1、 FORD LABORATORY TEST METHOD BO 111-02 Date Action Revisions Rev 03 2015 09 14 Editorial See Summary of Revisions L. Sinclair, NA 2015 06 29 Revised See Summary of Revisions L. Sinclair, NA 1991 02 14 Controlled document at www.MATS Copyright 2015, Ford Global Technologies, Inc. Page 1 of 2 TEST FOR

2、 INDENTATION AND RECOVERY Application This method is used to determine the recovery after indentation of soft interior composite systems. Apparatus Required Tensile Tester Universal Testing Machine, Instron or equivalent capable of compression loading. Indentor and Fixture Refer to Figure 1 Indentor

3、 Head Steel indentor of no less than 38 mm in length with a 7.5 mm spherical radius. Shown in Figure 1. Conditioning and Test Conditions All test values are based on material conditioned for not less than 24 h prior to testing in a controlled environment of 23 +/- 2 C and 50 +/- 5% relative humidity

4、 Testing of the material should occur in the conditioning environment or soon after removal to minimize the fluctuation of the specimen conditions. Procedure 1. Cut specimen 200 mm by 200 mm in size. 2. Place the sample so the area to be tested is perpendicular to the indentor head, See Figure 1. T

5、he area tested should be as flat as possible. 3. The testing machine should apply and reach the specified load (as defined in the specification) within 3 seconds. The testing machine should automatically remove the load as soon as the defined load has been achieved. 4. Remove the sample from the tes

6、ting machine and place on a flat surface. 5. Reference applicable performance specification for allowed recovery time. 6. Evaluate to determine if a full recovery has been achieved. Full recovery (a pass) is defined as no indentation observed to the unaided eye at any angle. FORD LABORATORY TEST MET

7、HOD BO 111-02 Copyright 2015, Ford Global Technologies, Inc. Page 2 of 2 Reporting The following items should be recorded in the final report. 1. Rate of speed 2. Force applied 3. Required recovery time as specification 4. Recovery Fully recovered or not fully recovered 5. Report any deviations to t

8、his method Summary of Revisions 2015 09 14 - Corrected page numbers. 2015 06 29 - Changed application to include soft interior composite systems - Updated apparatuses used updated universal testing machine, removed compression apparatus, updated photos of indentor and fixtures - updated conditioning statement - Removed procedure A for crash pads - Removed the load (information to be housed in the material specifications) - Updated procedure to use a universal tester instead of the compression technique by hand. - Added evaluation information - Added reporting section Figure 1: Test Setup.

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TR 62001-4-2016 High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Equipment《高压直流 (HVDC) 系统 交流滤波器的规格和设计.pdf BS PD IEC TR 62001-4-2016 High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Equipment《高压直流 (HVDC) 系统 交流滤波器的规格和设计.pdf
  • BS PD IEC TR 62048-2014 Optical fibres Reliability Power law theory《光纤 可靠性 功率定律理论》.pdf BS PD IEC TR 62048-2014 Optical fibres Reliability Power law theory《光纤 可靠性 功率定律理论》.pdf
  • BS PD IEC TR 62131-5-2015 Environmental conditions Vibration and shock of electrotechnical equipment Equipment during storage and handling《环境条件 电工设备的振动和冲击 存储和处理过程中的设备》.pdf BS PD IEC TR 62131-5-2015 Environmental conditions Vibration and shock of electrotechnical equipment Equipment during storage and handling《环境条件 电工设备的振动和冲击 存储和处理过程中的设备》.pdf
  • BS PD IEC TR 62271-307-2015 High-voltage switchgear and controlgear Guidance for the extension of validity of type tests of AC metal and solid-insulation enclosed switchge.pdf BS PD IEC TR 62271-307-2015 High-voltage switchgear and controlgear Guidance for the extension of validity of type tests of AC metal and solid-insulation enclosed switchge.pdf
  • BS PD IEC TR 62343-6-10-2017 Dynamic modules Design guide Intermediate controller for multiple dynamic module systems《动态模块 设计指南 多个动态模块系统的中间控制器》.pdf BS PD IEC TR 62343-6-10-2017 Dynamic modules Design guide Intermediate controller for multiple dynamic module systems《动态模块 设计指南 多个动态模块系统的中间控制器》.pdf
  • BS PD IEC TR 62343-6-4-2017 Dynamic modules Design guides Reconfigurable optical add drop multiplexer《动态模块 设计指南 可重构光分插复用器》.pdf BS PD IEC TR 62343-6-4-2017 Dynamic modules Design guides Reconfigurable optical add drop multiplexer《动态模块 设计指南 可重构光分插复用器》.pdf
  • BS PD IEC TR 62343-6-5-2014 Dynamic modules Design guide Investigation of operating mechanical shock and vibration tests for dynamic modules《动态模块 设计指南 动态模块操作机械冲击和振动试验研究》.pdf BS PD IEC TR 62343-6-5-2014 Dynamic modules Design guide Investigation of operating mechanical shock and vibration tests for dynamic modules《动态模块 设计指南 动态模块操作机械冲击和振动试验研究》.pdf
  • BS PD IEC TR 62343-6-6-2017 Dynamic modules Design guide Failure mode effect analysis for optical units of dynamic modules《动态模块 设计指南 动态模块的光学单元用故障模式效应分析》.pdf BS PD IEC TR 62343-6-6-2017 Dynamic modules Design guide Failure mode effect analysis for optical units of dynamic modules《动态模块 设计指南 动态模块的光学单元用故障模式效应分析》.pdf
  • BS PD IEC TR 62343-6-7-2015 Dynamic modules Design guide Optical channel monitor《动态模块 设计指南 光通道监测仪》.pdf BS PD IEC TR 62343-6-7-2015 Dynamic modules Design guide Optical channel monitor《动态模块 设计指南 光通道监测仪》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1