EN 1067-2005 en Adhesives - Examination and preparation of samples for testing《粘胶剂 测试样品的检验和准备》.pdf

上传人:priceawful190 文档编号:705502 上传时间:2019-01-03 格式:PDF 页数:12 大小:286.98KB
下载 相关 举报
EN 1067-2005 en Adhesives - Examination and preparation of samples for testing《粘胶剂 测试样品的检验和准备》.pdf_第1页
第1页 / 共12页
EN 1067-2005 en Adhesives - Examination and preparation of samples for testing《粘胶剂 测试样品的检验和准备》.pdf_第2页
第2页 / 共12页
EN 1067-2005 en Adhesives - Examination and preparation of samples for testing《粘胶剂 测试样品的检验和准备》.pdf_第3页
第3页 / 共12页
EN 1067-2005 en Adhesives - Examination and preparation of samples for testing《粘胶剂 测试样品的检验和准备》.pdf_第4页
第4页 / 共12页
EN 1067-2005 en Adhesives - Examination and preparation of samples for testing《粘胶剂 测试样品的检验和准备》.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN1067:2005Adhesives Examination and preparation of samples for testingThe European Standard EN 1067:2005 has the status of a British StandardICS 83.180g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g

2、40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 1067:2005This British Standard was published under the authority of the Standards Policy and Strategy Committee on 25 January 2006 BSI 25 January 2006ISBN 0 580 47726 6National forewordThis British Standard is the official

3、English language version of EN 1067:2005. It supersedes BS EN 1067:1998 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee PRI/52, Adhesives, which has the responsibility to: A list of organizations represented on this committee can be obtained on request

4、 to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electr

5、onic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to und

6、erstand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a

7、front cover, an inside front cover, the EN title page, pages 2 to 9 and a back cover.The BSI copyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 1067December

8、 2005ICS 83.180 Supersedes EN 1067:1997 English VersionAdhesives - Examination and preparation of samples for testingAdhsifs - Examen et prparations des chantillons pouressaisKlebstoffe - Untersuchung und Vorbereitung von Probenzur PrfungThis European Standard was approved by CEN on 21 November 2005

9、.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on ap

10、plication to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has

11、the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovaki

12、a,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reservedworldwide for CE

13、N national Members.Ref. No. EN 1067:2005: EEN 1067:2005 (E) 2 Contents Page Foreword 3 1 Scope .4 2 Normative references .4 3 Terms and definitions.4 4 Sample container 4 4.1 Condition of container4 4.2 Opening of container 4 5 Preliminary procedure for fluid products consisting of a single homogene

14、ous liquid phase or two liquid phases .5 5.1 Visual examination5 5.1.1 Ullage .5 5.1.2 Surface skin.5 5.1.3 Consistency.5 5.1.4 Separation of phases5 5.1.5 Visible impurities 5 5.1.6 Sediment5 5.1.7 Clarity.5 5.1.8 Odour .5 5.2 Mixing 5 6 Preliminary procedure for fluid products consisting of one or

15、 two liquid phases together with one or more solid phases 6 6.1 Visual examination6 6.1.1 Ullage .6 6.1.2 Surface skin.6 6.1.3 Consistency.6 6.1.4 Separation of phases6 6.1.5 Settling.6 6.1.6 Extraneous matter.6 6.1.7 Odour .6 6.2 Mixing 6 6.2.1 Limitations.6 6.2.2 General 7 6.2.3 Removal of skin 7

16、6.2.4 No occurrence of hard settling 7 6.2.5 Occurrence of hard settling .7 7 Preliminary procedure for viscous products7 8 Preliminary procedure for products in powder form .7 9 Preliminary procedure for solid products not in powder form .8 10 Blending and reduction of a series of samples 8 10.1 Ge

17、neral 8 10.2 Fluid products (of type A, B or C)8 10.3 Viscous products (of type D) .8 10.4 Products in powder form (of type E) .8 10.5 Solid products not in powder form (type F)8 11 Labelling of sample containers8 12 Report of preliminary examination 9 EN 1067:2005 (E) 3 Foreword This European Stand

