ETSI TS 119 124-3-2016 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures - Testing Conformance and Interoperability Part 3 Test suites for testing interopera.pdf

上传人:sofeeling205 文档编号:740270 上传时间:2019-01-11 格式:PDF 页数:27 大小:134.81KB
下载 相关 举报
ETSI TS 119 124-3-2016 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures - Testing Conformance and Interoperability Part 3 Test suites for testing interopera.pdf_第1页
第1页 / 共27页
ETSI TS 119 124-3-2016 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures - Testing Conformance and Interoperability Part 3 Test suites for testing interopera.pdf_第2页
第2页 / 共27页
ETSI TS 119 124-3-2016 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures - Testing Conformance and Interoperability Part 3 Test suites for testing interopera.pdf_第3页
第3页 / 共27页
ETSI TS 119 124-3-2016 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures - Testing Conformance and Interoperability Part 3 Test suites for testing interopera.pdf_第4页
第4页 / 共27页
ETSI TS 119 124-3-2016 Electronic Signatures and Infrastructures (ESI) CAdES digital signatures - Testing Conformance and Interoperability Part 3 Test suites for testing interopera.pdf_第5页
第5页 / 共27页
点击查看更多>>
资源描述

1、 ETSI TS 119 124-3 V1.1.1 (2016-06) Electronic Signatures and Infrastructures (ESI); CAdES digital signatures - Testing Conformance and Interoperability; Part 3: Test suites for testing interoperability of extended CAdES signatures TECHNICAL SPECIFICATION ETSI ETSI TS 119 124-3 V1.1.1 (2016-06)2 Ref

2、erence DTS/ESI-0019124-3 Keywords CAdES, e-commerce, electronic signature, interoperability, profile, security, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucrati

3、f enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice The present document can be downloaded from: http:/www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the pres

4、ent document shall not be modified without the prior written authorization of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network dr

5、ive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at https:/portal.etsi.org/TB/ETSIDeliverableStatus.aspx If you find errors in t

6、he present document, please send your comment to one of the following services: https:/portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as a

7、uthorized by written permission of ETSI. The content of the PDF version shall not be modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2016. All rights reserved. DECTTM,

8、 PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Asso

9、ciation. ETSI ETSI TS 119 124-3 V1.1.1 (2016-06)3 Contents Intellectual Property Rights 4g3Foreword . 4g3Modal verbs terminology 4g31 Scope 5g32 References 5g32.1 Normative references . 5g32.2 Informative references 5g33 Definitions and abbreviations . 6g33.1 Definitions 6g33.2 Abbreviations . 6g34

10、Overview 6g35 Testing extended CAdES signatures interoperability . 7g35.1 CAdES-E-BES test cases . 7g35.2 CAdES-E-EPES test cases . 8g35.3 CAdES-E-T test cases 9g35.4 CAdES-E-C test cases 9g35.5 CAdES-E-X test cases 11g35.6 CAdES-E-XL test cases . 12g35.7 CAdES-E-A test cases 14g36 Testing extended

11、CAdES signatures augmention interoperability . 18g36.1 Introduction 18g36.2 Augmentation to CAdES-E-C signatures test cases . 18g36.3 Augmentation to CAdES-E-X signatures test cases . 19g36.4 Augmentation to CAdES-E-XL signatures test cases 20g36.5 Augmentation to CAdES-E-A signatures test cases . 2

12、1g37 Testing negative extended CAdES signatures 22g37.1 CAdES-E-BES test cases . 22g37.2 CAdES-E-EPES test cases . 23g37.3 CAdES-E-T test cases 23g37.4 CAdES-E-A test cases 25g3History 27g3ETSI ETSI TS 119 124-3 V1.1.1 (2016-06)4 Intellectual Property Rights IPRs essential or potentially essential t

13、o the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to

14、ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (https:/ipr.etsi.org/). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the e

15、xistence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been produced by ETSI Technical Committee Electronic Signatures and Infrastructures

