1、BRITISH STANDARD BS EN 15102:2007Decorative wallcoverings Roll and panel form productsICS 91.180nullnull nullnullnullnullnullnullnull nullnullnullnullnullnullnull nullnullnull nullnullnullnullnullnullnullnullnullnull nullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnull nul
2、lnullnullnullnullnullnullnullnull nullnullnull+A1:2011National forewordThis British Standard is the UK implementation of EN 15102:2007+A1:2011. It supersedes BS EN 15102:2007, which is withdrawn.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags in
3、dicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1 is indicated by !“.The UK participation in its preparation was entrusted to Technical Committee CW/35, Wallcoverings.A list of organizations represented on this committee can be obtained
4、 on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 15102:2007+A1:2011This British Standard waspu
5、blished under the authorityof the Standards Policy andStrategy Committeeon 30 November 2007 BSI 2011ISBN 978 0 580 72595 1Amendments/corrigenda issued since publicationDate Comments30 November 2011 Implementation of CEN amendment A1:2011EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15102:2007
6、+A1 September 2011 ICS 91.180 Supersedes EN 15102:2007English Version Decorative wall coverings - Roll and panel form Revtements muraux dcoratifs - Rouleaux et panneaux Dekorative Wandbekleidungen - Rollen- und Plattenform This European Standard was approved by CEN on 23 September 2007 and includes
7、Amendment 1 approved by CEN on 4 August 2011. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concernin
8、g such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into it
9、s own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
10、Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-
11、1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15102:2007+A1:2011: EEN 15102:2007+A1:2011 (E) 2 Contents Page Foreword 41 Scope 52 Normative references 53 Terms and definitions .64 Characteristics .64.1 !Reactio
12、n to fire“ 64.2 Release of formaldehyde 74.3 !Release of other dangerous substances“ 74.3.1 Heavy metals and specific elements .74.3.2 Release of vinyl chloride monomer .94.4 Sound absorption 94.5 Thermal resistance 95 Evaluation of conformity .95.1 General 95.2 Initial type testing 95.2.1 General 9
13、5.2.2 Sampling, testing and compliance criteria 105.3 Factory production control (FPC) . 116 Marking and labelling . 11Annex A (normative) Factory production control . 12A.1 General . 12A.2 General requirements . 12A.3 Equipment . 13A.3.1 Testing . 13A.3.2 Manufacturing . 13A.4 Raw materials 13A.5 P
14、roduct testing and evaluation . 13A.6 Non-conforming products . 14A.7 Traceability 14A.8 !Initial inspection of factory and of FPC 14A.9 Continuous surveillance of FPC“ 15Annex B (normative) !Extended application rules within a group of product for the reaction to fire tests . 16B.1 Sampling 16B.2 P
15、roduct parameter having an influence on the products fire performance of wall coverings . 16B.3 End-use application parameters . 16B.4 Tests conducted according to EN 13823 intended for an extended application . 17B.4.1 Investigation of a group of product on different parameters . 17B.4.2 Usage of t
16、he test results obtained during the first step . 17B.5 Tests conducted according to EN ISO 11925-2 intended for an extended application . 17B.5.1 Investigation of a group of product on different parameters . 17B.5.2 Usage of the test results obtained during the first step“ 17Annex ZA (informative) R
17、elationship between this European Standard and the Essential Requirements of EU Directive 89/106/EEC, EU Construction Products Directive . 19ZA.1 Scope and relevant characteristics 19BS EN 15102:2007+A1:2011EN 15102:2007+A1:2011 (E) 3 ZA.2 Procedures for the attestation of conformity of wallcovering
18、 products in roll or panel form . 20ZA.2.1 Systems of attestation of conformity 20ZA.2.2 EC certificate of conformity and EC declaration of conformity 23ZA.3 CE marking and labelling 24ZA.3.1 General information for CE marking . 24ZA.3.2 Minimum CE marking information . 24ZA.3.3 Complete CE marking
19、information 25Bibliography 27BS EN 15102:2007+A1:2011EN 15102:2007+A1:2011 (E) 4 Foreword This document (EN 15102:2007+A1:2011) has been prepared by Technical Committee CEN/TC 99 “Wallcoverings”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a nationa
20、l standard, either by publication of an identical text or by endorsement, at the latest by March 2012, and conflicting national standards shall be withdrawn at the latest by June 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent right
21、s. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship
22、 with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This document includes Amendment 1, approved by CEN on 2011-08-04. This document supersedes EN 15102:2007. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! “
23、. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Irela
24、nd, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. BS EN 15102:2007+A1:2011EN 15102:2007+A1:2011 (E) 5 1 Scope This European Standard applies to all forms of wallcovering products in roll
25、 and panel form as defined in EN 235 supplied for hanging onto internal walls, partitions or ceilings, by means of an adhesive, whose primary purpose is decorative. However, certain wallcovering products may confer minor sound absorbtion and thermal resistance properties. It also provides for the ev
26、aluation of conformity of products to the requirements of this standard. It does not apply to wall coverings whose primary purpose is structural or protective (e.g. vapour or moisture barriers). 2 Normative references The following referenced documents are indispensable for the application of this d
27、ocument. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 71-3:1994, Safety of toys Part 3: Migration of certain elements EN 12149:1997, Wallcoverings in roll form Determination of migra
28、tion of heavy metals and certain other elements, of vinyl chloride monomer and of formaldehyde release EN 12524, Building materials and products Hygrothermal properties Tabulated design values EN 12667, Thermal performance of building materials and products Determination of thermal resistance by mea
