1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationPassive RF and microwave devices, intermodulation level measurementPart 2: Measurement of passive intermodulation in coaxial cable assembliesBS EN 62037-2:2013National forewordTh
2、is British Standard is the UK implementation of EN 62037-2:2013. It is identical to IEC 62037-2:2012. Together with BS EN 62037-1:2012, BS EN 62037-3:2012, BS EN 62037-4:2012, BS EN 62037-5:2013 and BS EN 62037-6:2013, it supersedes BS EN 62037:2000, which will be withdrawn on 15 July 2015.The UK pa
3、rticipation in its preparation was entrusted to Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this committee can be obtained on request to its secretary.This publication doe
4、s not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013.ISBN 978 0 580 58417 6 ICS 33.120.30Compliance with a British Standard cannot confer immunity from le
5、gal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2013.Amendments issued since publicationDate Text affectedBRITISH STANDARDBS EN 62037-2:2013EUROPEAN STANDARD EN 62037-2 NORME EUROPENNE EUROPISCHE NORM March 2013CENELE
6、C European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide
7、for CENELEC members. Ref. No. EN 62037-2:2013 E ICS 33.040.20; 33.120.10 Supersedes EN 62037:1999 (partially) English version Passive RF and microwave devices, intermodulation level measurement - Part 2: Measurement of passive intermodulation in coaxial cable assemblies (IEC 62037-2:2012) Dispositif
8、s RF et micro-ondes passifs, mesure du niveau dintermodulation - Partie 2: Mesure de lintermodulation passive dans les cordons coaxiaux (CEI 62037-2:2012) Passive HF- und Mikrowellenbauteile, Messung des Intermodulationspegels - Teil 2: Messung der passiven Intermodulation in konfektionierten Koaxia
9、lkabeln (IEC 62037-2:2012) This European Standard was approved by CENELEC on 2012-12-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date
10、 lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translati
11、on under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denma
12、rk, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 62037
13、-2:2013EN 62037-2:2013 Foreword The text of document 46/408/FDIS, future edition 1 of IEC 62037-2, prepared by IEC/TC 46 “Cables,wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories“ wassubmitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 6203
14、7-2:2013. The following dates are fixed: latest date by which the document has to be implemented at national level bypublication of an identical national standard or by endorsement (dop) 2013-09-12 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2
15、015-12-12 This document partially supersedes EN 62037:1999. Attention is drawn to the possibility that some of the elements of this document may be the subject ofpatent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patentrights. Endorsement notice The text
16、of the International Standard IEC 62037-2:2012 was approved by CENELEC as a EuropeanStandard without any modification. BS EN 62037-2:2013EN 62037-2:2013 Annex ZA (normative) Normative references to international publicationswith their corresponding European publications The following documents, in w
17、hole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undatedreferences, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publicatio
18、n has been modified by common modifications, indicated by (mod), the relevant EN/HDapplies. Year Publication EN/HD Title Year IEC 62037-1 2012 Passive RF and microwave devices, intermodulation level measurement - Part 1: General requirements and measuringmethods EN 62037-1 2012 BS EN 62037-2:2013620
19、37-2 IEC:2012(E) CONTENTS 1 Scope . . 5 2 Normative references . . 5 3 Abbreviations 5 4 Test set-up . 5 5 Procedure . 7 6 Report . 7 Figure 1 PIM test set-up example . 6 Figure 2 Rotation of cable 6 Table 1 Minimum requirement of cable parameters . . 7 BS EN 62037-2:201362037-2 IEC:2012(E) 5 PASSIV
20、E RF AND MICROWAVE DEVICES, INTERMODULATION LEVEL MEASUREMENT Part 2: Measurement of passive intermodulation in coaxial cable assemblies 1 Scope This part of IEC 62037 defines a procedure to measure levels of passive intermodulation generated by a coaxial cable assembly. This test method is applicab
21、le to jumper cables, i.e. cable assemblies intended to provide interface flexibility between rigid devices. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the editi
22、on cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 62037-1:2012, Passive RF and microwave devices, intermodulation level measurement Part 1: General requirements and measuring methods 3 Abbreviations DUT Device under test P
23、IM Passive intermodulation 4 Test set-up Set-up 1 and set-up 2 are applicable in this PIM-test. Either set-up 1 (reverse method, see 6.2.2 of IEC 62037-1:2012), or set-up 2 (forward method, see 6.2.3 of IEC 62037-1:2012), may be used for cable assemblies, provided that the attenuation of the assembl
24、y is not greater than 1 dB. For higher attenuation, the reverse method shall be used. The connector under test should be clamped and mechanically secured to prevent its movement during the test. A describable and repeatable mechanical stress is applied to the DUT. This mechanical stress is defined b