16、(ESI). The present document is part 3 of a multi-part deliverable covering CAdES digital signatures - Testing Conformance and Interoperability. Full details of the entire series can be found in part 1 i.1. Modal verbs terminology In the present document “shall“, “shall not“, “should“, “should not“,

17、“may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. ETSI ETSI TS 119 124-

18、3 V1.1.1 (2016-06)5 1 Scope The present document defines a number of test suites to assess the interoperability between implementations claiming conformance to extended CAdES signatures 2. The present document defines test suites for each level defined in ETSI EN 319 122-2 2. Test suites also cover

19、augmentation of extended CAdES signatures and negative test cases. These test suites are agnostic of the PKI infrastructure. Any PKI infrastructure can be used including the one based on EU Member States Trusted Lists. 2 References 2.1 Normative references References are either specific (identified

20、by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. Referenced documents which are not found to be publ

21、icly available in the expected location might be found at https:/docbox.etsi.org/Reference/. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced documents are necessary for the application

22、of the present document. 1 ETSI EN 319 122-1: “Electronic Signatures and Infrastructures (ESI); CAdES digital signatures; Part 1: Building blocks and CAdES baseline signatures“. 2 ETSI EN 319 122-2: “Electronic Signatures and Infrastructures (ESI); CAdES digital signatures; Part 2: Extended CAdES si

23、gnatures“. 2.2 Informative references References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (inclu

24、ding any amendments) applies. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following referenced documents are not necessary for the application of the present document but they assist the user with regar

25、d to a particular subject area. i.1 ETSI TR 119 124-1: “Electronic Signatures and Infrastructures (ESI); CAdES digital signatures - Testing Conformance and Interoperability; Part 1: Overview“. i.2 ETSI TR 119 001: “Electronic Signatures and Infrastructures (ESI); The framework for standardization of

26、 signatures; Definitions and abbreviations“. i.3 ETSI EN 319 102-1: “Electronic Signatures and Infrastructures (ESI); Procedures for Creation and Validation of AdES Digital Signatures; Part 1: Creation and Validation“. i.4 IETF RFC 3125 (09-2001): “Electronic Signature Policies“. ETSI ETSI TS 119 12

27、4-3 V1.1.1 (2016-06)6 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the terms and definitions given in ETSI TR 119 001 i.2 and the following apply: negative test case: test case for a signature whose validation according to ETSI EN 319 102-1 i.3 would not

28、result in TOTAL-PASSED 3.2 Abbreviations For the purposes of the present document, the abbreviations given in ETSI TR 119 001 i.2 apply. 4 Overview This clause describes the overall approach used to specify test suites for extended CAdES signatures interoperability testing. ETSI EN 319 122-2 2 defin

29、es different signature levels. The test suites are defined with different layers reflecting the levels of extended CAdES signatures specified in 2. Testing CAdES signatures: CAdES-E-BES signatures test cases; CAdES-E-EPES signatures test cases; CAdES-E-T signatures test cases; CAdES-E-C test cases;

30、CAdES-E-X test cases; CAdES-E-X Long test cases; CAdES-E-A signatures (with ATSv2 and ATSv3) built on CAdES-E-T signatures test cases. Testing negative CAdES signatures: CAdES-E-BES test cases; CAdES-E-EPES test cases; CAdES-E-T test cases; CAdES-E-A test cases. Testing augmentation of CAdES signatu

31、res: augmentation to CAdES-E-C levels test cases; augmentation to CAdES-E-X levels test cases; augmentation to CAdES-E-XL levels test cases; augmentation to CAdES-E-A levels test cases. ETSI ETSI TS 119 124-3 V1.1.1 (2016-06)7 5 Testing extended CAdES signatures interoperability 5.1 CAdES-E-BES test

32、 cases The test cases in this clause have been defined for different combinations of CAdES-E-BES signatures attributes. Mandatory attributes for CAdES-E-BES described in 2 specification, clauses 4.2 and 4.3, shall be present. Table 1 shows which attributes are required to generate CAdES-E-BES signat

