1、BSI Standards PublicationFibre optic interconnecting devices and passive components Basic test and measurement proceduresPart 3-51: Examinations and measurements Pin gauge withdrawal force for rectangular ferrule multi-fibre connectorsBS EN 61300-3-51:2014National forewordThis British Standard is th
2、e UK implementation of EN 61300-3-51:2014. It isidentical to IEC 61300-3-51:2014.The UK participation in its preparation was entrusted by TechnicalCommittee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre opticinterconnecting devices and passive components.A list of organizations represented o
3、n this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 79343 1I
4、CS 33.180.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 December 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN
5、61300-3-51:2014EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 61300-3-51 November 2014 ICS 33.180.20 English Version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-51: Examinations and measurements - Pin gaugewithdrawal force for rectan
6、gular ferrule multi-fibre connectors (IEC 61300-3-51:2014) Dispositifs dinterconnexion et composants passifs fibres optiques - Procdures fondamentales dessais et de mesures - Partie 3-51: Examens et mesures - Forcedextraction dune broche calibre pour des connecteursmultifibres frule rectangulaire (C
7、EI 61300-3-51:2014) Lichtwellenleiter - Verbindungselemente und passiveBauteile - Grundlegende Prf- und Messverfahren - Teil 3-51: Untersuchungen und Messungen - Prfstift-Ausziehkraft von rechteckigen Ferrulen von Mehrfachfasersteckverbindern (IEC 61300-3-51:2014) This European Standard was approved
8、 by CENELEC on 2014-11-14. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national
9、standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own la
10、nguage and notified to the CEN-CENELEC Management Centre has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, Fra
11、nce, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de No
12、rmalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61300-3-51:2014 E EN 61300-3-51:2014
13、- 2 - Foreword The text of document 86B/3817/FDIS, future edition 1 of IEC 61300-3-51, prepared by SC 86B “Fibre optic interconnecting devices and passive components” of IEC/TC 86 “Fibre optics“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61300-3-51:2014. The followi
14、ng dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-08-14 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2017-11-14 Attention
15、is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61300-3-51:2014 was approved by CE
16、NELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated : IEC 61300-3-49 NOTE Harmonized as EN 61300-3-49. BS EN 61300-3-51:2014- 3 - EN 61300-3-51:2014 Annex ZA (normative) Normative references t
17、o international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest ed
18、ition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex
19、 is available here: www.cenelec.eu Publication Year Title EN/HD Year IEC 61300-3-1 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination EN 61300-3-1 - IEC 61754-5 - Fibre optic connector in
20、terfaces - Part 5: Type MT connector family EN 61754-5 - IEC 61754-7-1 - Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7-1: Type MPO connector family - One fibre row EN 61754-7-1 - IEC 61754-7-2 - Fibre optic interconnecting devices and passive
21、components - Fibre optic connector interfaces - Part 7-2: Type MPO connector family - Two fibre rows EN 61754-7-2 - IEC 61754-10 - Fibre optic connector interfaces - Part 10: Type Mini-MPO connector family EN 61754-10 - IEC 61754-18 - Fibre optic connector interfaces - Part 18: Type MT-RJ connector
22、family EN 61754-18 - BS EN 61300-3-51:2014 2 IEC 61300-3-51:2014 IEC 2014 CONTENTS 1 Scope 6 2 Normative references 6 3 General description . 7 3.1 General . 7 3.2 Test conditions . 7 4 Apparatus 7 4.1 Fixture 7 4.2 Pin gauge chuck . 7 4.3 Plug gauge chuck . 7 4.4 Pin gauge . 7 4.5 Plug gauge . 8 4.
23、6 Weight 9 4.7 Tensile testing machine 9 5 Procedure 9 5.1 Method A: Method using the weight (Figure 3) 9 5.2 Method B: Method using the tensile testing machine (Figure 4) . 10 6 Details to be specified . 12 Annex A (informative) Experimental verification of the interchangeability between the pin ga
24、uge insertion force and the pin gauge withdrawal force . 13 A.1 General . 13 A.2 Measurement system 13 A.3 Measurement sample 13 A.4 Measurement procedure . 14 A.5 Measurement results . 14 A.6 Conclusion 15 Annex B (informative) Experimental verification of compatibility of Method A (method using th
25、e weight) and Method B (method using the tensile testing machine) . 16 Bibliography 17 Figure 1 Pin gauge. 8 Figure 2 Plug gauge for guide pin holes . 8 Figure 3 Method A for examination of pin gauge/plug gauge withdrawal force (method using the weight) . 10 Figure 4 Method B for examination of pin
26、gauge/plug gauge withdrawal force (method using the tensile testing machine) . 11 Figure A.1 Measurement system 13 Figure A.2 Insertion/withdrawal force measurement results 14 Figure B.1 Relation between the withdrawal force values measured by Method A and Method B 16 BS EN 61300-3-51:2014IEC 61300-
27、3-51:2014 IEC 2014 3 Table 1 Test conditions 7 Table 2 Dimensions of the pin gauge . 8 Table 3 Dimensions for plug gauge for guide pin holes 9 Table A.1 Guide hole pitch of measurement samples . 14 BS EN 61300-3-51:2014 6 IEC 61300-3-51:2014 IEC 2014 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE C
28、OMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 3-51: Examinations and measurements Pin gauge withdrawal force for rectangular ferrule multi-fibre connectors 1 Scope This part of IEC 61300 is intended to describe the procedure required to measure the pin gauge withdrawal force for rectangular f
