EN 60099-1-1994 en Surge Arresters - Part 1 Non-Linear Resistor Type Gapped Surge Arresters for A C Systems (Incorporates Amendment A1 1999)《避雷器 第1部分 交流电系统用有间隙阀式避雷器 包含修改件A1-1999》.pdf

上传人:eventdump275 文档编号:717608 上传时间:2019-01-04 格式:PDF 页数:54 大小:658.61KB
下载 相关 举报
EN 60099-1-1994 en Surge Arresters - Part 1 Non-Linear Resistor Type Gapped Surge Arresters for A C Systems (Incorporates Amendment A1 1999)《避雷器 第1部分 交流电系统用有间隙阀式避雷器 包含修改件A1-1999》.pdf_第1页
第1页 / 共54页
EN 60099-1-1994 en Surge Arresters - Part 1 Non-Linear Resistor Type Gapped Surge Arresters for A C Systems (Incorporates Amendment A1 1999)《避雷器 第1部分 交流电系统用有间隙阀式避雷器 包含修改件A1-1999》.pdf_第2页
第2页 / 共54页
EN 60099-1-1994 en Surge Arresters - Part 1 Non-Linear Resistor Type Gapped Surge Arresters for A C Systems (Incorporates Amendment A1 1999)《避雷器 第1部分 交流电系统用有间隙阀式避雷器 包含修改件A1-1999》.pdf_第3页
第3页 / 共54页
EN 60099-1-1994 en Surge Arresters - Part 1 Non-Linear Resistor Type Gapped Surge Arresters for A C Systems (Incorporates Amendment A1 1999)《避雷器 第1部分 交流电系统用有间隙阀式避雷器 包含修改件A1-1999》.pdf_第4页
第4页 / 共54页
EN 60099-1-1994 en Surge Arresters - Part 1 Non-Linear Resistor Type Gapped Surge Arresters for A C Systems (Incorporates Amendment A1 1999)《避雷器 第1部分 交流电系统用有间隙阀式避雷器 包含修改件A1-1999》.pdf_第5页
第5页 / 共54页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 60099-1:1994 IEC 60099-1:1991 Incorporating Amendment No. 1 Surge arresters Part 1: Non-linear resistor type gapped surge arresters for a.c. systems The European Standard EN 60099-1:1994 with the incorporation of amendment A1:1999 has the status of a British Standard ICS 29.12

2、0.50 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS EN 60099-1:1994 This British Standard, having been prepared under the direction of the Eletrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 November 1994 BSI 03

3、 October 2001 The following BSI references relate to the work on this standard: Committee reference PEL/65 Draft for comment 90/25270 DC ISBN 0 580 23503 3 Cooperating organizations The European Committee for Electrotechnical Standardization (CENELEC), under whose supervision this European Standard

4、was prepared, comprises the national committees of the following countries: Austria Italy Belgium Luxembourg Denmark Netherlands Finland Norway France Portugal Germany Spain Greece Sweden Iceland Switzerland Ireland United Kingdom Amendments issued since publication Amd. No. Date Comments 13135 03 O

5、ctober 2001 See national forewordBS EN 60099-1:1994 BSI 03 October 2001 i Contents Page Cooperating organizations Inside front cover National foreword ii Foreword 2 Text of EN 60099-1 5 National annex NA (informative) Committees responsible 48BS EN 60099-1:1994 ii BSI 03 October 2001 National forewo

6、rd This British Standard has been prepared under the direction of the Electrotechnical Sector Board and is the English language version of EN 60099-1:1994 Surge arresters Part 1: Non-linear resistor type gapped surge arresters for a.c. systems including amendment A1:1999, published by the European C

7、ommittee for Electrotechnical Standardization (CENELEC). It is identical with IEC 60099-1:1991 including amendment 1:1999 published by the International Electrotechnical Commission (IEC). This British Standard replaces BS 2914:1972, which is withdrawn. The start and finish of text introduced or alte

8、red by amendment is indicated in the text by tags . Tags indicating changes to IEC text carry the number of the IEC amendment. For example, text altered by IEC amendment 1 is indicated by . From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-

9、1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references The British Standards which implement international or European publications referred to in this document

10、 may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index” or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of Britis

11、h Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 48, an inside back cov

12、er and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60099-1 May 1994 + A1 December 1999 UDC 621.316.933.1:620.1 Descriptors: Surge arrester, type gapped surge arrester, non-linear re

13、sistor English version S u r g e a r r e s t e r s Part 1: Non-linear resistor type gapped surge arresters for a.c. systems (including amendment A1:1999) (IEC 60099-1:1991 + A1:1999) Parafoudres Partie 1: Parafoudres rsistance variable avec clateurs pour rseaux courant alternatif (inclut lamendement