33、ures for each test case. Table 1: Test cases for CAdES-E-BES signatures TC ID Description Pass criteria Signature attributes CAdES/BES/1 This is the simplest CAdES-E-BES signature without signing time. The signature ONLY CONTAINS the mandatory CAdES attributes. Positive validation. The signature sha

34、ll contain ContentType, MessageDigest, SigningCertificate (included in SignedData.certificates field) and ESSSigningCertificateV2 attributes. Certificates o SigningCertificate SignedAttributes o MessageDigest o ESSSigningCertificateV2 o ContentType CAdES/BES/2 This is the simplest CAdES-E-BES signat

35、ure with signing time. The signature ONLY CONTAINS a signing time attribute in addition to all the mandatory CAdES attributes. Positive validation. The signature shall contain ContentType, SigningTime, MessageDigest, SigningCertificate (included in SignedData.certificates field) and ESSSigningCertif

36、icateV2 attributes. Certificates o SigningCertificate SignedAttributes o MessageDigest o ESSSigningCertificateV2 o ContentType o SigningTime CAdES/BES/3 In this CAdES-E-BES signature test case the signature contains a CertifiedAttributeV2 in addition to the CAdES/BES/2 test case attributes. Positive

37、 validation. The signature shall contain ContentType, SigningTime, MessageDigest, SigningCertificate (included in SignedData.certificates field), ESSSigningCertificateV2 and CertifiedAttributeV2 attributes. Certificates o SigningCertificate SignedAttributes o MessageDigest o ESSSigningCertificateV2

38、o ContentType o SigningTime o SignerAttributesV2 (CertifiedAttributeV2) CAdES/BES/4 This test case tests a CAdES-E-BES signature with ContentTimeStamp attribute. Positive validation. The signature shall contain ContentType, SigningTime, MessageDigest, SigningCertificate (included in SignedData.certi

39、ficates field), ESSSigningCertificateV2 and ContentTimeStamp attributes. Certificates o SigningCertificate SignedAttributes o MessageDigest o ESSSigningCertificateV2 o ContentType o SigningTime o ContentTimeStamp CAdES/BES/5 This test case tests a CAdES-E-BES signature with CounterSignature attribut

40、e. The input to this test is a CAdES-E-BES signature as specified in CAdES/BES/2 test case. Positive validation. The signature shall contain ContentType, SigningTime, MessageDigest, SigningCertificate (included in SignedData.certificates field), ESSSigningCertificateV2 and CounterSignature attribute

41、s. Certificates o SigningCertificate SignedAttributes o MessageDigest o ESSSigningCertificateV2 o ContentType o SigningTime UnsignedAttributes o CounterSignature CAdES/BES/6 This test case tests a CAdES-E-BES signature with multiple independent signatures. The input to this test is a CAdES-E-BES sig

42、nature as specified in CAdES/BES/2 test case. Positive validation. The signature shall contain 2 SigningCertificates (included in SignedData.certificates field) attributes and 2 signerInfos containing ContentType, SigningTime, MessageDigest and ESSSigningCertificateV2 attributes. Certificates o Sign

43、ingCertificate SignedAttributes o MessageDigest o ESSSigningCertificateV2 o ContentType o SigningTime ETSI ETSI TS 119 124-3 V1.1.1 (2016-06)8 TC ID Description Pass criteria Signature attributes CAdES/BES/7 This test case tests a CAdES-E-BES signature with the following attributes at once: - Messag

44、eDigest - SigningTime - ESSSigningCertificateV2 - SignerLocation - SignerAttributesV2 (only Claimed Attributes included) - ContentType - ContentHints - ContentIdentifier - CommitmentTypeIndication. Positive validation. The signature shall contain the following attributes: SigningCertificate (include

45、d in SignedData.certificates field), MessageDigest, SigningTime, ESSSigningCertificateV2, SignerLocation, SignerAttributesV2 (only Claimed Attributes included), ContentType, ContentHints, ContentIdentifier, CommitmentTypeIndication. Certificates o SigningCertificate SignedAttributes o MessageDigest

