EN 15869-2-2010 en Inland navigation vessels - Electrical shore connection three phase current 400 V up to 63 A 50 Hz - Part 2 Onshore unit safety requirements《内河航行船舶 电气连接 三相电流400 .pdf

上传人:appealoxygen216 文档编号:715417 上传时间:2019-01-04 格式:PDF 页数:16 大小:907.22KB
下载 相关 举报
EN 15869-2-2010 en Inland navigation vessels - Electrical shore connection three phase current 400 V up to 63 A 50 Hz - Part 2 Onshore unit safety requirements《内河航行船舶 电气连接 三相电流400 .pdf_第1页
第1页 / 共16页
EN 15869-2-2010 en Inland navigation vessels - Electrical shore connection three phase current 400 V up to 63 A 50 Hz - Part 2 Onshore unit safety requirements《内河航行船舶 电气连接 三相电流400 .pdf_第2页
第2页 / 共16页
EN 15869-2-2010 en Inland navigation vessels - Electrical shore connection three phase current 400 V up to 63 A 50 Hz - Part 2 Onshore unit safety requirements《内河航行船舶 电气连接 三相电流400 .pdf_第3页
第3页 / 共16页
EN 15869-2-2010 en Inland navigation vessels - Electrical shore connection three phase current 400 V up to 63 A 50 Hz - Part 2 Onshore unit safety requirements《内河航行船舶 电气连接 三相电流400 .pdf_第4页
第4页 / 共16页
EN 15869-2-2010 en Inland navigation vessels - Electrical shore connection three phase current 400 V up to 63 A 50 Hz - Part 2 Onshore unit safety requirements《内河航行船舶 电气连接 三相电流400 .pdf_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 15869-2:2010Inland navigation vessels Electrical shore connection, three phase current 400 V, up to 63 A, 50 HzPart 2: Onshore unit, safety requirementsBS EN 15869-2:2010 B

2、RITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 15869-2:2010. The UK participation in its preparation was entrusted to T e c h n i c a l Committee SME/32/-/11, Ships and marine technology - Intermodal, inland navigation and short sea shipping.A list of organizati

3、ons represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013. Published by BSI Standards Limited 2013.IS

4、BN 978 0 580 63978 4 ICS 47.020.60; 47.060; 93.140 Compliance with a British Standard cannot confer immunityfrom legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2013.Amendments issued since publicationDate T e x t

5、 a f f e c t e dBS EN 15869-2:2010EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15869-2 February 2010 ICS 47.020.60; 47.060; 93.140 English Version Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements

6、 Bateaux de navigation intrieure - Connexion au rseau lectrique terrestre, courant triphas 400 V, 63 A, 50 Hz -Partie 2: Unit terrestre, exigences de scurit Fahrzeuge der Binnenschifffahrt - Elektrischer Landanschluss, Drehstrom 400 V, bis 63 A, 50 Hz - Teil 2: Landseitiger Teil, sicherheitstechnisc

7、he Anforderungen This European Standard was approved by CEN on 25 December 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and b

8、ibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibil

9、ity of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary,

10、 Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: A

11、venue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15869-2:2009: EBS EN 15869-2:2010EN 15869-2:2010 (E) 2 Contents Page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and def

12、initions .6 4 Safety requirements 7 4.1 General7 4.2 Mechanical safety 8 4.3 Electrical safety8 4.4 Other provisions 9 5 Designation 9 6 Marking .9 7 Manufacturers declaration of conformity.9 Bibliography 10 Figures Figure 1 Block diagram of an electrical power-supply station with two connector unit

13、s. 7 BS EN 15869-2:2010EN 15869-2:2010 (E) 3 Foreword This document (EN 15869-2:2010) has been prepared by Technical Committee CEN/TC 15 “Inland navigation vessels”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publicatio

14、n of an identical text or by endorsement, at the latest by August 2010, and conflicting national standards shall be withdrawn at the latest by August 2010 EN 15869, Inland navigation vessels Electrical shore connection Three-phase current 400 V, up to 63 A, 50 Hz comprises: Part 1: General requireme

15、nts Part 2: Onshore unit, safety requirements Part 3: On-board unit, safety requirements According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republi

16、c, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 15869-2:2010EN 15869-2:2010 (E) 4 Introduction I

