FORD FLTM BZ 104-02-2001 PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH (Replaces FLTM BZ 004-02)《橡胶涂层的隔膜布的渗透性 替代FLTM BZ 004-02[替代 FORD FLTM BZ 004-02]》.pdf

上传人:arrownail386 文档编号:747692 上传时间:2019-01-14 格式:PDF 页数:6 大小:42.21KB
下载 相关 举报
FORD FLTM BZ 104-02-2001 PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH (Replaces FLTM BZ 004-02)《橡胶涂层的隔膜布的渗透性 替代FLTM BZ 004-02[替代 FORD FLTM BZ 004-02]》.pdf_第1页
第1页 / 共6页
FORD FLTM BZ 104-02-2001 PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH (Replaces FLTM BZ 004-02)《橡胶涂层的隔膜布的渗透性 替代FLTM BZ 004-02[替代 FORD FLTM BZ 004-02]》.pdf_第2页
第2页 / 共6页
FORD FLTM BZ 104-02-2001 PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH (Replaces FLTM BZ 004-02)《橡胶涂层的隔膜布的渗透性 替代FLTM BZ 004-02[替代 FORD FLTM BZ 004-02]》.pdf_第3页
第3页 / 共6页
FORD FLTM BZ 104-02-2001 PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH (Replaces FLTM BZ 004-02)《橡胶涂层的隔膜布的渗透性 替代FLTM BZ 004-02[替代 FORD FLTM BZ 004-02]》.pdf_第4页
第4页 / 共6页
FORD FLTM BZ 104-02-2001 PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH (Replaces FLTM BZ 004-02)《橡胶涂层的隔膜布的渗透性 替代FLTM BZ 004-02[替代 FORD FLTM BZ 004-02]》.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、 FORD LABORATORY TEST METHOD BZ 104-02 Date Action Revisions 2001 04 30 Revised Editorial no technical change A. Cockman 1990 10 29 Printed copies are uncontrolled Page 1 of 6 Copyright 2001, Ford Global Technologies, Inc. PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH Application This test method desc

2、ribes the procedure for determining the resistance to permeation of molded synthetic elastomer-coated reinforced polymide diaphragm cloth by gasoline vapors. The sample is exposed to gasoline vapors and the time for permeation is measured. Apparatus and Materials Required Permeation Test Fixture Tes

3、t fixture as described in Figures 1 and 2. Sample Cutting Die or Scissors Die or scissors to cut circular samples 100 mm in diameter. Stopwatch or Elapsed Timer Gasoline Caution - Gasoline is extremely flammable. Exercise caution. No smoking or open flame permitted in area while test is being run. P

4、erform test in an area with adequate ventilation. Refer to Fire Control Bulletin No. 18. Filtered, Dry Compressed Air Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not

5、less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Prepare test sample using scissors or sample cutting die. Sample to be 100 +/- 3 mm in diameter and thickness shall be as received. 2. Pour sufficient gasoline into lower section of test fix

6、ture to fill fixture approximately 13 mm deep. FORD LABORATORY TEST METHOD BZ 104-02 Page 2 of 6 Copyright 2001, Ford Global Technologies, Inc. 3. Place sample in recess of lower section of test fixture. Position upper section on sample and position clamps. Tighten clamps firmly to obtain an adequat

7、e seal. See Figures 1, 2, and 3. 4. Pour sufficient de-aerated water into upper section of fixture to fill approximately 20 mm deep. Allow assembled test fixture with test sample in place to stand at room temperature for about 15 minutes to allow gasoline vapors to accumulate under test sample. 5. A

8、pply 103 +/- 7 kPa air pressure to lower side of diaphragm through port. Close valve to maintain pressure. Start timer or stopwatch at the time the desired pressure is reached. 6. Observe the test sample under the water. Record the elapsed time until the first bubble breaks free from the diaphragm s

9、urface. Report as required in the relevant Engineering Materials Specification. Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities. FORD LABORATORY TEST METHOD B

10、Z 104-02 Page 3 of 6 Copyright 2001, Ford Global Technologies, Inc. PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH Attachment Procedure for De-aerating Water Apparatus Required Filtering Flask - 1000 mL Stopper - No. 8 Vacuum Pump or Aspirator Vacuum Gage Rubber Tubing - Heavy wall Procedure 1. Pour ap

11、proximately 500 mL of tap or distilled water into an Erlenmeyer filtering flask. Stopper flask. 2. Attach tubing to filter tubulation and vacuum pump or aspirator. 3. Turn on pump or aspirator. Evacuate flask to at least 50 kPa for a minimum of 15 minutes. 4. Turn off pump or aspirator and use the w

12、ater as soon as possible. FORD LABORATORY TEST METHOD BZ 104-02 Page 4 of 6 Copyright 2001, Ford Global Technologies, Inc. PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH Figure 1 FORD LABORATORY TEST METHOD BZ 104-02 Page 5 of 6 Copyright 2001, Ford Global Technologies, Inc. PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH Figure 2 FORD LABORATORY TEST METHOD BZ 104-02 Page 6 of 6 Copyright 2001, Ford Global Technologies, Inc. PERMEATION OF RUBBER-COATED DIAPHRAGM CLOTH Figure 3 Test Fixture Assembly

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1