18、ard (EN 1067:2005) has been prepared by Technical Committee CEN/TC 193 “Adhesives”, the secretariat of which is held by AENOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2006, and confli

19、cting national standards shall be withdrawn at the latest by June 2006. This European Standard supersedes EN 1067:1997. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium,

20、Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 1067:2005 (E) 4 SAFETY STATEMENT: Persons u

21、sing this European Standard should be familiar with the normal laboratory practice, in principle. This European Standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices

22、and to ensure compliance with any regulatory conditions. 1 Scope This European Standard specifies both the procedure for preliminary examination of a single sample as received for testing, and the procedure for preparing a test sample by blending and reduction of a series of samples representative o

23、f a consignment or bulk of adhesives or related product. It is intended for use in conjunction with EN ISO 15605. 2 Normative references The following referenced documents are indispensable for the application of this European Standard. For dated references, only the edition cited applies. For undat

24、ed references, the latest edition of the referenced document (including any amendments) applies. EN 923, Adhesives Terms and definitions EN ISO 15605, Adhesives Sampling (ISO 15605:2000) ISO 565, Test sieves Metal wire cloth, perforated metal plate and electroformed sheet Nominal sizes of openings I

25、SO 8213, Chemical products for industrial use Sampling techniques Solid chemical products in the form of particles varying from powders to coarse lumps 3 Terms and definitions For the purposes of this European Standard, the definitions given in EN 923 apply. 4 Sample container 4.1 Condition of conta

26、iner Any defects in the sample container or any visible leakage shall be recorded. If it is possible that the contents have been affected, the sample shall be rejected unless it is being taken specifically to determine the extent to which the adhesive has been affected. 4.2 Opening of container Some

27、 adhesives and related products (such as primers) are prone to develop gas or vapour pressure during storage. Care, appropriate to the situation, shall be taken in opening the container, particularly if bulging of the lid or the bottom of the container is observed. If such phenomena occur, they shal

28、l be noted in the report of preliminary examination (see Clause 12 f). All packing materials (for example polystyrene chips, saw-dust) and other debris from the outer surface of the container shall be removed, particularly around the closure. The container shall be opened with care so as not to dist

29、urb the contents. EN 1067:2005 (E) 5 5 Preliminary procedure for fluid products consisting of a single homogeneous liquid phase or two liquid phases 1)5.1 Visual examination 5.1.1 Ullage Record the approximate ullage, i.e. the air-space above the contents of the container, expressed as a percentage

30、of the total capacity of the container. 5.1.2 Surface skin Record the presence of any surface skin and its type, i.e. whether continuous, whether hard or soft and whether thin or moderately or excessively thick. If any skin is present detach it as completely as possible from the sides of the contain

31、er and remove it, if necessary by sieving. Record the ease of removal. 5.1.3 Consistency Record whether the sample is thixotropic or whether gelling has taken place, taking care not to confuse gelling and thixotropy. NOTE Both thixotropic and gelled adhesives have a jelly-like consistency, but where

32、as the consistency of the former is markedly reduced by stirring or shaking, the consistency of a gelled adhesive cannot be reduced in this way. 5.1.4 Separation of phases Record any separation of the sample into layers, for example water and resinous matter. 5.1.5 Visible impurities If there are an

33、y visible impurities, record their presence and remove them if possible. 5.1.6 Sediment If there is any appreciable sediment, record its presence and appearance. 5.1.7 Clarity Record the clarity and colour of the sample. 5.1.8 Odour Record any odour detected. NOTE Care should be taken with regard to

34、 any resultant health hazards. Before handling the product the precautions indicated on its safety data sheet should be referred to. 5.2 Mixing Thoroughly stir the sample and incorporate any slight sediment. 1)These correspond to products of type A and B in EN ISO 15605.EN 1067:2005 (E) 6 6 Prelimin

35、ary procedure for fluid products consisting of one or two liquid phases together with one or more solid phases 2)6.1 Visual examination 6.1.1 Ullage Record the approximate ullage, i.e. the air-space above the contents of the container, expressed as a percentage of the total capacity of the container