17、nland navigation vessels are equipped with a variety of electrical loads operating at 230 V or 400 V. While underway, continuous electrical power supply is provided by the onboard system from generators driven by diesel engines. When the vessel is berthed, these generators have to remain in operatio

18、n if there is no suitable onshore power supply available. In some cases, this leads to intense noise pollution both for the crew on the vessel itself and on other vessels lying alongside and also for residents ashore. The exhaust fumes are an additional pollution factor. The electrical shore connect

19、ions specified in this standard make it possible to provide the vessels with an electrical power supply while berthed and to eliminate noise and exhaust pollution. This calls for a uniform Europe-wide connection that can be activated and deactivated by the vessels crew in all ports and berths, if po

20、ssible, without requiring any assistance from shore-based personnel. This standard contains electrical safety requirements for the prevention of hazards in making, using and breaking the shore connection. Furthermore, cashless settlement for the electricity used shall be possible, ideally a standard

21、 Europe-wide payment system. Electrical shore connections with a permissible current of over 63 A as used for passenger ships with a hotelling function are not covered by this standard. . . BS EN 15869-2:2010EN 15869-2:2010 (E) 5 1 Scope This European Standard specifies requirements applicable to eq

22、uipment for shore-to-vessel supply of three-phase 400 V electrical power up to 63 A and a frequency of 50 Hz to berthed inland navigation vessels. This part of the European Standard specifies safety requirements for the onshore unit of the electrical shore connection. This part of the European Stand

23、ard applies only to the supply of inland navigation vessels in ports and berths for commercial shipping. Supply stations for leisure craft and houseboats in marinas or similar locations have to meet the requirements of IEC 60364-7-709. For low-voltage electrical installations, the requirements speci

24、fied in the HD 60364 and HD 384 series are applicable generally. The requirements in this part of EN 15869 supplement, amend or supersede some of the requirements in HD 60364/HD 384 Parts 1 to 6. Where no requirements are given in this part of EN 15869, the requirements specified in the HD 60364 and

25、 HD 384 are applicable; a detailed list is given in the Bibliography. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced d

26、ocument (including any amendments) applies. EN 15869-1, Inland navigation vessels Electrical shore connection, three-phase current 400 V, up to 63 A, 50 Hz Part 1: General requirements EN 14145, Holders for lifebuoys EN 60309-1, Plugs, socket-outlets and couplers for industrial purposes Part 1: Gene

27、ral requirements (IEC 60309-1:1999) EN 60309-2, Plugs, socket-outlets and couplers for industrial purposes Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories (IEC 60309-2:1999) EN 60309-4, Plugs, socket-outlets and couplers for industrial purposes Part 4: Switch

28、ed socket-outlets and connectors with or without interlock (IEC 60309-4:2006, modified) EN 60529, Degrees of protection provided by enclosures (IP code) (IEC 60529:1989) EN 60898-1, Electrical accessories Circuit-breakers for overcurrent protection for household and similar installations Part 1: Cir

29、cuit-breakers for a.c. operation (IEC 60898-1:2002, modified) EN 61008-1, Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) Part 1: General rules (IEC 61008-1:1996 + A1:2002, modified) HD 22.16.S2, Cables of rated voltages up to

30、 and including 450/750 V and having cross-linked insulation Part 16: Water resistant polychloroprene or equivalent synthetic elastomer sheathed cables BS EN 15869-2:2010EN 15869-2:2010 (E) 6 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 ele

31、ctrical shore connection equipment consisting of electrical power-supply station, cable set and feed unit for the supply of electrical power to inland navigation vessels in ports and at berths EN 15869-1:2010 3.2 electrical power-supply station shore-side part of the electrical shore connection with

32、 one or more connector units EN 15869-1:2010 3.3 connector unit unit for connecting an inland navigation vessel EN 15869-1:2010 3.4 activation medium system for activating the supply of power and cashless settlement of the costs EN 15869-1:2010 3.5 feed unit all the onboard devices for receiving the

33、 electrical power on board EN 15869-1:2010 BS EN 15869-2:2010EN 15869-2:2010 (E) 7 4 Safety requirements 4.1 General Key 1 fuse 2 overvoltage protector (if necessary) 3 three-phase meter (according to EN 15869-1) 4 circuit breaker 5 residual current operated circuit breaker 6 activation medium with