14、 A1:1999) (CEI 60099-1:1991 + A1:1999) berspannungsableiter Teil 1: Oberspannungsableiter mit nichtlinearen Widerstnden und Funkenstrecken fr Wechselspannungsnetze (enthlt nderung A1:1999) (IEC 60099-1:1991 + A1:1999) This European Standard was approved by CENELEC on 1993-12-08. Amendment A1 was app

15、roved by CENELEC on 1999-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nat

16、ional standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own langua

17、ge and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Swi

18、tzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1994 Copyright reserved to CENELEC members Ref. No. E

19、N 60099-1:1994 + A1:1999 EEN 60099-1:1994 BSI 03 October 2001 2 Foreword The CENELEC questionnaire procedure, performed for finding out whether or not the International Standard IEC 99-1:1991 could be accepted without textual changes, has shown that no common modifications were necessary for accepta

20、nce as a European Standard. The reference document was submitted to the CENELEC members for formal vote and was approved by CENELEC as EN 60099-1 on 8 December 1993. NOTE Finland, Norway and Switzerland have no obligation to implement this European Standard. The following dates were fixed: For produ

21、cts which have complied with the relevant national standard before 1994-12-01, as shown by the manufacturer or by a certification body, this previous standard may continue to apply for production until 1999-12-01. Annexes designated “normative” are part of the body of the standard. Annexes designate

22、d “informative” are given only for information. In this standard, Annex A and Annex ZA are normative and Annex B, Annex C, Annex D and Annex E are informative. Foreword to amendment A1 The text of document 37/223/FDIS, future amendment 1 to IEC 60099-1, prepared by IEC TC 37, Surge arresters, was su

23、bmitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to EN 60099-1:1994 on 2002-12-01. The following dates were fixed: Contents Page Foreword 2 Introduction 4 Section 1. General 1.1 Scope 5 1.2 Normative references 5 Section 2. Definitions 2.1 Surge arrester 7 2.2 Non

24、-linear resistor type gapped arrester 7 2.3 Series gap of an arrester 7 2.4 Non-linear series resistor of an arrester 7 2.5 Section of an arrester 7 2.6 Unit of an arrester 7 2.7 Pressure-relief device of an arrester 7 2.8 Rated voltage of an arrester 7 2.9 Rated frequency of an arrester 7 2.10 Disr

25、uptive discharge 8 2.11 Puncture 8 2.12 Flashover 8 2.13 Sparkover of an arrester 8 2.14 Impulse 8 2.15 Rectangular impulse 8 2.16 Peak (crest) value of an impulse 8 2.17 Front of an impulse 8 2.18 Tail of an impulse 8 2.19 Full-wave voltage impulse 8 2.20 Chopped voltage impulse 8 2.21 Prospective

26、peak (crest) value of a chopped voltage impulse 9 2.22 Virtual origin of an impulse 9 2.23 Virtual front time of an impulse (T 1 )9 2.24 Virtual steepness of the front of an impulse 9 2.25 Virtual time to half value on the tail of an impulse (T 2 )9 2.26 Designation of an impulse shape 9 2.27 Standa

27、rd lightning voltage impulse 9 2.28 Switching voltage impulse 9 2.29 Virtual duration of the peak of a rectangular impulse 9 2.30 Virtual total duration of a rectangular impulse 10 2.31 Peak (crest) value of opposite polarity of an impulse 10 2.32 Discharge current of an arrester 10 latest date of p

28、ublication of an identical national standard (dop) 1994-12-01 latest date of withdrawal of conflicting national standards (dow) 1994-12-01 latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2000-09-01 la

29、test date by which the national standards conflicting with the amendment have to be withdrawn (dow) 2002-12-01EN 60099-1:1994 BSI 03 October 2001 3Page 2.33 Nominal discharge current of an arrester 10 2.34 Follow-current of an arrester 10 2.35 Residual voltage (discharge voltage) of an arrester 10 2

30、.36 Power-frequency sparkover voltage of an arrester 10 2.37 Impulse sparkover voltage of an arrester 10 2.38 Front-of-wave impulse sparkover of an arrester 10 2.39 Standard lightning impulse sparkover voltage of an arrester 10 2.40 Time to sparkover of an arrester 10 2.41 Impulse sparkover-voltage/

31、time curve 10 2.42 Prospective current 11 2.43 Type tests (design tests) 11 2.44 Routine tests 11 2.45 Acceptance tests 11 2.46 Protective characteristics of an arrester 11 2.47 Arrester disconnector 11 Section 3. Identification and classification 3.1 Arrester identification 13 3.2 Arrester classifi

32、cation 13 Section 4. Standard ratings 4.1 Standard voltage ratings 15 4.2 Standard rated frequencies 15 4.3 Standard nominal discharge currents 15 4.4 Service conditions 15 4.4.1 Normal service conditions 15 4.4.2 Abnormal service conditions 15 Section 5. Requirements 5.1 Power-frequency sparkover v