36、. 6.1.2 Surface skin Record the presence of any surface skin and its type, i.e. whether continuous, whether hard or soft, and its approximate thickness. If any skin is present, detach it as completely as possible from the sides of the container and remove it, if necessary by sieving. Record the ease

37、 of removal. 6.1.3 Consistency Record whether the adhesive is thixotropic or whether gelling has taken place, taking care not to confuse gelling and thixotropy. NOTE Both thixotropic and gelled adhesives have a jelly-like consistency, but whereas the consistency of the former is markedly reduced by

38、stirring or shaking, the consistency of a gelled adhesive cannot be reduced in this way. 6.1.4 Separation of phases Record any separation of the samples into phases. 6.1.5 Settling Record the type of settling, for example soft, hard or hard-dry. If the settling is hard and appears dry and crumbly in

39、side a lump when cut with a clean palette knife, describe it as hard-dry. 6.1.6 Extraneous matter Remove any extraneous matter in the adhesive as carefully as possible and record its presence. 6.1.7 Odour Record any odour detected. NOTE Care should be taken with regard to any resultant health hazard

40、s. 6.2 Mixing 6.2.1 Limitations Samples which have gelled or show hard-dry settling (see 6.1.3 and 6.1.6) cannot be effectively made homogeneous and shall therefore not be used for testing purpose. 2)These correspond to products of type C in EN ISO 15605.EN 1067:2005 (E) 7 6.2.2 General During all t

41、he operations specified in 6.2.3 to 6.2.5 care shall be taken to ensure minimum loss of solvent. To this end, all the operations shall be carried out as rapidly as practicable and consistent with satisfactory mixing. 6.2.3 Removal of skin If the original sample contained skin, remove any remnants by

42、 straining the incorporated sample under its own weight, through a sieve conforming to ISO 565, of nominal aperture 125 m unless otherwise specified. 6.2.4 No occurrence of hard settling Mix the sample thoroughly, even if there is no perceptible settling. NOTE If the samples is less than 250 g a pal

43、ette knife is preferred as an alternative to the stouter stirrer normally used for larger samples. Firmly replace the lid of the container and thoroughly shake the contents, inverting the container as this is being done. Repeat the alternate stirring and shaking until the contents are completely hom

44、ogeneous. As an added precaution, it is recommended that the mixing be completed by pouring the contents into a clean container and back again several times. At all times during the sample preparation avoid, as far as possible, entrainment of air. The samples shall be free from air bubbles before us

45、e. 6.2.5 Occurrence of hard settling The examination of a sample in which hard settling has occurred (but not hard-dry settling, see 6.2.1) shall be completed in accordance with the procedure detailed below. Pour all the fluid medium into a clean container. Remove the settled pigment from the bottom

46、 of the container with a palette knife and mix thoroughly. When a uniform consistency has been achieved, return the medium to the original container, a small portion at a time, carefully incorporating each addition before the next is made. Complete the reincorporation by pouring from one container t

47、o the other several times (see 6.2.4). Ensure that the sample is free from air bubbles before use. 7 Preliminary procedure for viscous products3)Examine these products in general as for fluid products under Clause 6. NOTE Where mixing appears to be necessary to ensure homogeneity, a small, heavy-dut

48、y mixer can be used. 8 Preliminary procedure for products in powder form 4)No special procedure is normally required for these products. Unusual features such as abnormal colour, the presence of large or hard lumps, or the presence of foreign matters shall be recorded. 3)These correspond to products

49、 of type D in EN ISO 15605.4)These correspond to products of type E in EN ISO 15605.EN 1067:2005 (E) 8 9 Preliminary procedure for solid products not in powder form 5)No special procedure is normally required for these products. Unusual features such as abnormal colour, the presence of foreign matter shall be recorded. 10 Blending and reduction of a series of samples 10.1 General In cases where a series of samples have been taken from a homogeneous product, either test these separately, or combine them to produce a reduced sample as specified in 10.2 to 10.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1