1、BSI Standards PublicationBS EN 50550:2011Power frequency overvoltage protective device for household and similar applications (POP)Incorporating corrigendum March 2012+A1:2014BS EN 50550:2011+A1:2014ForewordThis British Standard is the UK implementation of EN 50550:2011+A1:2014, incorporating corrig
2、endum March 2012. It supersedes BS EN 50550:2011, which will be withdrawn on 28 July 2017.The start and finish of text introduced or altered by corrigendum is indicated in the text by tags. Text altered by CENELEC corrigendum March 2012 is indicated in the text by .The UK participation in its prepar
3、ation was entrusted by Technical Committee PEL/23, Electrical accessories, to Subcommittee PEL/23/1, Circuit breakers and similar equipment for household use.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to incl
4、ude all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2014. Published by BSI Standards Limited 2014ISBN 978 0 580 85922 9ICS 29.120.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This Br
5、itish Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2011.Amendments/corrigenda issued since publicationDate Text affected30 April 2012 Implementation of CENELEC corrigendum March 201231 October 2014 Implementation of CENELEC amendment A1:2014: T
6、able A1 replacedBRITISH STANDARDEUROPEAN STANDARD EN 50550:2011+A1 NORME EUROPENNE EUROPISCHE NORM CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B -
7、 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50550:2011 E ICS 29.120.50 English version Power frequency overvoltage protective device for household and similar applications (POP) Dispositif de protection con
8、tre les surtensions frquence industrielle pour les applications domestiques et analoguesSchutzeinrichtung gegen netzfrequente berspannungen fr Hausinstallationen und fr hnliche Anwendungen This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply with the CEN/
9、CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to a
10、ny CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official ve
11、rsions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portug
12、al, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. September 2014 2 Foreword This European Standard was prepared by the CENELEC BTTF 128-1, Power frequency overvoltage protective device for household and similar applications. It was submitted to the formal vote and w
13、as approved by CENELEC as EN 50550 on 2011-01-15. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates are proposed: lates
14、t date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-01-15 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-01-15 This European Standard has been prepared under
15、a mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements of EC Directive 2004/108/EC. See Annex ZZ. _ This document (EN 50550:2011/A1:2014) has been prepared by CLC/TC 23E “Circuit breakers and similar devices for household and s
16、imilar applications“. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-07-28 latest date by which the national standards conflicting with this document have to be wi
17、thdrawn (dow) 2017-07-28 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Obj
18、ectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). Foreword to
19、 amendment A1BS EN 50550:2011+A1:2014 EN 50550:2011+A1:2014 (E) 3 Contents 1 Scope 52 Normative references 63 Terms and definitions . 74 Classification . 84.1 According to the method of construction . 84.2 According to the main protective device . 84.3 According to the range of ambient air temperatu
20、re (only for POP according to 4.2.2 and 4.2.3) . 84.4 According to the number of monitored line to neutral conductor voltages 85 Characteristics. 95.1 Summary of characteristics . 95.2 Limit values of the break times and non-actuating times . 96 Marking and other product information 96.1 Standard ma
21、rking 96.2 Additional marking . 107 Standard conditions for operation in service . 117.1 General 117.2 Conditions of installation . 117.3 Pollution degree 118 Requirements for construction and operation . 118.1 Mechanical design 118.2 Protection against electric shock 168.3 Dielectric properties and
22、 isolating capability . 168.4 Temperature rise . 168.5 Operating characteristic 168.6 Mechanical and electrical endurance 168.7 Performance at short-circuit currents 178.8 Resistance to mechanical shock and impact 178.9 Resistance to heat 178.10 Resistance to abnormal heat and to fire . 178.11 Agein
23、g of electronic components 178.12 Behaviour at low ambient air temperature 188.13 Electromagnetic compatibility . 188.14 Safety performance of overstressed POPs. 189 Tests . 189.1 General 189.2 Test condition 199.3 Verification of the influence of the POP on the correct operation of the main protect
24、ive device . 199.4 Test of dielectric properties . 219.5 Temperature rise . 219.6 Verification of the operating characteristics 219.7 Verification of the mechanical and electrical endurance . 239.8 Tests of creepage distances and clearances for electronic circuits (abnormal conditions) 249.9 Require
25、ments for capacitors and specific resistors and inductors used in electronic circuits . 279.10 Electromagnetic compatibility . 289.11 Test of safety performance of overstressed POPs . 329.12 Test of reliability of screws, current-carrying parts and connections 329.13 Test of reliability of terminals
26、 for external conductors . 329.14 Verification of protection against electric shock 329.15 Verification of resistance to mechanical shock and impact 339.16 Test of resistance to heat 339.17 Resistance to abnormal heat and to fire . 339.18 Verification of the correct operation at low ambient air temp
27、eratures for RCDs for use at temperatures between -25 C and +40 C 33BS EN 50550:2011+A1:2014 EN 50550:2011+A1:2014 (E) 4 Annex A (normative) Test sequences . 36Annex B (normative) Determination of clearances and creepage distances 37Annex C (informative) Examples of terminal designs . 39Annex D (nor
