1、BRITISH STANDARD BS EN 60966-4:2003 Radio frequency and coaxial cable assemblies Part 4: Sectional specification for semi-rigid coaxial cable assemblies The European Standard EN 60966-4:2003 has the status of a British Standard ICS 33.120.10 BS EN 60966-4:2003 This British Standard was published und
2、er the authority of the Standards Policy and Strategy Committee on 17 November 2003 BSI 17 November 2003 ISBN 0 580 42914 8 National foreword This British Standard is the official English language version of EN 60966-4:2003. It is identical with IEC 60966-4:2003. It supersedes BS EN 60966-4:1996 whi
3、ch is withdrawn. The UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables, wires, waveguides, r.f. connectors, r.f. and microwave passive components and accessories, to Subcommittee EPL/46/1, Coaxial cables, which has the responsibility to: A list of organizations
4、represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondenc
5、e Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itsel
6、f confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them
7、in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 19 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEURO
8、PEAN STANDARD EN 60966-4 NORME EUROPENNE EUROPISCHE NORM October 2003 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2003 CENEL
9、EC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60966-4:2003 E ICS 33.120.10 Supersedes EN 60966-4:1994English version Radio frequency and coaxial cable assemblies Part 4: Sectional specification for semi-rigid coaxial cable assemblies
10、 (IEC 60966-4:2003) Ensembles de cordons coaxiaux et de cordons pour frquences radiolectriques Partie 4: Spcification intermdiaire pour cordons coaxiaux semi-rigides (CEI 60966-4:2003) Konfektionierte Koaxial- und Hochfrequenzkabel Teil 4: Rahmenspezifikation fr halbstarre konfektionierte Koaxialkab
11、el (IEC 60966-4:2003) This European Standard was approved by CENELEC on 2003-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date list
12、s and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the re
13、sponsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland,
14、Ireland, Italy, Lithuania, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. EN 60966-4:2003 - 2 - Foreword The text of document 46A/551/FDIS, future edition 2 of IEC 60966-4, prepared by SC 46A, Coaxial cables, of IEC TC 46, Cables, wires, wa
15、veguides, r.f. connectors, r.f. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60966-4 on 2003-10-01. This European Standard supersedes EN 60966-4:1994. The major change with respect to EN 60966-4:1994 is the referen
16、ce to the 1999 edition of the generic specification EN 60966-1. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2004-07-01 latest date by which the national standards conflict
17、ing with the EN have to be withdrawn (dow) 2006-10-01 This sectional specification is to be read with EN 60966-1:1999, Radio frequency and coaxial cable assemblies Part 1: Generic specification - General requirements and test methods. Annexes designated “normative“ are part of the body of the standa
18、rd. In this standard, annex ZA is normative. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60966-4:2003 was approved by CENELEC as a European Standard without any modification. _ Page2 EN609664:200360966-4 IEC:2003 3 CONTENTS 1 Scope.4 2 Normativ
19、e references4 3 Definitions4 4 Design and manufacturing requirements .5 4.1 Cable design and construction .5 4.2 Connector design and construction 5 4.3 Outline and interface dimensions .5 5 Workmanship, marking and packaging6 6 Quality assessment.7 7 Test methods General7 8 Electrical tests 7 9 Mec
20、hanical robustness tests .8 10 Environmental tests 8 11 Specialized test methods 8 12 Test schedules.9 Annex ZA (normative) Normative references to international publications with their corresponding European publications .18 Bibliography19 Table 1 Grouping of tests for specification purposes.10 Tab
21、le 2 Test schedule11 Page3 EN609664:200360966-4 IEC:2003 4 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES Part 4: Sectional specification for semi-rigid coaxial cable assemblies 1 Scope This part of IEC 60966 is a sectional specification that relates to semi-rigid coaxial cable assemblies operating in
