all Group D samples all Group D samples 4 units each of O1 and 07 switching circuits all Group E samples all Group E samples 2 units of each terminal style i31 2 units of electrical rating code 1 KEY: t.d. = maximum permissible number of defective units per

29、 test g,d. = maximum permissible number of defective units per test group. NOTES: 111 I21 131 t.d. O O O O O O O O O O O O 3.d. O O O 2 units each of each terminal configuration and each toggle lever style. 2 units each of switching circuits O1 and 07 for each electrical load, Test samples shall be

30、in accordance with ANSI/UL 94. TABLE IV - LOT-BY-LT IISPBCTIO TESTS TEST METHOD & TEST GROUP GROUP A (lot-by-lot) Visual examination Major Minor Functional operation Voltage proof operating characteristics TEST NO “D“ or 7 II i ND ND I 11 _.:i 1.0 1.0 EIA 520DAAC 30 3234600 0073524 3 = EIA-520DAAC P

31、age 16 TABLE V - MAJOB CHARACTERISTICS POR VISUAL EXAMIATIO Characteristic properly assembled physical damage keyway location properly marked proper lever assembly proper locking arrangement smooth, even terminal plating gauge check of terminals standard toggle lever lever-lock toggle lever X X X X

32、X X screw terminal X X X X TABLE VI - PERIODIC ISPECTIOS Test Method & Test Group GROUP X (every 12 months) Dimensions Mass Solderability Electrical endurance at altitude 111 Temperature rise Voltage proof Operating characteristics Sealing-watertight immersion GROUP Y (every 36 months) Thermal shock

33、 Vibration Shock Moisture Operating characteristic Voltage proof Sealing-watertight immersion Test NO. 1-2 1-4 11-1 0-13 4-1 3-1 1-6 14-1 10-2 5-3 5-2 10-1 1-6 3-1 14-1 solder terminal Test Samples 2 units of EIA520DAAC-07X2 11 11 II Il Il Il 11 Il 11 11 Il 11 11 Il 4 units of EIA520DAAC-OlX3 11 Il

34、Il Il W Il 11 11 Il 11 Il 11 IWTS X X X X X - t.d. O O O g.d. O NOTES I - Electrical load shall be 28 Vdc, 10 amperes inductive load. t.d. = maximum Permissible number of defective units per test. g.d. = maximum permissible number of defective units per group. EIA 520DAAC 90 m 3234600 0073525 5 m r

35、EIA STANDARD AND SPECIFICATION NUMBERING STAN DARD A document that establishes engineering and technical requirements for processes, procedures, practices and methods that have been decreed by authority or adopted by consensus. Standards may also be established for selection, application and design

36、criteria for material. i Standards and other documents not in the specification format use only the EIA basic numbering system as follows: EIA-123 Original Standard EIA-123-1 Addendum to Original Standard EIA-123-A First Revision of original Standard incorporating all Addenda SPECIFICATION A documen

37、t prepared specifically to facilitate procurement which clearly and accurately describes the essential technical requirements for purchased material. . Procedures necessary to determine that the requirements for the purchased material covered by the specification have been met shall also be referenc

38、ed or included. EIA Specifications use the following system: E/A 1 i 3 Standard Prefix for ail Numbers Standard or Generic Specification Sectional Specification Designator Blank Detail Specification Designator I Detail Specification Designator A I EIA I230000 EIA 123A000 EIA 123AAOO EIA 123W EIA 123

39、OOAA is a Generic Specification is a Sectional Specification is a Blank Detail Specification is a Detail Specification is a Detail Specification for which no Sectional or Blank Detail Specification was issued. NOTES: 1. Some older specifications may not have been converted to this numbering system. 2. See EP-11 “Guide for the Preparation of Specification Using IECQ-System Format,“ for more detail.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1