25、y a distance d, between the end of the cable-entry (the last rigid mechanical point of the connector) and the point of the deflection, and circular movement around the cable axis with a radius r. This test shall be performed on each end independently. An example of a test set-up is shown in Figure 1
26、. The cable movement is depicted in Figure 2. The rotational radius (r) and distance (d) is defined in Table 1. The cable attachment to the termination should be supported. BS EN 62037-2:2013 6 62037-2 IEC:2012(E) 1 2 3 4 1 2 3 4 d r IEC 2121/12 Key 1 PIM test set-up 3 termination 2 moving unit 4 DU
27、T The distance, d and the radius, r are related to the nominal outside diameter, of the cable. Figure 1 PIM test set-up example 1 2 3 IEC 2122/12 Key 1 cable DUT 2 circular movement of cable 3 radius of deflection, r Figure 2 Rotation of cable BS EN 62037-2:201362037-2 IEC:2012(E) 7 Table 1 Minimum
28、requirement of cable parameters Cable d (see Figure 1) r (radius) Braided and foil wrapped cables 6 cable +10 mm Foam dielectric/helical and annular corrugation / 16 mm * +10 mm Air dielectric/helical corrugation 12 cable +10 mm Other cable constructions * * * to be defined between customer and supp
29、lier, or as specified by the manufacturer. Other values may be used as specified by the customer and supplier or by the manufacturer. The movement of the cable shall be carried out with a minimum of 3 cycles and a rate of (5 2) s per revolution. Torsion shall not be applied to the cable. It is recom
30、mended to rotate the cable clockwise. 5 Procedure The procedure is as follows: a) calibrate the set-up; b) connect the DUT to the set-up; c) read the PIM before applying mechanical stress; d) apply mechanical stress to the DUT according to Table 1; e) read the maximum PIM level while applying mechan
31、ical stress to the DUT; NOTE If using a spectrum analyser, it is helpful to use the “max-hold” function. f) stop the mechanical stress; g) read the PIM level after applying mechanical stress. 6 Report The report should include the following: a) radius; b) distance from the PIM tester; c) PIM levels
32、during rotation; d) PIM levels after rotation. _ BS EN 62037-2:2013This page deliberately left blankThis page deliberately left blankBSI is the independent national body responsible for preparing British Standards and other standards-related publications, information and services. It presents the UK
33、 view on standards in Europe and at the international level. BSI is incorporated by Royal Charter. British Standards and other standardisation products are published by BSI Standards Limited.British Standards Institution (BSI)raising standards worldwideBSI389 Chiswick High Road London W4 4AL UKTel +
34、44 (0)20 8996 9001Fax +44 (0)20 8996 Standards and PASs are periodically updated by amendment or revision. Users of British Standards and PASs should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and services. We w
35、ould be grateful if anyone finding an inaccuracy or ambiguity while using British Standards would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside frontcover. Similary for PASs, please notify BSI Customer Services.Tel: +44 (0)20 8996 9001
36、Fax: +44 (0)20 8996 7001BSI offers BSI Subscribing Members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of British Standards and PASs.Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001Email: Buying standardsYou may buy PDF and har
37、d copy versions of standards directly using acredit card from the BSI Shop on the website addition all orders for BSI, international and foreign standards publicationscan be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: In response to orders for internat
38、ional standards, BSI will supply the British Standard implementation of the relevant international standard, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, Europeanand international standards through its Knowledge Centre.Tel: +44 (0)20 8996 7
39、004 Fax: +44 (0)20 8996 7005Email: BSI Subscribing Members are kept up to date with standards developments and receive substantial discounts on the purchase priceof standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001
40、 Email: Information regarding online access to British Standards and PASs via British Standards Online can be found at information about British Standards is available on the BSI website at www.bsi- the data, software and documentation set out in all British Standards and other BSI publications ar
41、e the property of and copyrighted by BSI, or some person or entity that own copyright in the information used (such as the international standardisation bodies) has formally licensed such information to BSI for commerical publication and use. Except as permitted under the Copyright, Designs and Pate
42、nts Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary
43、 details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Details and advice can be obtained from the Copyright & Licensing Department.Tel: +44 (0)20 8996 7070Email: