EN 50136-2-2013 en Alarm systems - Alarm transmission systems and equipment - Part 2 Requirements for Supervised Premises Transceiver (SPT).pdf

上传人:visitstep340 文档编号:716739 上传时间:2019-01-04 格式:PDF 页数:34 大小:1.68MB
下载 相关 举报
EN 50136-2-2013 en Alarm systems - Alarm transmission systems and equipment - Part 2 Requirements for Supervised Premises Transceiver (SPT).pdf_第1页
第1页 / 共34页
EN 50136-2-2013 en Alarm systems - Alarm transmission systems and equipment - Part 2 Requirements for Supervised Premises Transceiver (SPT).pdf_第2页
第2页 / 共34页
EN 50136-2-2013 en Alarm systems - Alarm transmission systems and equipment - Part 2 Requirements for Supervised Premises Transceiver (SPT).pdf_第3页
第3页 / 共34页
EN 50136-2-2013 en Alarm systems - Alarm transmission systems and equipment - Part 2 Requirements for Supervised Premises Transceiver (SPT).pdf_第4页
第4页 / 共34页
EN 50136-2-2013 en Alarm systems - Alarm transmission systems and equipment - Part 2 Requirements for Supervised Premises Transceiver (SPT).pdf_第5页
第5页 / 共34页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 50136-2:2013Alarm systems Alarm transmission systems and equipmentPart 2: Requirements for Supervised Premises Transceiver (SPT)BS EN 50136-2:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50136-2:2013. It supersedes BS EN 50

2、136-2-1:1998, BS EN 50136-2-2:1998, BS EN 50136-2-3:1998 and BS EN 50136-2-4:1998 which are withdrawn.The UK participation in its preparation was entrusted to Technical Committee GW/1/5, Transmission equipment and networks.A list of organizations represented on this committee can be obtained on requ

3、est to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013ISBN 978 0 580 67452 5ICS 13.320; 33.040.40Compliance with a

4、British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2013.Amendments/corrigenda issued since publicationDate Text affectedBS EN 50136-2:2013EUROPEAN STANDARD EN 50136-2 NORM

5、E EUROPENNE EUROPISCHE NORM August 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exp

6、loitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50136-2:2013 E ICS 13.320; 33.040.40 Supersedes EN 50136-2-1:1998 + corr. Apr.1998 + A1:2001, EN 50136-2-2:1998, EN 50136-2-3:1998, EN 50136-2-4:1998 English version Alarm systems - Alarm transmission systems

7、and equipment - Part 2: Requirements for Supervised Premises Transceiver (SPT) Systmes dalarme - Systmes et quipements de transmission dalarme - Partie 2: Exigences pour les transmetteurs des locaux surveills (SPT) Alarmanlagen - Alarmbertragungsanlagen und -einrichtungen - Teil 2: Anforderungen an

8、bertragungseinrichtungen (E) This European Standard was approved by CENELEC on 2013-08-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-da

9、te lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by transla

10、tion under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Den

11、mark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. 2 Content

12、s Foreword 4 1 Scope 6 2 Normative references . . 6 3 Terms, definitions and abbreviations . . 6 3.1 Terms and definitions . . 6 3.2 Abbreviations . 7 4 General requirements . . 7 4.1 General . . 7 4.2 SPT classification . . 8 5 Functional requirements . 8 5.1 General . . 8 5.2 Access levels . 8 5.3

13、 Remote access . . 9 5.4 Uploading and downloading of software and firmware . 9 5.5 Storage of parameters . 9 5.6 ATS and ATP fault reporting to the AS . . 9 5.7 Interface to the AS . 9 5.8 Monitoring of the transmission network interface(s) Fault reporting . .10 5.9 Power supply for the SPT . .10 5

14、.10 Event logging .10 6 Operation 12 6.1 Modes of acknowledgement operation . .12 6.2 SPT alarms . .12 6.3 Substitution security . .13 6.4 Information security . 13 7 Documentation .13 7.1 SPT documentation . 13 7.2 Marking and identification . .14 8 Housing and tamper protection Tamper protection r

15、equirements . .14 9 Tests 14 9.1 General . .14 9.2 General requirements . .14 9.3 Reduced functional test . 15 9.4 Functional tests . 15 Annex A (normative) Requirements of the interface between AS and SPT . 28 A.1 Parallel interface between AS and SPT . .28 A.2 Serial interface between AS and SPT .

16、 28 Bibliography .30 BS EN 50136-2:2013 EN 50136-2:2013 3 Tables Table 1 Event recording classification Events to be recorded . 11 Table 2 Event recording classification Memory capacity 2) definitions were updated; 3) requirements were aligned with new ATS categories of the revised system standard E

17、N 50136-1; 4) test methods were added; 5) the scope was changed to reflect the amalgamation of EN 50136-2-2:1998, EN 50136-2-3:1998and EN 50136-2-4:1998 and to achieve compatibility with application specific standards such asfire alarm transmission systems and social alarm transmission systems; 6) s

18、ignificant changes were made to the structure of the document to achieve general alarmtransmission requirements for SPT. Application specific requirements were removed; 7) the title was corrected to match the scope of the document. This revision was prepared to bring the procedures up-to-date with c

19、urrent technical developments,taking account of changes in the basic standards and the experience gained in the use of thestandard. Attention is drawn to the possibility that some of the elements of this document may be the subject ofpatent rights. CENELEC and/or CEN shall not be held responsible fo

20、r identifying any or all suchpatent rights. This European Standard is part of a series. This series is intended to give the requirements applicableto alarm transmission systems in general. EN 50136 consists of the following parts, under the general title Alarm systems Alarm transmissionsystems and e

21、quipment: Part 1: General requirements for alarm transmission systems; Part 2: Requirements for Supervised Premises Transceiver (SPT); Part 3: Requirements for Receiving Centre Transceiver (RCT); Part 4: Annunciation equipment used in alarm receiving centres (Technical Specification); Part 7: Applic

22、ation guidelines (Technical Specification); BS EN 50136-2:2013 EN 50136-2:2013 5 Part 9: Requirements for common protocol for alarm transmission using the Internet protocol(Technical Specification). BS EN 50136-2:2013 EN 50136-2:2013 6 1 Scope This European Standard specifies the general equipment r

23、equirements for the performance, reliability,resilience, security and safety characteristics of supervised premises transceiver (SPT) installed insupervised premises and used in alarm transmission systems (ATS). A supervised premisestransceiver can be a stand-alone device or an integrated part of an

24、 alarm system. These requirements also apply to SPTs sharing means of interconnection, control, communicationand power supplies with other applications. The alarm transmission system requirements and classifications are defined within EN 50136-1.Different types of alarm systems may in addition to al

25、arm messages also send other types ofmessages, e.g. fault messages and status messages. The term alarm is used in this broad sensethroughout the document. Additional requirements for the connection of specific types of alarmsystems are given in the relevant European Standards. Because the SPT can be

26、 applied in different applications (e.g. I Level 2: access to information about the operational status of the SPT. Access level 2 mayalso allow access to basic functional tests and the management of other Accesslevel 2 users; Level 3: maintenance and commissioning functions, access to affect the SPT

27、 configurationincluding the addition, removal or replacement of components and other operationsthat directly, or indirectly, may influence the functions of the SPT; Level 4: access to update the software and read-only functions. Access to level 2, 3 and level 4 functions shall require authorisation

28、with a key. Access at level 3 should be authorised by a user with level 2 access. Access at level 4 should beauthorised by a user with level 3 access. This may be achieved by a one time authorisation as part ofa service level agreement. Access at levels 2, 3 and 4 may be achieved providing authorisa

29、tion, equivalent to 1 000 000 keydiffers is achieved. Where it is possible to attempt to gain access more than 3 times in a 60-second period the SPT shallhave the ability to delay repeated attempts. After the third attempt, each further attempt shall beprevented for a minimum of 90 s. Where factory

30、default keys are provided, it shall not be possible to complete the SPT commissioningwithout first, changing these keys e.g. during installation. It shall not be possible to read any key thatprovides authorisation for access at levels 2, 3 or 4. BS EN 50136-2:2013 EN 50136-2:2013 9 5.3 Remote access

31、 Remote access to the SPT shall meet at least the same information security requirements that arerequired for alarm transmission as defined in EN 50136-1 for the appropriate category. 5.4 Uploading and downloading of software and firmware Where upload and download functions are provided, the upload

32、and download of software to a SPT isonly allowed to be performed by users with appropriate access level, as defined in 5.2. The software to be replaced by a software download shall be stored. If there is a loss of connection oranother transmission fault disrupts the download, the last fully function

33、al software version shall berestored, and the SPT shall work as before the unsuccessful download. EXAMPLE Procedure of a download: download software, check and validate the download, activate downloaded software. 5.5 Storage of parameters Power cycle or a boot up sequence shall not result in the los

34、s of any site specific data. The SPT shallreturn to normal operation. 5.6 ATS and ATP fault reporting to the AS Where the SPT is required to report an ATS and/or ATP failure to the AS as per EN 50136-1:2012,Table 5, this shall take place within the reporting times shown in EN 50136-1:2012, Table 3.

35、For an ATS with more than one ATP, as long as service is not lost, a single path line fault may be heldby the SPT for a period that is agreed between the interested parties until it is released to the AS. Where an AS includes the ability to display the status of each ATP the SPT may be configured to

36、 passindividual ATP failures to the AS within the reporting times shown in EN 50136-1:2012, Table 3. The manufacturers documentation should define the process for the reporting of ATS faults to the AS. 5.7 Interface to the AS The connections to the AS shall be monitored in accordance with EN 50136-1

37、. The maximum time to detect and generate an interface failure shall meet the requirements of theassociated application and shall not exceed the ATS reporting time of the appropriate category asspecified in EN 50136-1:2012, Table 3. To allow compatibility of equipment from different manufacturers, t

38、his European Standard specifiestwo electrical interfaces: parallel interface between AS and SPT, see A.1; serial interface between AS and SPT, see A.2. This does not exclude the use of any other type of interface to the AS, provided that the specificrequirements of this standard are met. The manufac

39、turer shall state in the associated documentation which type(s) of interface(s) to the ASare provided. BS EN 50136-2:2013 EN 50136-2:2013 10 5.8 Monitoring of the transmission network interface(s) Fault reporting If required by the ATS category, the SPT shall be configured to detect the failure of a

40、 transmissionnetwork interface and generate an ATP fault to the AS. The manufacturers documentation shall describe the process for monitoring and reporting the networkinterface fault to the AS. NOTE 1 The message generated by the SPT can indicate either an ATP fault or an interface fault. Where requ

41、ired, transmission network interface faults shall be reported within the time specified inEN 50136-1:2012, Table 3. For dual path category (Dx) ATSs, a fault on one of the transmission network interfaces shall bereported to the RCT over the remaining ATP within the time specified in EN 50136-1. NOTE

42、 2 An SPT network interface fault provides indication of a path fault. Monitoring the state of a transmission network interface should not be used to monitor the state of anassociated ATP. NOTE 3 An ATP can be in a failed state whilst the associated network interface is in an operational state. 5.9

43、Power supply for the SPT The SPT may be powered by the associated AS power supply (dedicated or shared) or by an integralSPT power supply. Where an integral SPT power supply is used, it shall meet the requirements of the most demandingassociated AS. 5.10 Event logging A logging function for all cate

44、gories of SPT except SP1 and DP1, shall be provided for the purposes ofproviding an audit trail and problem resolution. Dependent upon the ATS category where the SPT is applied, the events specified in Table 1 shall berecorded in the SPT. The means used to record the events shall be protected agains

45、t the accidental or deliberate deletionor alteration of the contents. The means of recording events shall be non-volatile and have a capacity complying with therequirements of Table 2. When the event recorder reaches maximum capacity, further events maycause the oldest events to be erased. The log s

46、hall record, in addition to the event, the time and date at which the event occurred. Thetiming resolution shall be a minimum of 1 s and it shall be accurate to the coordinated universal timewithin +/- 5 s. The SPT shall provide a means to adjust the date and time. Event optimisation is permitted, p

47、rovided that all diverse events are recorded and that the first and thelast repeated identical sequence of events in a 12 h period are recorded. Where this is done thenumber of repetitions need to be recorded. When required by Table 1, the logging of access to the SPT shall include user identificati

48、on. BS EN 50136-2:2013 EN 50136-2:2013 11 The inclusion of requirements to record events in Table 1 does not imply a requirement to provide theassociated function. Table 1 Event recording classification Events to be recorded # Event Events to be recorded SP1 SP2 SP3 SP4 SP5 SP6 DP1 DP2 DP3 DP4 1 Ala

49、rm message from and to the AS Op M M M M M Op M M M 2Positive alarm message acknowledgement from RCT Op M M M M M Op M M M 3 Negative alarm messageacknowledgement or timeout on alarmmessage acknowledgement from RCT Op M M M M M Op M M M 4 SPT primary power source failure b) pass-through. The manufacturer shall declare in the product documentation which of the two modes are supported. 6.1.2 Store-and-forward operation requirements When an alarm is received from the AS, the SPT shall secure the alarm