1、 EIA STANDARD Fixed Capacitors for Use in Electronic Equipment - Part 24: Sectional Specification - Fixed Tantalum Electrolytic Surface Mount Capacitors with Conductive Polymer Solid Electrolyte EIA-60384-24 (IEC 60384-24:2015, IDT) June 2017 Electronic Components Industry Association ANSI/EIA-60384
2、-24-2017 Approved: June 30, 2017 EIA-60384-24 NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchas
3、er in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor sh
4、all the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (
5、ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is identical (IDT) with the International Standard IEC Publication 60384-24:2015 Edition 2: Fixed
6、 Capacitors for Use in Electronic Equipment - Part 24: Sectional Specification - Fixed Tantalum Electrolytic Surface Mount Capacitors with Conductive Polymer Solid Electrolyte. This document is the EIA Standard EIA-60384-24-2017 Edition 2: Fixed Capacitors for Use in Electronic Equipment - Part 24:
7、Sectional Specification - Fixed Tantalum Electrolytic Surface Mount Capacitors with Conductive Polymer Solid Electrolyte. The text, figures and tables of IEC 60384-24:2015 are used in this Standard with the consent of the IEC and the American National Standards Institute (ANSI). The IEC copyrighted
8、material has been reproduced with permission from ANSI. The IEC Foreword and Introduction are not part of the requirements of this standard but are included for information purposes only. This Standard does not purport to address all safety problems associated with its use or all applicable regulato
9、ry requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5355, formulated under the cognizance of the Steering Committee for Pa
10、ssive Electronic Components Standards (S-1). Published by Electronic Components Industry Association 2017 Engineering Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE ! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Orga
11、nizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: IHS Markit 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5186), International (303-397-7956) i CONTENTS FOREWORD . iv 1 Gene
12、ral 1 1.1 Scope 1 1.2 Object 1 1.3 Normative references . 1 1.4 Information to be given in a detail specification 1 1.4.1 General . 1 1.4.2 Outline drawing and dimensions . 2 1.4.3 Mounting . 2 1.4.4 Ratings and characteristics 2 1.4.5 Marking . 3 1.5 Terms and definitions . 3 1.6 Marking 3 1.6.1 Ge
13、neral . 3 1.6.2 Information for marking 3 1.6.3 Marking on capacitors 3 1.6.4 Marking on packaging 3 2 Preferred ratings and characteristics 3 2.1 Preferred characteristics . 3 2.2 Preferred values of ratings 4 2.2.1 Nominal capacitance (CN) 4 2.2.2 Tolerance on nominal capacitance . 4 2.2.3 Rated v
14、oltage (UR) 4 2.2.4 Category voltage (UC) . 4 2.2.5 Surge voltage (URSor UCS) 4 2.2.6 Rated temperature . 4 3 Quality assessment procedures . 5 3.1 Primary stage of manufacture . 5 3.2 Structurally similar components . 5 3.3 Certified test records of released lots 5 3.4 Qualification approval proced
15、ures . 5 3.4.1 General . 5 3.4.2 Qualification approval on the basis of the fixed sample size procedure . 5 3.4.3 Tests 6 3.5 Quality conformance inspections 13 3.5.1 Formation of inspection lots 13 3.5.2 Test schedule . 14 3.5.3 Delayed delivery . 14 3.5.4 Assessment levels 14 4 Test and measuremen
16、t procedures . 15 4.1 Preliminary drying . 15 4.2 Measuring conditions . 15 4.3 Mounting . 15 4.4 Visual examination and check of dimensions. 15 ii 4.4.1 General 15 4.4.2 Visual examination and check of dimensions 15 4.4.3 Requirements . 15 4.5 Electrical tests . 16 4.5.1 Leakage current . 16 4.5.2
17、Capacitance . 16 4.5.3 Tangent of loss angle (tan ) . 16 4.5.4 Equivalent series resistance (if required) . 17 4.6 Resistance to soldering heat 17 4.6.1 General 17 4.6.2 Initial inspections 17 4.6.3 Test conditions . 17 4.6.4 Recovery . 17 4.6.5 Final inspections and requirements . 17 4.7 Solderabil
18、ity 17 4.7.1 General 17 4.7.2 Final inspections and requirements . 17 4.8 Shear test . 17 4.9 Substrate bending test (if required) 18 4.9.1 General 18 4.9.2 Initial inspections 18 4.9.3 Test conditions . 18 4.9.4 Final inspections and requirements . 18 4.10 Rapid change of temperature . 18 4.10.1 Ge
19、neral 18 4.10.2 Initial inspections 18 4.10.3 Test conditions . 18 4.10.4 Recovery . 18 4.10.5 Final inspections and requirements . 18 4.11 Climatic sequence . 18 4.11.1 General 18 4.11.2 Initial inspections 18 4.11.3 Dry heat . 19 4.11.4 Damp heat, cyclic, test Db, first cycle 19 4.11.5 Cold . 19 4
20、.11.6 Damp heat, cyclic, test Db, remaining cycles . 19 4.11.7 Recovery . 19 4.11.8 Final inspections and requirements . 19 4.12 Damp heat, steady state 19 4.12.1 General 19 4.12.2 Initial inspections 19 4.12.3 Test conditions . 19 4.12.4 Recovery . 19 4.12.5 Final inspections and requirements . 19
21、4.13 Characteristics at high and low temperature 20 4.13.1 General 20 4.13.2 Initial inspections and requirements . 20 4.14 Surge voltage 20 iii 4.14.1 General 20 4.14.2 Initial inspections 20 4.14.3 Test conditions . 20 4.14.4 Recovery . 20 4.14.5 Final inspections and requirements . 20 4.15 Endura
22、nce 20 4.15.1 General 20 4.15.2 Initial inspections 21 4.15.3 Test conditions . 21 4.15.4 Recovery . 21 4.15.5 Final inspections and requirements . 21 4.16 Component solvent resistance (if required) . 21 4.17 Solvent resistance of marking (if required) 21 4.18 High surge current (if required) 21 4.1