22、 the transverse electromagnetic mode (TEM). It establishes uniform requirements for testing the electrical, mechanical and climatic properties of semi-rigid cable assemblies composed of semi-rigid coaxial cables and coaxial connectors. NOTE 1 The numbering of the Clauses is the same as in the generi
23、c specification. NOTE 2 For the purpose of this sectional specification, a cable assembly is always regarded as an integral unit. All specifications apply to the finished assembly and not to individual and non-assembled parts thereof. NOTE 3 This sectional specification should be supplemented with d
24、etail specifications giving additional details as required by the particular application. This application will not necessarily require all tests. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition
25、cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60096-2:1988, Radio-frequency cables Part 2: Relevant cable specifications IEC 60410:1973, Sampling plans and procedures for inspection by attributes IEC 60966-1:1999, Radio-f
26、requency and coaxial cable assemblies Part 1: Generic specification General requirements and test methods IEC 61169 (all parts), Radio-frequency connectors IEC 61196 (all parts) , Radio-frequency cables ISO 9000, Quality management systems Fundamentals and vocabulary 3 Definitions For the purposes o
27、f this document, the definitions given in IEC 60966-1 apply. Page4 EN609664:200360966-4 IEC:2003 5 4 Design and manufacturing requirements The subclauses of Clause 4 of IEC 60966-1 are replaced by the following. 4.1 Cable design and construction Cables should conform to IEC 60096-2 or IEC 61196. Whe
28、re cable designs deviating from these publications are required they shall comply with the requirements of the detail specification. If required, the manufacturer may use additional protective tubing or cable deviating from IEC 61196, in order to comply with the requirements of the detail specificat
29、ion. The materials used in the cable shall be given as engineering information in the detail specification. 4.2 Connector design and construction Connectors should conform to IEC 61169. Where connector designs deviating from IEC 61169 are required, the interface should conform to the relevant part o
30、f IEC 61169 where available and shall comply with the requirements of the detail specification. The materials used in the connector shall be given as engineering information in the detail specification. 4.3 Outline and interface dimensions The outline and interface dimensions shall be in accordance
31、with the detail specification of the cable assembly. The length, unless otherwise specified in the detail specification, is defined as between the reference planes of the connectors. In the case of right-angle connectors, the length applies to the axis of the connectors (see Figure 1) If not indicat
32、ed in the detail specification, the length tolerance shall be 1 % for cables equal to, or longer than, 300 mm and 3 mm for cables shorter than 300 mm. Page5 EN609664:200360966-4 IEC:2003 6 Length IEC 2050/03Figure 1 Length definition of cable assemblies 5 Workmanship, marking and packaging Clause 5
33、of IEC 60966-1 applies, except for the following addition. Cable assemblies made in accordance with this sectional specification comprise a section of cable and two connectors. When specified in the detail specification, the assembly may additionally include markers for identification of the assembl
34、y and interconnecting ends. End caps and other accessories may also be specified. NOTE Occasionally the cable assembly will comprise only a cable and one connector. Semi-flexible cable Connector 1 Connector 2 Marking end 1 a Marking end 2 a Identification a IEC 2051/03aWhen specified NOTE Semi-flexi
35、ble cable should be semi-rigid cable. . Figure 2 Example of a cable assembly Page6 EN609664:200360966-4 IEC:2003 7 6 Quality assessment Clause 6 of IEC 60966-1 applies. 7 Test methods General Clause 7 of IEC 60966-1 applies. 8 Electrical tests Clause 8 of IEC 60966-1 is applicable, except as follows
