ETSI TS 100 783-2004 Transmission and Multiplexing (TM) Passive optical components Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor and outdo.pdf

上传人:cleanass300 文档编号:737524 上传时间:2019-01-12 格式:PDF 页数:15 大小:54.41KB
下载 相关 举报
ETSI TS 100 783-2004 Transmission and Multiplexing (TM) Passive optical components Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor and outdo.pdf_第1页
第1页 / 共15页
ETSI TS 100 783-2004 Transmission and Multiplexing (TM) Passive optical components Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor and outdo.pdf_第2页
第2页 / 共15页
ETSI TS 100 783-2004 Transmission and Multiplexing (TM) Passive optical components Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor and outdo.pdf_第3页
第3页 / 共15页
ETSI TS 100 783-2004 Transmission and Multiplexing (TM) Passive optical components Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor and outdo.pdf_第4页
第4页 / 共15页
ETSI TS 100 783-2004 Transmission and Multiplexing (TM) Passive optical components Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor and outdo.pdf_第5页
第5页 / 共15页
点击查看更多>>
资源描述

1、 ETSI TS 100 783 V1.2.1 (2004-08)Technical Specification Transmission and Multiplexing (TM);Passive optical components;Fibre optic fusion splices forsingle-mode optical fibre transmission systems forindoor and outdoor applications;Common requirements and conformance testingETSI ETSI TS 100 783 V1.2.

2、1 (2004-08) 2 Reference RTS/TM-01111 Keywords connector, fibre, optical, performance, transmission ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-

3、Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between suc

4、h versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subjec

5、t to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_

6、support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2004. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trad

7、e Marks of ETSI registered for the benefit of its Members. TIPHONTMand the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI TS 100

8、 783 V1.2.1 (2004-08) 3 Contents Intellectual Property Rights4 Foreword.4 1 Scope 5 2 References 5 3 Definition and abbreviations 6 3.1 Definition .6 3.2 Abbreviations .6 4 Details, measurements and performance requirements6 4.1 Visual inspection 6 4.2 Attenuation.6 4.3 Return Loss (RL)7 4.4 Vibrati

9、on (sinusoidal).7 4.5 Fibre retention 7 4.6 Torsion .8 4.7 Drop test (Impact method A)8 4.8 Cold8 4.9 Dry heat9 4.10 Damp heat (steady state) 9 4.11 Damp heat (cyclic) .10 4.12 Change of temperature .10 4.13 Corrosive atmosphere (salt mist)11 4.14 Industrial atmosphere .11 4.15 Condensation12 4.16 W

10、ater immersion 12 5 Acceptance criteria.13 5.1 Minimum sample size for qualification13 5.1.1 Qualification to minimum uniform requirements .13 5.1.2 Qualification for EN 300 019 environment classes 3.3, 3.4 and 3.5.13 5.1.3 Qualification for EN 300 019 environment class 4.113 5.2 Attenuation.14 5.3

11、Pass/fail criteria 14 History 15 ETSI ETSI TS 100 783 V1.2.1 (2004-08) 4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and

12、 non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/

13、IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to t

14、he present document. Foreword This Technical Specification (TS) has been produced by ETSI Technical Committee Transmission and Multiplexing (TM). The present document is a revision of I-ETS 300 783. ETSI ETSI TS 100 783 V1.2.1 (2004-08) 5 1 Scope The present document specifies requirements for fusio

15、n splices to be used in single mode optical fibre telecommunications land-based (not submarine) systems. The scope covers the establishment of minimum uniform requirements for the following aspects: - optical, environmental and mechanical properties; - test conditions; - acceptance criteria. The spl

16、ices are considered to be between single fibres, between ribbon fibres and between ribbon and multiple fibres. The optical fibres which are spliced are intended to conform to IEC 60793-2-50 4. These requirements cover splices with the same single mode fibre type. In order to obtain the required func

17、tional behaviour of the fusion splices, it is necessary to follow a number of procedures for fibre preparation, fibre alignment, jointing and protection as described in ITU-T Recommendation L.12 3. All the following requirements refer to protected splices measured in a laboratory. This ES is intende

18、d to provide criteria for the assessment of splicing equipment and techniques, including the splice protector. Some users may have additional specific requirements, such as the need to verify performance at lower temperatures. These users should specify splices conforming to the basic ETSI performan

