ITU-T E 424-1992 Test Calls - Telephone Network and ISDN Quality of Service Network Management and Traffic Engineering (Study Group II) 5 pp《测试呼叫 电话网络和综合业务服务网(ISDN)服务质量 网络管理和通信工程(研.pdf

上传人:吴艺期 文档编号:795167 上传时间:2019-02-02 格式:PDF 页数:5 大小:182.19KB
下载 相关 举报
ITU-T E 424-1992 Test Calls - Telephone Network and ISDN Quality of Service Network Management and Traffic Engineering (Study Group II) 5 pp《测试呼叫 电话网络和综合业务服务网(ISDN)服务质量 网络管理和通信工程(研.pdf_第1页
第1页 / 共5页
ITU-T E 424-1992 Test Calls - Telephone Network and ISDN Quality of Service Network Management and Traffic Engineering (Study Group II) 5 pp《测试呼叫 电话网络和综合业务服务网(ISDN)服务质量 网络管理和通信工程(研.pdf_第2页
第2页 / 共5页
ITU-T E 424-1992 Test Calls - Telephone Network and ISDN Quality of Service Network Management and Traffic Engineering (Study Group II) 5 pp《测试呼叫 电话网络和综合业务服务网(ISDN)服务质量 网络管理和通信工程(研.pdf_第3页
第3页 / 共5页
ITU-T E 424-1992 Test Calls - Telephone Network and ISDN Quality of Service Network Management and Traffic Engineering (Study Group II) 5 pp《测试呼叫 电话网络和综合业务服务网(ISDN)服务质量 网络管理和通信工程(研.pdf_第4页
第4页 / 共5页
ITU-T E 424-1992 Test Calls - Telephone Network and ISDN Quality of Service Network Management and Traffic Engineering (Study Group II) 5 pp《测试呼叫 电话网络和综合业务服务网(ISDN)服务质量 网络管理和通信工程(研.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、INTERNATIONAL TELECOMMUNICATION UNION CCITT THE INTERNATIONAL TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE TELEPHONE NETWORK AND ISDN QUALITY OF SERVICE NETWORK MANAGEMENT AND TRAFFIC ENGINEERING E.424 (1 0/92) TEST CALLS Recommendation E.424 CCITT RECflN*Em424 92 486259L 0576476 7T4 FOREWORD The

2、CCITT (the International Telegraph and Telephone Consultative Committee) is a perinanent organ of the Iiiteniational Telecomnunication Union (ITU). CCITT is responsible for studying technical, operating atid tariff questions and issuing Recommendations on them with a view to standardizing telecommun

3、ications on a worldwide basis. The Plenary Assembly of CCITT which meets every four years, establishes the topics for study and approves Recommendations prepared by its Study Groups. The approval of Recommendations by the members of CCITT between Plenary Assemblies is covered by the procedure laid d

4、own in CCITT Resolution No. 2 (Melbourne, 1988). Recommendation E.424 was revised by Study Group II ,and was approved under the Resolution No. 2 procedure on the 30th October 1992. CCIT NOTE In this Recommendation, the expression “Administration” is used for conciseness to indicate both a telecommun

5、ication adtninistration and a recognized private operating agency. l O ITU 1993 All rights reserved. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the ITU. CCIT

6、T RECMN*E-424 92 4862593 0576477 630 = Recommendation E.424 TEST CALLS (revised 1992) 1 (:eneral Test calls cruried out manually or automatically to assess the functioning of international circuits of connections are of four types: Typt I test ccill A test call conducted between two directly connect

7、ed international centres to verify that the transmission aiid signalling on nn international circuit of a given group are satisfactory. Typa 2 test cri11 A test call conducted between two international centres not directly connected to verify transit operational facilities of an intermediate interna

8、tional centre. Type 3 test cwll A test call from ai international centre to a subscriber type number in the national network of the distant country, generally as a result of a particular kind of fault. Siihsrriber-to-sirhscriber type test cdli) A subscriber-to-subscriber type test call is a test cal

9、l from a test equipment having the characteristics of aii average subscriber line in one national network to a similar equipment in the national network of a distant country. Test calls types I, 2, 3 and subscriber-to-subscriber test calls must not interfere with customer traffic. If, however, test

10、calls coiiuibuting a significant load on a part of a nehvork are to be made, prior advice should be given to the other Adrnitiistratioii(s) concerned. Types 1 aid 2 test calls for preventive maintenance should be conducted during light liad periods. Types 1 and 2 test cds should be conducted as and