23、9 Storage at high temperature . 21 4.19.1 General 21 4.19.2 Initial inspections 21 4.19.3 Test conditions . 21 4.19.4 Recovery . 21 4.19.5 Final inspections and requirements . 22 Bibliography . 23 Table 1 Category and surge voltages . 5 Table 2 Category and surge voltages . 5 Table 3 Sampling plan f
24、or qualification approval, assessment level EZ 7 Table 4 Test schedule for qualification approval (1 of 6) 8 Table 5 Lot-by-lot inspection . 14 Table 6 Periodic inspection . 15 iv INTERNATIONAL ELECTROTECHNICAL COMMISSION _ FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT Part 24: Sectional specific
25、ation Fixed tantalum electrolytic surface mount capacitors with conductive polymer solid electrolyte FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The obje
26、ct of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specificatio
27、ns (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaisi
28、ng with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express,
29、 as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees
30、 in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Co
31、mmittees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not pr
32、ovide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the l
33、atest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, w
34、hether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
35、 indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC
36、60384-24 has been prepared by IEC technical committee 40: Capacitors and resistors for electronic equipment. This second edition cancels and replaces the first edition published in 2006 and constitutes a technical revision. This edition includes the following significant technical changes with respe
37、ct to the previous edition: Revision of the structure in accordance with ISO/IEC Directives, Part 2:2011 (sixth edition) to the extent practicable, and harmonization between other similar kinds of documents. In addition, Clause 0 and all the tables have been reviewed in order to prevent duplications
38、 and contradictions. v The text of this standard is based on the following documents: FDIS Report on voting 40/2382/FDIS 40/2395/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted i
39、n accordance with the ISO/IEC Directives, Part 2. The list of all parts of the IEC 60384 series, under the general title Fixed capacitors for use in electronic equipment, can be found on the IEC website. The committee has decided that the contents of this publication will remain unchanged until the
40、stability date indicated on the IEC website under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended.EIA-60384-24 Page 1 FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT Part
41、 24: Sectional specification Fixed tantalum electrolytic surface mount capacitors with conductive polymer solid electrolyte 1 General 1.1 Scope This part of IEC 60384 applies to fixed tantalum electrolytic surface mount capacitors with conductive polymer solid electrolyte primarily intended for d.c.
42、 applications for use in electronic equipment. Fixed tantalum electrolytic surface mount capacitors with solid (MnO2) electrolyte are not included but are covered by IEC 60384-3. These capacitors are primarily intended for use in electronic equipment to be mounted directly on substrates for hybrid c
43、ircuits or to printed boards. Capacitors for special-purpose applications may need additional requirements. 1.2 Object The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring m
44、ethods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification shall be of equal or higher performance level, because lower performance levels are not permitted. 1.3 Normat
45、ive references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) a
46、pplies. IEC 60063, Preferred number series for resistors and capacitors IEC 60068-1:2013, Environmental testing Part 1: General and guidance IEC 60384-1:2008, Fixed capacitors for use in electronic equipment Part 1: Generic specification IEC 61193-2:2007, Quality assessment systems Part 2: Selection
47、 and use of sampling plans for inspection of electronic components and packages ISO 3, Preferred numbers Series of preferred numbers 1.4 Information to be given in a detail specification 1.4.1 General Detail specifications shall be derived from the blank detail specification. EIA-60384-24 Page 2 Det
48、ail specifications shall not specify requirements inferior to those of the generic, sectional or blank detail specification. When more severe requirements are included, they shall be listed in 1.9 of the detail specification and indicated in the test schedules, for example, by an asterisk. The infor
49、mation given in 0 may, for convenience, be presented in tabular form. The following information shall be given in each detail specification and the values quoted shall preferably be selected from those given in the appropriate clause of this sectional specification. 1.4.2 Outline drawing and dimensions There shall be an illustration of the capacitors as an aid to easy recognition and for comparison of the capacitors with others. Dimensions and their associated tolerances, which affect interchangeability and mounting, shall be given in the detail spec