33、oltage 17 5.2 Standard lightning impulse sparkover voltage 17 5.3 Front-of-wave impulse sparkover voltage 17 5.4 Switching impulse sparkover voltage 17 5.5 Lightning impulse residual voltage 17 5.6 Switching impulse residual voltage 17 5.7 High-current impulse withstand 17 5.8 Long-duration current

34、withstand 17 5.9 Operating-duty 18 5.10 Pressure-relief 18 5.11 Disconnectors 18 5.11.1 Disconnector withstand 18 5.11.2 Disconnector operation 18 Page Section 6. General testing procedure 6.1 Test samples and measurements 19 6.2 Power-frequency voltage tests 19 6.3 Wet tests 19 6.4 Artificial-pollu

35、tion tests 19 Section 7. Routine and acceptance tests 7.1 Routine tests 21 7.2 Acceptance tests 21 Section 8. Type tests (design tests) 8.1 General 23 8.2 Power-frequency voltage sparkover tests 23 8.3 Voltage impulse sparkover tests 24 8.3.1 General 24 8.3.2 Standard lightning impulse sparkover tes

36、t 24 8.3.3 Lightning impulse sparkover-voltage/time curve test 25 8.3.4 Front-of-wave impulse sparkover test 25 8.3.5 Switching impulse sparkover-voltage/time curve test 26 8.4 Measurement of residual voltage 26 8.4.1 Lightning impulse residual voltage 26 8.4.2 Switching impulse residual voltage 27

37、8.5 Current impulse withstand tests 27 8.5.1 General 27 8.5.2 High-current impulse test 28 8.5.3 Long-duration current impulse test 28 8.6 Operating-duty test 30 8.7 Short-circuit tests 32 8.7.1 General 32 8.7.2 Preparation of the test samples 32 8.7.3 Mounting of the test sample 33 8.7.4 Evaluation

38、 of test results 36 8.7.5 High current short-circuit tests 36 8.7.6 Low current short-circuit test 37 8.8 Tests of arrester disconnectors 37 8.8.1 General 37 8.8.2 Current impulse withstand and operating-duty tests 37 8.8.3 Disconnector operation 38EN 60099-1:1994 BSI 03 October 2001 4Page Annex A (

39、normative) Abnormal service conditions 41 Annex B (informative) Typical information given with enquiries and tenders 41 Annex C (informative) Selection of the long-duration discharge class of heavy-duty arresters 43 Annex D (informative) Typical circuit for a distributed-constant impulse generator f

40、or the long-duration current impulse test according to 8.5.3 44 Annex E (informative) Typical circuit for operating-duty test according to 8.6 45 Annex ZA (normative) Other international publications quoted in this standard with the references of the relevant European publications 47 Figure 1 Front-

41、of-wave voltage sparkover test 25 Figure D.1 Typical circuit for a distributed-constant impulse generator for the long-duration impulse test 44 Figure E.1 Typical test-circuit diagram for operating-duty test 46 Table 1 Standard voltage ratings (kV r.m.s.) 15 Table 2 Parameters for wet tests 20 Table

42、 3 Arrester classification and test requirements 24 Table 4 High-current impulse test 28 Table 5 Parameters for the long-duration current impulse test on heavy-duty 10 000 A arresters 29 Table 6 Requirements for the long-duration current impulse test on 10 000 A light-duty, 5 000 A and 2 500 A arres

43、ters 30 Table 7 Requirements for pressure-relief tests 32 Table 8 Maximum impulse sparkover (see 8.3) and residual voltages (see 8.4) Values referred to U r 39 Table 9 Required currents for short-circuit tests 40 Table C.1 Transmission line characteristics 43 Introduction The major changes to the pr

44、evious edition affect the following subjects: measurement of residual voltage; operating-duty test; pressure-relief test; standardized sparkover and residual voltages; addition of annex for information to be given on enquiries and tenders. The changes introduced are limited to the agreed upon subjec

45、ts. Additional work was not considered due to the changing technology and the present limited use of gapped surge arresters. Appendix D of the second edition of this standard has been deleted and issued as a separate Report, IEC 99-3. The present developing gapless surge arresters using metal oxide

46、resistors will be the subject of the future IEC 99-4. An application guide is under revision and will be published as IEC 99-5. It will supersede IEC 99-1A.EN 60099-1:1994 BSI 03 October 2001 5 Section 1. General 1 1.1 Scope This part of International Standard IEC 99 applies to surge protective devi

47、ces designed for repeated operation to limit voltage surges on a.c. power circuits and to interrupt power-follow current. In particular, it applies to surge arresters consisting of single or multiple spark gaps in series with one or more non-linear resistors. 1.2 Normative references The following s

48、tandards contain provisions which, through reference in this text, constitute provisions of this part of International Standard IEC 99. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this part are encouraged to

49、 investigate the possibility of applying the most recent editions of the standards indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. IEC 60, High-voltage test techniques. IEC 71-2:1976, Insulation co-ordination Part 2: Application guide. IEC 99-3:1990, Surge arresters Part 3: Artificial pollution testing of surge arresters.6 blank