1、 61347-12011 1 IEC 61347-1:2007Lamp controlgear Part 1: General and safety requirements(IDT) 27 2002 . 184- , 1.02004 . 1 -, - . . ( ) -, 42 332 3 13 2011 . 1399-4 61347-1:2007 . 1. (IEC 61347-1:2007Lamp controlgear Part 1: General and safety requirements) 1:2010. - - , 5 , - . () . - , , 2012 , - -
2、 II 61347-120111 .12 13 34 55 56 67 .68 .89 .810 .811 912 .913 .1014 1315 .1616 .1617 , .1718 , 1819 1820 18 () , , , .19 () .20 () - 26 D () - .28 () S, 4500, tW.30 F () , 32 G () 33 () .37 I () 41 J () .43 () .43 () .4547III 61347-12011 1 Lamp controlgear. Part 1. General and safety requirements 2
3、01207011 , 250 / - 1000 50 60 . . . . - 60598-1 (. 1.2.60). . - . () I. , ( ), - , 90 % 110 % , 60598-1 60598-2, , . . , 61347-2-13 , - , .2 . . - ( ). : 60081 . (IEC 60081,Double-capped fluorescent lamps Performance specifications) 60317-0-1:2008 . 0-1. . (IEC 60317-0-1:2008, Specifications forpart
4、icular types of winding wires Part 0: General requirements Section 1: Enamelled round copper wire)1 61347-12011 60384-14 . 14. . (IEC 60384-14, Fixed capacitors for use in electronic equipment Part 14:Sectional specification: Fixed capacitors for electromagnetic interference suppression and connecti
5、on to thesupply mains) 60417 , (IEC 60417, Graphical symbols for useon equipment) 60529:1989 , ( IP). 1 (1999)(IEC 60529:1998, Degrees of protection provided by enclosures (IP Code), Amendment 1 (1999) 60598-1:2008 . 1. (IEC 60598-1:2008, Luminaires Part 1: General requirement and tests) 60664-3 . 3
6、. , (IEC 60664-3, Insulation coordination for equipment within low-voltage systems Part 3: Use of coating,potting or moulding for protection against pollution) 60691:2002 . (IEC 60691:2002, Thermal-links Requirements and application guide) 60695-2-10 . 2-10. . (IEC 60695-2-10, Firehazard testing Par
7、t 2-10: Glowing/hot-wire based test methods Glow-wire apparatus and common testprocedure) 60695-11-5 . 11-5. . . , (IEC 60695-11-5, Fire hazard testing Part 11-5: Test flames Needle-flame test methods Apparatus,confirmatory test arrangement and guidance) 60730-2-3 . 2-3. (IEC 70730-2-3, Automatic el
8、ectrical controls for householdand similar use Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescentlamps) 60901 . (IEC 60901,Single-capped fluorescent lamps Performance specifications) 60921:2004 . - (IEC 60921:2004, Ballasts for tubular fluorescent lamps Per
9、formancerequirements) 60923:2005 . - ( ). (IEC 60923:2005, Auxiliaries for lamps Ballasts for discharge lamps (excluding tubular fluorescentlamps) Performance requirements) 60929:2011 . (IEC 60929:2011, AC-supplied electronic ballasts for tubularfluorescent lamps Performance requirements) 60990:1999
10、 (IEC 60990: 1999,Method of measurement of touch current and protective conductor current) 61189-2 , - . 2. (IEC 61189-2, Test methods for electrical materials, printed boards and other interconnection structures andassemblies Part 2: Test methods for materials for interconnection structures) 61249-
11、2 ( ) (IEC 61249-2 (all parts), Materials for printed boards and other interconnection structures) 61347-2 ( ) . 2. (IEC 61347-2 (all parts), Lamp controlgear Part 2: Particular requirements) 61347-2-8 . 2-8. - (IEC 61347-2-8, Lamp controlgear Part 2-8: Particularrequirements for ballasts for fluore
12、scent lamps)2 61347-12011 61347-2-9:2000 . 2-9. - ( ) (IEC 61347-2-9, Lampcontrolgear Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps),Amendments 1 (2003), 2 (2006) 4046-4:2002 , , . . 4. - (ISO 4046-4:2002, Paper, board, pulp and relatedterms Vocabula
13、ry Part 4: Paper and board grades and converted products)3 :3.1 (lamp controlgear): , , , - , -, , , , .3.1.1 (built-in lamp controlgear): , , , . . . . . .3.1.2 (independent lamp controlgear): - , , - . , - , , .3.1.3 (integral lamp controlgear): , .3.2 ; (ballast): , , , - . -, .3.2.1 , ; (d.c. supplied electronic ballast): , , , . , : , ( , ) - .3.2.2 ; (reference ballast): -