46、o ESSSigningCertificateV2 o ContentType o SigningTime o SignerLocation o SignerAttributesV2 (ClaimedAttribute) o ContentHints o ContentIdentifier o CommitmentTypeIndication o ContentTimeStamp 5.2 CAdES-E-EPES test cases The test cases in this clause have been defined for different combinations of CA

47、dES-E-EPES signatures attributes. Mandatory attributes for CAdES-E-EPES described in 2 specification, clauses 4.2 and 4.3, shall be present. Table 2 shows which attributes are required to generate CAdES-E-EPES signatures for each test case. Table 2: Test cases for CAdES-E-EPES signatures TC ID Descr

48、iption Pass criteria Signature attributes CAdES/EPES/1 This is the simplest CAdES-E-EPES signature. The signature ONLY CONTAINS the mandatory CAdES attributes. Positive validation. The signature shall contain ContentType, SigningTime, MessageDigest, SigningCertificate (included in SignedData.certifi

49、cates field), ESSSigningCertificateV2, SignaturePolicyIdentifier attributes. Certificates o SigningCertificate SignedAttributes o MessageDigest o ESSSigningCertificateV2 o ContentType o SigningTime o SignaturePolicyIdentifier CAdES/EPES/2 In this CAdES-E-EPES signature test case the signature-policy-identifier attribute is qualified with additional information within sigPolicyQualifiers. The sigPolicyQualifiers shall include the oid of sp-user-notice (1.2.840.113549.1.9.16.5.2) and

展开阅读全文
相关资源
猜你喜欢
  • ASD-STAN PREN 2591-C14-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C14 - Immersion at Low Air Pressure (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第.pdf ASD-STAN PREN 2591-C14-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C14 - Immersion at Low Air Pressure (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第.pdf
  • ASD-STAN PREN 2591-C15-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C15 - Fluid Resistance (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C15部分 耐流体性 第P.pdf ASD-STAN PREN 2591-C15-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C15 - Fluid Resistance (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C15部分 耐流体性 第P.pdf
  • ASD-STAN PREN 2591-C16-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C16 - Ozone Resistance (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C16部分 抗臭氧性 第P.pdf ASD-STAN PREN 2591-C16-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C16 - Ozone Resistance (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C16部分 抗臭氧性 第P.pdf
  • ASD-STAN PREN 2591-C17-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C17 - Flammability (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C16部分 易燃性 第P1版》.pdf ASD-STAN PREN 2591-C17-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C17 - Flammability (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C16部分 易燃性 第P1版》.pdf
  • ASD-STAN PREN 2591-C18-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C18 - Fire-Resistance (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C18部分 耐火性 第P1版.pdf ASD-STAN PREN 2591-C18-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C18 - Fire-Resistance (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C18部分 耐火性 第P1版.pdf
  • ASD-STAN PREN 2591-C19-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C19 - Gas-Tightness of Solderless Wrapped Connections (Issue P 1)《航空航天系.pdf ASD-STAN PREN 2591-C19-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C19 - Gas-Tightness of Solderless Wrapped Connections (Issue P 1)《航空航天系.pdf
  • ASD-STAN PREN 2591-C2-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C2 - Climatic Sequence (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C2部分 气候顺序 第P1版.pdf ASD-STAN PREN 2591-C2-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C2 - Climatic Sequence (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C2部分 气候顺序 第P1版.pdf
  • ASD-STAN PREN 2591-C20-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C20 - Simulated Solar Radiation at Ground Level (Issue P 1)《航空航天系列 电气和光.pdf ASD-STAN PREN 2591-C20-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C20 - Simulated Solar Radiation at Ground Level (Issue P 1)《航空航天系列 电气和光.pdf
  • ASD-STAN PREN 2591-C21-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C21 - Damp Heat Cyclic Test (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C21部分 湿热.pdf ASD-STAN PREN 2591-C21-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C21 - Damp Heat Cyclic Test (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C21部分 湿热.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1