36、. Addition: 8.1 Reflection properties Whilst the parameter return loss (A r ) is preferred, the reflection factor (r) or the VSWR may be specified where A r= 20 log 10r and VSWR = (1 + r )/ (1 r ). Replacement: 8.4 Insertion loss stability The test is not applicable for semi-rigid coaxial cable asse
37、mblies. 8.6 Stability of electrical length The test is not applicable for semi-rigid coaxial cable assemblies. 8.7 Phase difference 8.7.1 Object To measure the difference between two or more cable assemblies.The phase difference shall not exceed the limits specified in the relevant detail specificat
38、ion. If more than two cable assemblies belong to a matched set, the reference cable shall be clearly marked. Addition: 8.9.1 Requirements The transfer impedance shall be below the specified limit. When the test is performed at 30 MHz, the detail specification should indicate one of the preferred max
39、imum values as follows: 30 300 3 Page7 EN609664:200360966-4 IEC:2003 8 8.9.2 Information to be given in the detail specification a) Mounting details of the cable assembly under test. b) Limit of the transfer impedance. 8.10.3 Addition: 8.10.3.1 If not indicated in the detail specification, the test
40、shall be carried out at sea-level. Additionally, high altitude may be required by the detail specification. Preferred values are: Sea-level: 86 kPa to 106 kPa 10 km: 25 kPa 20 km: 4,4 kPa 9 Mechanical robustness tests Clause 9 of IEC 60966-1 is applicable, except as follows. 9.2 Flexure The test is
41、not applicable to semi-rigid coaxial cable assemblies. 9.3 Flexing endurance The test is not applicable to semi-rigid coaxial cable assemblies. 9.4 Cable assembly crushing The test is not applicable to semi-rigid coaxial cable assemblies. 9.6 Multiple bending The test is not applicable to semi-rigid
42、 coaxial cable assemblies. 10 Environmental tests Clause 10 of IEC 60966-1 is applicable, except as follows. Addition: 10.2.1 The non-destruction of the cable assembly by the tests depends strongly on the dimensions, shape and mechanical stress arising from misfits. When applicable, the mechanical d
43、etails shall be indicated in the detail specification. 11 Specialized test methods Clause 11 of IEC 60966-1 applies. Page8 EN609664:200360966-4 IEC:2003 9 12 Test schedules 12.1 General In addition to the electrical, mechanical and environmental test requirements, the detail specification shall indi
44、cate the tests to be performed with the corresponding inspection levels, acceptance quality levels and periodicities. Whenever possible, in the place of individual tests, complete test groups from Table 1 shall be specified, for example, Eb, Ep, Vt. Page9 EN609664:200360966-4 IEC:2003 10 Table 1 Gro
45、uping of tests for specification purposes Recommended grouping of tests Recommended severities Group Subclause Tests Periodicity IL cAQL dn ac bNotes 7.2 Visual inspection Lot-by-lot S3 4.0 Ba 7.3 Dimensions inspection Lot-by-lot S3 4.0 8.1 Reflection properties Lot-by-lot II 1.0 Eh 8.3 Insertion lo
46、ss Lot-by-lot II 1.0 8.10 Voltage proof Lot-by-lot II 1.0 8.11 Insulation resistance Lot-by-lot II 1.0 Eb 8.12 Inner and outer conductor continuity Lot-by-lot II 1.0 Ez 8.2 Uniformity of impedance Lot-by-lot II 1.0 8.5 Propagation time Lot-by-lot 100 % 2 8.7 Phase difference Lot-by-lot 100 % 2 Ep 8.
47、8 Phase variation with temperature 3 years 3 0 1 Ee 8.9 Screening effectiveness 3 years 3 0 Et 8.14 Power rating 3 years 3 0 9.1 Tensile test 3 years 3 0 1 Mn 9.5 Torque 3 years Vv 10.2 Vibration, bumps and shock 3 years 3 0 Vc 10.3 Climatic sequence 3 years 3 0 10.4 Damp heat, steady state 3 years
48、e 10.5 Rapid change of temperature 3 years e 10.6 Solvents and contaminating fluids 1 year e Vt 10.8 Salt mist and sulphur dioxide 1 year e 10.7 Water immersion 3 years e 10.9 Dust tests 3 years e Vf 10.10 Flammability 3 years e NOTE 1 If the manufacturer wishes to replace these tests by analogous t
49、ests made on the connectors and the cable separately, he should demonstrate to the customer that the tests are such that the requirements of the detail specification will have been met at the final stage of inspection (modification of IEC QC 001002, 12.3.4 11). NOTE 2 Only one of the tests 8.5 or 8.7 should be specifi