1、This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2009 by Navistar, Inc. AUGUST 2009 Page 1 of 1 NAVISTAR, INC. CEMS (CORPORATE ENGINEERING MATERIAL SPECIF

2、ICATION) NUMBER: CEMS GT-14A TITLE: Xylol Rubbing Test CURRENT ISSUE DATE: August 2009 WRITTEN/REVIEWED BY: Materials Engineering APPROVED BY: Materials Engineering SUPERSEDES ISSUE OF: August 2001 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This specification may involve h

3、azardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits prior to use. Change Noti

4、ce: Replaced “International Truck and Engine Corporation” with “Navistar, Inc.” per corporate directive. 1.0 SCOPE This is a method for evaluating the resistance of a dry paint film to aromatic hydrocarbons. 2.0 APPARATUS 2.1 Recirculating oven capable of maintaining 60 + 3C (140 + 5F) 2.2 Timer wit

5、h sweep second arm 3.0 MATERIAL 3.1 Xylene, industrial grade. 3.2 Gauze pads 3.3 Bonderite CD-10 or Bonderite 958 zinc phosphated steel panel, 100 x 150 mm (4 x 6 inches), available from Advanced Coatings Technologies, 273 Industrial Drive, Hillsdale, Michigan 49242. 4.0 PROCEDURE 4.1 Prepare a pane

6、l according to procedure specified for the appropriate grade enamel per Test Method GT-13, Panel Preparation. 4.2 Age panel at 60 + 3C (140 + 5F) for 72 hours and cool to 21 to 27C (70 to 80F). 4.3 Saturate gauze pad with xylene and rub a section of the painted surface with a circular motion ten rev

7、olutions in 10 + 2 seconds. Pressure exerted should be light to moderate and the radius of the arc will be 25 to 32 mm (1.00 to 1.25 inches). 4.4 Check immediately for color pickup on the gauze and softening of the surface. After a 30 minute recovery period, check for swelling, color change or softening. One or more of the above will constitute a failure. 5.0 REPORT Report pass or fail. Copyright Navistar International Corporation Provided by IHS under license with INTERNNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-