29、errule multi-fibre connectors. This measurement can be used as an alternative to the measurement of the pin gauge insertion force, both of which evaluate the fit of the pin gauge(s) into the guide pin hole(s) of the female-type connector. The experimental verification of interchangeability between t
30、hem is shown in Annex A. For the male-type connector, IEC 61300-3-49 is applied to evaluate how securely the guide pins are retained in the guide holes. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its appl
31、ication. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinati
32、ons and measurements Visual examination IEC 61754-5, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 5: Type MT connector family IEC 61754-7-1, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 7-1: Type
33、MPO connector family One fibre row1IEC 61754-7-2, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 7-2: Type MPO connector family Two fibre rows1 IEC 61754-10, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces
34、Part 10: Type Mini-MPO connector family IEC 61754-18, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 18: Type MT-RJ connector family _ 1To be published. BS EN 61300-3-51:2014IEC 61300-3-51:2014 IEC 2014 7 3 General description 3.1 General This measur
35、ement method is applied for optical connectors specified in IEC 61754-5, IEC 61754-7-1, IEC 61754-7-2, IEC 61754-10 and IEC 61754-18. Two methods using weights or a tensile testing machine are described in this standard. The optical connector is held using a fixture. For the measurement for a single
36、 guide pin hole, the pin gauge is placed in a pin gauge chuck and the weight or the tensile testing machine is connected to the pin gauge chuck. For the measurement for two guide pin holes, the plug gauge is placed in a plug gauge chuck and the weight or the tensile testing machine is connected to t
37、he plug gauge chuck. By using the plug gauge, it is possible to check not only the size of each guide pin hole but also the relative position and the relative angle between two guide pin holes. 3.2 Test conditions For a precise measurement such as design verification, the test conditions shall be co
38、ntrolled accurately as required in Table 1. Table 1 Test conditions Temperature C Relative humidity % RH 22,0 24,0 50,0 10,0 4 Apparatus 4.1 Fixture The measurement shall not be affected by the connector fixture. The position and direction of the connector during the test shall not change as the tes
39、t is repeated. The connector shall be placed in the fixture so that the front face of the connector housing is retained by the fixture as shown in Figure 3 and Figure 4. 4.2 Pin gauge chuck The pin gauge chuck shall have a pin gauge retention force much greater than the required connector pin gauge
40、withdrawal force, typically more than 200 N when using a tensile testing machine. The connection of the pin gauge to the weight or the tensile testing machine chuck shall not affect the measurement. 4.3 Plug gauge chuck The plug gauge chuck shall have a plug gauge retention force much greater than t
41、he required connector plug gauge withdrawal force, typically more than 200 N, when using a tensile testing machine. The connection of the plug gauge to the weight or the tensile testing machine chuck shall not affect the measurement. 4.4 Pin gauge Figure 1 and Table 2 show the pin gauge and dimensio
42、ns of the pin gauge. The pin gauge shall have the required dimensions as specified in IEC 61754-5. BS EN 61300-3-51:2014 8 IEC 61300-3-51:2014 IEC 2014 Figure 1 Pin gauge Table 2 Dimensions of the pin gauge Reference Dimensions mm Remarks Minimum Maximum A B aBA BB BC b0,698 5 10,8 0,2 0,2 6,0 0,699
43、 0 11,2 0,4 0,5 aTypical dimensions. bSurface roughness Rz= 0,1 m for the length of dimension BC. 4.5 Plug gauge Figure 2 and Table 3 show the plug gauge and its dimensions. The plug gauge shall have the required dimensions as specified in IEC 61754-5. Figure 2 Plug gauge for guide pin holes IEC 0,0
44、00 5ABABB BC B IEC 0,000 5 ABABB BC U DCW 0,001 W BS EN 61300-3-51:2014IEC 61300-3-51:2014 IEC 2014 9 Table 3 Dimensions for plug gauge for guide pin holes Reference Dimensions mm Remarks Minimum Maximum A C D aU aBA BB BC b0,698 5 4,599 5 6,3 2,4 0,2 0,2 6,0 0,699 0 4,600 5 6,5 2,5 0,4 0,5 6,5 For
45、two pins aTypical dimensions. bSurface roughness Rz= 0,1 m for the length of dimension BC. 4.6 Weight The weight to be used depends on the test to be carried out. The weight measurement is used for pass/fail tests including final inspection. 4.7 Tensile testing machine The tensile testing machine sh
46、all be able to record (and/or hold) the maximum value during the measurement. The tensile testing machine measurement is used for design verification testing. 5 Procedure 5.1 Method A: Method using the weight (Figure 3) The following steps shall be taken: a) Prepare the device under test (DUT) accor
47、ding to the manufacturers instructions and check the appearance in accordance with IEC 61300-3-1. b) Place the DUT in the fixture. c) Place the pin gauge or the plug gauge in the chuck. d) Insert the pin gauge or the plug gauge into the guide pin hole(s) of the connector by more than 5,5 mm. e) Fix
48、the weight to the chuck. Adjust the total weight of the jig and the weight to the specified value. f) Apply the weight slowly. Be sure that the force is applied along the axis of the guide pin hole(s). g) Wait for the specified duration. Record if the pin gauge or the plug gauge is withdrawn by the
49、specified force. Unless otherwise specified, the maximum duration shall be 15 s. BS EN 61300-3-51:2014 10 IEC 61300-3-51:2014 IEC 2014 Figure 3a Measurement for single hole Figure 3b Measurement for two holes Figure 3 Method A for examination of pin gauge/plug gauge withdrawal force (method using the weight) 5.2 Method B: Method using the tensile testing machine (Figure 4) The following steps shall be ta