19、ce standard plus the additional tests or more severe test conditions. 2 References The following documents contain provisions which, through reference in this text, constitute provisions of the present document. References are either specific (identified by date of publication and/or edition number

20、or version number) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. 1 E

21、TSI EN 300 019 (all parts): “Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment“. 2 IEC 61300 (all parts): “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures“. 3 ITU-T Recommendation L.12: “Op

22、tical fibre joints“. 4 ETSI I-ETS 300 783: “Transmission and Multiplexing (TM); Passive optical components; Fibre optic fusion splices for single-mode optical fibre transmission systems; Common requirements and conformance testing“. ETSI ETSI TS 100 783 V1.2.1 (2004-08) 6 3 Definition and abbreviati

23、ons 3.1 Definition For the purposes of the present document, the following terms and definitions apply: fusion splice: fusion spliced fibres protected by a splice protector with fibre tails of 1,5 metres on each side of the splice protector 3.2 Abbreviations For the purposes of the present document,

24、 the following abbreviations apply: RL Return Loss 4 Details, measurements and performance requirements The performance requirements shall fulfil the ETSI environmental classes 3.1, 3.2 , 3.3 as well as environmental category U from IEC 61753-1. All measurements shall be carried out under normal roo

25、m conditions, unless otherwise stated. Before the insertion and return loss measurement, careful cleaning in accordance with manufacturers instructions is necessary. All optical tests shall be carried out in both the 1 310 nm window and the 1 550 nm window unless otherwise stated. Light sources with

26、 peak wavelengths of 1 310 30 nm and 1 550 30 nm shall be used. The length of fibre or cable on each side of the connector set shall be 1,5 m (minimum). A minimum length of 1,5 m on each side of the test set shall be exposed to the test conditions of all climatic and environmental tests. 4.1 Visual

27、inspection Details In accordance with IEC 61300-3-1 2. The splice shall be examined for defects using a magnifying glass giving a magnification of between 3 and 8 times. Requirements The fused region and the stripped fibre on each side of the fused region shall be fully enclosed within the splice pr

28、otector. The splice protector shall be seen to be gripping the fibre coating at each end of the splice. The fibre shall emerge from the protector without any visible sign of bending or kinking. The splice protector shall show no sign of damage. Heat shrink splice protectors shall have no bulges sinc

29、e these would suggest that air had become trapped during the shrink down process. 4.2 Attenuation Details In accordance with IEC 61300-3-4 2. Requirements The requirements specified in the following table apply to both the 1 310 nm and 1 550 nm windows. ETSI ETSI TS 100 783 V1.2.1 (2004-08) 7 Table

30、1 Category Mean attenuation Maximum attenuation Single fibres: Class I 0,08 dB 0,15 dB Class II 0,20 dB 0,50 dB Ribbon and multiple fibres: Class III 0,20 dB 0,80 dB 4.3 Return Loss (RL) Details In accordance with IEC 61300-3-6 2. Requirements allowable return loss: 60 dB. Throughout all the environ

31、mental and climatic tests, the return loss shall be 60 dB. 4.4 Vibration (sinusoidal) Details In accordance with IEC 61300-2-1 (Second edition - 2003-01) 2: frequency range: 10 Hz to 55 Hz; endurance duration per axis: 0,5 hour; number of axes: three, orthogonal; number of cycles (10-55-10): 15; vib

32、ration amplitude: 0,75 mm. Requirements During the test the attenuation shall be within 0,10 dB of the initial value. On completion of the test there shall be no difference between the initial and final attenuation. The attenuation shall be measured at 1 310 nm 30 nm and 1 550 nm 30 nm before, durin

33、g and after the test. The maximum sampling interval during the test shall be 2 ms. 4.5 Fibre retention Details In accordance with IEC 61300-2-4 2: magnitude and rate of application of the tensile load: 5 0,5 N applied at 0,5 N/s; duration of the test (maintaining the load): 60 s; point of applicatio

34、n of the tensile load: 0,3 m from the splice. ETSI ETSI TS 100 783 V1.2.1 (2004-08) 8 Requirements During the test the attenuation shall be within 0,10 dB of the initial value. On completion of the test there shall be no difference between the initial and final attenuation. The attenuation shall be

35、measured at 1 310 nm 30 nm and 1 550 nm 30 nm before, during and after the test. During the test the attenuation shall be measured at least once while the load is at the maximum level. 4.6 Torsion Details In accordance with IEC 61300-2-5 2: magnitude of tensile load 2 N; point of application of the