29、ns of guarded hot plate and heat flow meter methods Products of high and medium thermal resistance EN 12781:2001, Wallcoverings Specification for cork panels EN 13085:2001, Wallcoverings Specification for cork rolls EN 13238, Reaction to fire tests for building products Conditioning procedures and g
30、eneral rules for selection of substrates EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests !EN 13823, Reaction to fire tests for building products Building products excluding floorings exposed to the thermal a
31、ttack by a single burning item“ EN ISO 354, Acoustics Measurement of sound absorption in a reverberation room (ISO 354:2003) EN ISO 9001:2000, Quality management systems Requirements (ISO 9001:2000) EN ISO 11654, Acoustics Sound absorbers for use in buildings Rating of sound absorption (ISO 11654:19
32、97) BS EN 15102:2007+A1:2011EN 15102:2007+A1:2011 (E) 6 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. !3.1 direct field of application of tests results outcome of a process (involving the application of defined rules) whereby a test result is d
33、eemed to be equally valid for variations in one or more of the product properties and/or intended end use applications 3.2 extended field of application of test results outcome of process (involving the application of defined rules that may incorporate calculation procedures) that predicts, for a va
34、riation of a product property and/or its intended end use application(s), a test result on the basis of one or more test results to the same test standard 3.3 product group range of products within defined limits of variability (defined by the manufacturer or a technical specification) of the produc
35、t parameters and, if relevant, end-use parameters, for which the reaction to fire performance remains unchanged (does not get worse) 3.4 product parameter aspect of a product (for example thickness, composition, density) which can vary and have an influence on the products fire performance 3.5 end u
36、se application real application of a product, in relation to all aspects that influence the behaviour of that product under different fire situations NOTE It covers aspects such as its quantity, its orientation, its position in relation to other adjacent products and its method of fixing (EN 13501-1
37、). 3.6 end use application parameter aspect of the mounting and fixing arrangement of a product reflecting/simulating its end-use application (for example type of substrate, fixing method, position and type of joints) which can affect the fire performance“ 4 Characteristics 4.1 !Reaction to fire Whe
38、re use of a wall covering product as internal finishes on walls, partitions and/or ceilings is subject to the reaction to fire regulation requirements, its reaction to fire class (including the additional classification on smoke production and flaming droplets/particles, if any) shall be determined
39、and declared according to EN 13501-1: a) either without the need for further testing (CWFT), as given in Table 1 1), if the wall covering product is proved to meet the requirements of the class given therein; 1) Table is the same as given in the Decision of the Commission 2010/82/EU of 2010-02-09 (s
40、ee OJEU L38 of 2010-02-11). BS EN 15102:2007+A1:2011EN 15102:2007+A1:2011 (E) 7 b) or based on testing of the wall covering product according to the standards referred to in EN 13501-1, when the wall covering product does not meet the requirements of Table 1 or where a higher class than the one in a
41、) is sought. NOTE Class F may be declared, which is an equivalent to “No Performance Determined“ (NPD) for this characteristic, when use of wall covering product is not subject to the national regulatory requirements on reaction to fire. Table 1 Classes of reaction to fire performance for decorative
42、 wall coverings in roll and panel form Product aMaximum mass per unit area (g/m2) Maximum thickness (mm) Class bWallcoverings on cellulose fibre base 190 0,9 D-s3, d2 Wallcoverings on cellulose fibre base and polymer coated or printed 470 0,7 Wallcoverings on a mixture of cellulose and polyester fib
43、re base 160 0,3 Wallcoverings on a mixture of cellulose and polyester fibre base and polymer coated or printed 410 0,5 Wallcoverings on polymer coated fabric base 510 0,7 Wallcoverings of woven textile with a backing consisting of cellulose fibre or cellulose and polyester fibre 450 0,8 Wallcovering
44、s of foamed PVC with a backing consisting of cellulose fibre or cellulose and polyester fibre 310 1,8 aProducts in accordance with EN 15102 mounted on a substrate of at least class A2-s1,d0 with a minimum thickness 12 mm and with minimum density 800 kg/m3using starch, or starch/PVA, or cellulose/PVA
45、 adhesive applied at a maximum 200 g/m2. bClass as provided for in Table 1 of the Annex to Commission Decision 2000/147/EC. When option b) is applied and where required by the test methods, the wallcovering product shall be tested in its end use conditions according to Annex B. In this case, the cla
46、ss declared shall be followed also by the associated mounting and fixing conditions (only if relevant for this class).“ 4.2 Release of formaldehyde The release of formaldehyde from the wallcovering product shall be declared when subject to regulatory requirement and may be declared otherwise. The fo
47、rmaldehyde release, when tested in accordance with Test C of EN 12149:1997 (as modified in Annex A of EN 12781:2001 or EN 13085:2001 for cork wallcovering products in panel form and roll form respectively) shall not exceed 120 mg/kg of wallcovering. If no formaldehyde or products containing formalde
48、hyde are added during the manufacturing process of the wallcovering product, and the raw materials are declared by the supplier to contain less than 120 mg/kg of formaldehyde, then testing is not necessary. 4.3 !Release of other dangerous substances“ 4.3.1 Heavy metals and specific elements 4.3.1.1
49、Requirements The migration of heavy metals and specific elements from the wallcovering product, expressed as mg/kg of wallcovering, shall not exceed the values given in !Table 2“ (after correction according to 4.3.1.2) when measured in accordance with Test A of EN 12149:1997. If none of these substances are added during the BS EN 15102:2007+A1:2011EN 1