34、enabling contactor 7 socket outlet (according to EN 15869-1) Figure 1 Block diagram of an electrical power-supply station with two connector units The electrical power-supply station (see Figure 1) has a three-phase fuse, an overvoltage protector (optional) and one or more connector units. A connect

35、or unit consists of a circuit breaker, a residual current operated circuit breaker and 16 A (32 A and 63 A also optional) socket outlets, meter and activation medium. BS EN 15869-2:2010EN 15869-2:2010 (E) 8 The circuit breaker, residual current operated circuit breaker and socket outlets shall be pr

36、otected against misuse, e.g. by being located behind a door or flap that can only be opened with the activation medium (see EN 15869-1). The door or flap shall also be lockable even when the connection has been made so that it can only be opened with the activation medium. Furthermore, the connectio

37、n cables shall not have any crush points or shear points. The electrical power-supply station shall be equipped with lighting that sufficiently illuminates the socket outlets, electricity meter, circuit breaker and residual current operated circuit breaker, as well as the area where the operator sta

38、nds. In darkness, it shall be permanently illuminated or illuminated on approach for at least five minutes, e.g. by using a motion detector. A set of operating instructions shall be available explaining the necessary operating stages and containing the following information, at least: a) “Only use c

39、onnection cables according to HD 22.16, marked with H07RNF!“; b) “400 V, 50 Hz“; c) “Maximum permissible continuous load“ (11 kW at 16 A, 22 kW at 32 A or 44 kW at 63 A); d) “The socket outlet is protected by an RCCB (30 mA)“; e) “Information on laying the connection cable safely“; f) if appropriate

40、, the electricity price. The operating instructions shall be written in the local language of the place where the station is set up, as well as in German, Dutch, French, English, Polish, Serbo-Croat and Hungarian. In locally limited operating areas, the selection of languages can be reduced. The ins

41、tructions shall be available either on a display with a language selection or on a permanently fitted sign. 4.2 Mechanical safety The housing of the electrical power-supply station shall be sufficiently mechanically resistant, durable, flame-resistant and non-hydroscopic. It shall be permanently fit

42、ted and it shall not be possible to open it with commercially available tools. The electrical power-supply station shall be constructed for an ambient temperature of 20 C to +60 C. If necessary, these limiting values shall be increased according to the temperatures to be expected in the region where

43、 the installation site is located. 4.3 Electrical safety The complete electrical power-supply station shall have at least IP 55 degree of protection according to EN 60529, with the exception of the door or flap according to 4.1. Metal housings or housing components shall be connected to the on-site

44、earthing system. If the electrical power-supply station is fed with a voltage higher than stated in EN 15869-1, isolation (isolating transformer) shall be provided. The socket outlet shall: meet the requirements of EN 60309-1, EN 60309-2 and EN 60309-4; be all-pole switchable; be protected against s

45、hort-circuits with a circuit-breaker according to EN 60898-1 and BS EN 15869-2:2010EN 15869-2:2010 (E) 9 be fitted with an RCCB according to EN 61008-1, 30 mA. 4.4 Other provisions Any controls shall be fitted and the operating instructions displayed taking into account ergonomic aspects. The electr

46、ical power-supply station may be fitted with holders for lifebelts according to EN 14145 or additional equipment parts. This shall not impair the function and safety of the electrical power-supply station. The electrical power-supply station shall be supplied with assembly instructions and operating

47、 instructions containing information for safe assembly (e.g. base, access, operability). 5 Designation Designation of an electrical power-supply station of an electrical shore connection according to Part 2 (2) of this standard, of 32 A, with two connector units (2): Electrical power-supply station

48、EN 15869-2 32 2 6 Marking The electrical power-supply station of an electrical shore connection shall have permanent markings that include at least the following details: EN 15869-2; manufacturer or manufacturers mark; 7 Manufacturers declaration of conformity The manufacturer declares the conformit

49、y of the electrical shore connection with this standard. BS EN 15869-2:2010EN 15869-2:2010 (E) 10 Bibliography 1 IEC 60364-7-709, Low-voltage electrical installations Part 7-709: Requirements for special installations or locations Marinas and similar locations 2 HD 60364-1:2008, Low-voltage electrical installations Part 1: Fundamental principles, assessment of general characteristics, definitions (IEC 60364-1:2005, modified) 3 HD 60364-4-41:2007, Low-voltage electrical installations Part

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1