36、tensile load: 0,3 m from the splice; maximum torsion angle 180; duration of the test: 50 cycles (not to exceed the fibre specification). Requirements During the test the attenuation variation shall be 0,20 dB. On completion of the test the difference between the final and the initial attenuation sha

37、ll be 0,10 dB. The return loss during and on completion of the test shall not fall below the minimum for the grade. The attenuation and the return loss shall be measured at 1 310 nm 30 nm and 1 550 nm 30 nm before, during and after the test. During the test the attenuation and return loss shall be m

38、easured at least once every time when the torsion angle is at the maximum value. 4.7 Drop test (Impact method A) Details In accordance with IEC 61300-2-12 method A (drop test) 2: number of drops: 5; Drop height: 1,5 m. Requirements On completion of the test the difference between the initial and the

39、 final attenuation shall be 0,10 dB and the return loss shall not fall below the minimum for the grade. The measurements shall be carried out at 1 310 nm 30 nm and 1 550 nm 30 nm. 4.8 Cold Details In accordance with IEC 61300-2-17 2: temperature: -25C;duration of exposure: 96 hours; pre-conditioning

40、 procedure: 2 hours at normal ambient conditions; recovery procedure: 2 hours at normal ambient conditions. ETSI ETSI TS 100 783 V1.2.1 (2004-08) 9 Requirements During the test the attenuation shall be within 0,10 dB of the initial value. On completion of the test there shall be no difference betwee

41、n the initial and final attenuation. The attenuation shall be measured at 1 310 nm 30 nm and 1 550 nm 30 nm before, during and after the test. During the test the attenuation shall be measured at a maximum interval of 1 hour. 4.9 Dry heat Details In accordance with IEC 61300-2-18 2: temperature: +70

42、C; duration of exposure: 96 hours; pre-conditioning procedure: 2 hours at normal ambient conditions; recovery procedure: 2 hours at normal ambient conditions. Requirements During the test the attenuation shall be within 0,10 dB of the initial value. On completion of the test there shall be no differ

43、ence between the initial and final attenuation. The attenuation shall be measured at 1 310 nm 30 nm and 1 550 nm 30 nm before, during and after the test. During the test the attenuation shall be measured at a maximum interval of 1 hour. 4.10 Damp heat (steady state) Details In accordance with IEC 61

44、300-2-19 2: temperature: +40C; relative humidity: 93 2 %; duration of exposure: 96 hours; pre-conditioning procedure: 2 hours at normal ambient conditions; recovery procedure: 2 hours at normal ambient conditions. Requirements During the test the attenuation shall be within 0,10 dB of the initial va

45、lue. On completion of the test there shall be no difference between the initial and final attenuation. The attenuation shall be measured at 1 310 nm 30 nm and 1 550 nm 30 nm before, during and after the test. During the test the attenuation shall be measured at a maximum interval of 1 hour. ETSI ETS

46、I TS 100 783 V1.2.1 (2004-08) 104.11 Damp heat (cyclic) Details This test shall be carried out on splices which are to be used in weather protected environments corresponding to EN 300 019 1, classes 3.3, 3.4 or 3.5 or 3.5 or in non-weather protected environments corresponding to EN 300 019 1 class

47、4.1. This test should be carried out in accordance with IEC 61300-2-46 2: high temperature: +55C; low temperature: +25C; duration of each cycle: 24 hours; number of cycles: 6; pre-conditioning procedure: 2 hours at normal ambient conditions; recovery procedure: 16 hours at normal ambient conditions.

48、 Requirements During the test the attenuation shall be within 0,10 dB of the initial value. On completion of the test there shall be no difference between the initial and final attenuation. The attenuation shall be measured at 1 310 nm 30 nm and 1 550 nm 30 nm before, during and after the test. Duri

49、ng the test the attenuation shall be measured at a maximum interval of 1 hour. 4.12 Change of temperature Details In accordance with IEC 61300-2-22 2: high temperature: +70C; low temperature: -25C; duration at extreme temperatures: 1 hour; rate of change of temperature: 1C/minute; number of cycles: 12; pre-conditioning procedure: 2 hours at normal ambient conditions; recovery procedure: 2 hours at normal ambient conditions. Requirements During the test