28、mative) Number of samples for full test procedure 42Annex ZZ (informative) Coverage of Essential Requirements of EC Directives . 44Bibliography 45Figures Figure 1 Minimum creepage distances and clearances measured in millimetres . 34Figure 2 Minimum creepage distances and clearances as a function of
29、 peak value of operating voltage 35Figure B.1 Illustrations of the application of creepage distances 38Figure C.1 Examples of pillar terminals . 39Figure C.2 Examples of screw terminals and stud terminals . 40Figure C.3 Examples of saddle terminals 41Figure C.4 Examples of lug terminals 41Tables Tab
30、le 1 Limit values of break times and non-actuating times 9Table 2 Minimum clearances and creepage distances 13Table 3 Maximum permissible temperatures under abnormal conditions . 26Table 4 Low frequency immunity test conditions . 29Table 5 High frequency immunity test conditions 30Table 6 Test condi
31、tions for electrostatic discharges 31Table 7 Emissions test conditions 31Table A.1 Test sequences . 36Table D.1 Number of samples for full test procedure 42Table D.2 Additional tests for POP already fully tested together with one kind of main protective device . 43BS EN 50550:2011+A1:2014 EN 50550:2
32、011+A1:2014 (E) 5 1 Scope This European Standard applies to power frequency overvoltage protection devices (hereafter referred to as “POP”) for household and similar uses, with a rated frequency of 50 Hz, a rated voltage 230 V a.c. (between phase and neutral), intended to be used in combination with
33、 a main protective device being either a CB in compliance with EN 60898-1 or EN 60898-2, a RCCB in compliance with EN 61008-1 or a RCBO in compliance with EN 61009-1. NOTE 1 Requirements for POPs in combination with switching devices other than a main protective device, or a POP integrated in a MPD,
34、 are under consideration. NOTE 2 Requirements for POP with functional earth connection regarding temporary overvoltage withstand are under consideration. NOTE 3 A POP is not a protective device to be used for automatic disconnection of the supply in the meaning of HD 60364-4-41. They are intended fo
35、r use in an environment with pollution degree 2 and overvoltage category III. They can be designed for factory assembly or for assembly on site. These devices are intended to mitigate the effects of power frequency overvoltages between phase and neutral conductor (e.g. caused by loss of neutral cond
36、uctor in the three phase supply upstream the POP) for downstream equipment by actuating the main protective device when an overvoltage between phase and neutral is detected. NOTE 4 To mitigate means in this context that the POP will provide protection in most cases of power frequency overvoltages. N
37、OTE 5 Protection in case of overvoltage between phases is under consideration. In case of phase to phase electrical supply system with rated voltage between phases 230 V a.c. and no neutral conductor, one line monitored POP in compliance to this standard can be used according to manufacturers instru
38、ction. The POP does not impair the protective function of the main protective device. This European Standard does not apply for protection against common mode over voltages. This European Standard does not apply to surge protective devices. This European Standard states: the definitions of terms use
39、d for POP (Clause 3); the classification of POP (Clause 4); the characteristics of POP (Clause 5); the preferred values of the operating and influencing quantities (Clause 5); the marking and information to be provided for POP (Clause 6); the standard conditions for installation and operation in ser
40、vice (Clause 7); the requirements for construction and operation (Clause 8); the list of minimum requirements to be tested (Clause 9). BS EN 50550:2011+A1:2014 EN 50550:2011+A1:2014 (E) 6 2 Normative references The following referenced documents are indispensable for the application of this document
41、. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50160:2010 Voltage characteristics of electricity supplied by public electricity networks EN 55014-1:2006 + A1:2009 Electromagnetic com
42、patibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emission (CISPR 14-1:2005 + A1:2008) EN 55022:2010 Information technology equipment Radio disturbance characteristics Limits and methods of measurement (CISPR 22:2008, mod.) EN 60065:2002 + corr. Aug. 2007
43、 Audio, video and similar electronic apparatus Safety requirements (IEC 60065:2001, mod.) EN 60384-14 Fixed capacitors for use in electronic equipment Part 14: Sectional specification Fixed capacitors for electromagnetic interference suppression and connection to the supply mains (IEC 60384-14) EN 6
44、0664-1:2007 Insulation coordination for equipment within low-voltage systems Part 1: Principles, requirements and tests (IEC 60664-1:2007) EN 60664-3 Insulation coordination for equipment within low-voltage systems Part 3: Use of coating, potting or moulding for protection against pollution (IEC 606
45、64-3) EN 60898-1:2003 + corr. Feb. 2004 + A1:2004 + A11:2005 + A12:2008 Electrical accessories Circuit breakers for overcurrent protection for household and similar installations Part 1: Circuit-breakers for a.c. operation (IEC 60898-1:2002, mod. + A1:2002, mod.) EN 60898-2:2006 Electrical accessori
46、es Circuit-breakers for overcurrent protection for household and similar installations Part 2: Circuit-breakers for a.c. and d.c. operation (IEC 60898-2:2000, mod. + A1:2003, mod.) EN 60998-2-3 Connecting devices for low-voltage circuits for household and similar purposes Part 2-3: Particular requir
47、ements for connecting devices as separate entities with insulation-piercing clamping units (IEC 60998-2-3) EN 61000 series Electromagnetic compatibility (EMC) (IEC 61000 series) EN 61008 series Residual current operated circuit-breakers without integral overcurrent protection for household and simil
48、ar uses (RCCBs) (IEC 61008 series) EN 61008-1:2004 + A11:2007 + A12:2009 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) Part 1: General rules (IEC 61008-1:1996, mod. + A1:2002, mod.) EN 61009 series Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) (IEC 61009 series) EN 61009-1:2004 + corr. Jul. 2006 + A11:2008 + A12:2009 + A13:2009 Residual current operated cir