11、when required for the investigation and clearance of faults. To aid the effectiveness of test calls type 3, the provision of a 1040 Hz to similar amwering device iii Type 3 test calls should be conducted only after adequate testing has been done by means of type 1 or 2 test udls and after the distan

12、t Administration has made the necess,q check in its national network. Type 3 test calls should he conducted during light load periods. In order to find faults in last-choice equipment, circuit multiplication equipment or in-circuit multiplexing equipment, it may be necessary for tests to be carried

13、out at the time when the traffic load approaches the full capacity of the route under test. The agreement of the distant network analysis point will be necessary before this test is cmied Out. Subscriber-to-subscriber type test cills cati be made by agreement of the network analysis point in the cou

14、ntries ccincenied. Norinally, unless there is a specific agreement between the Administrations concerned, subscriber- 1) verifying that there are no evident faults in the international switching centres involved that would cause the poor Quality of Service or subscriber complaint being investigated;

15、 2) verifying that type 1 or type 2 test crds have been made on the international circuits that might have heeii involved; national networks is recmnmended. to-subscriber type test calls would be considered for fault location after: Krciiiiiiieiiilatiuii M.1235 describes the use of automatic-to-subs

16、criber test calls in more detail. Recommendation E.424 (10/92) 1 CCITT RECMN*E*424 42 4862543 057b478 577 3) verifying that there are no evident faults in the national network from the outgoing exchange to the inteniational centre in the originating country; verifying that there are no evident fault

17、s in the national network in the distant country, froin the international centre to the called exchange. 4) When test calls are undertaken from the inteniational centre to a subscriber number to verify that there are no evident faults in the national network, such calis should be routed through the

18、international centre on the same path as a iionnal incorning international call. Using the test access facilities in the international centre could route calls via a different path thereby masking a fault. When subscriber-to-subscriber type test calls are made, the network analysis point in the two

19、countries i) the expected nature of the fault; ii)- international accounting agreements; iii) the need for making the test calls in the busy hour; iv) the possibility of causing or aggravating congestion at the time the calls are made. The responding equipmeiits used for subscriber-to-subscriber typ

20、e test calls could be those used for should consider such factors as: rnainteriance of the national network. 2 Results of test calls (See Table 1E.424.) 2 Recommendation E.424 (10/92) CCITT RECMNxE.424 92 W 4862591 057b479 403 = TABLE iE.424 Resiilts of test calls Intematinal outgoing exchange: . Ty

21、pe of test call Type la) Type 34 Circuit group: Type 24 semi-automatica) Sub-to-Sba) Semice automatica) Period from to Category 1. Satisfactory tests . 2. Signalling and charging faults . 2.1 Wrong number 2.2 No tone, no answer 2.3 Absence of a backward line signal . 2.4 Other faults . 3. Transmissi

22、on faults . 3.1 Conversation impossible 3.2 Call overamplified or underamplified 3.3 Noise . 3.4 Fading . 3.5 Crosstalk . 4. Congestion . 5. Other faults . Test carried out . Test procedure followed (apparatus used, destination of calls, etc.) Number Subtotal . . . . . . . , . Total , . . . Perccntage Subtotal . . . . . . . Total . . 100 a) Delete whichever is inapplicable. Recommendation E.424 (10192) 3

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 60811-602-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 602 Physical tests - Separation of oil in filling compounds (IEC 60811-602 .pdf DIN EN 60811-602-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 602 Physical tests - Separation of oil in filling compounds (IEC 60811-602 .pdf
  • DIN EN 60811-603-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 603 Physical tests - Measurement of total acid number of filling compounds .pdf DIN EN 60811-603-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 603 Physical tests - Measurement of total acid number of filling compounds .pdf
  • DIN EN 60811-604-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 604 Physical tests - Measurement of absence of corrosive components in fill.pdf DIN EN 60811-604-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 604 Physical tests - Measurement of absence of corrosive components in fill.pdf
  • DIN EN 60811-605-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 605 Physical tests - Measurement of carbon black and or mineral filler in p.pdf DIN EN 60811-605-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 605 Physical tests - Measurement of carbon black and or mineral filler in p.pdf
  • DIN EN 60811-606-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 606 Physical tests - Methods for determining the density (IEC 60811-606 201.pdf DIN EN 60811-606-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 606 Physical tests - Methods for determining the density (IEC 60811-606 201.pdf
  • DIN EN 60811-607-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 607 Physical tests - Test for the assessment of carbon black dispersion in .pdf DIN EN 60811-607-2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 607 Physical tests - Test for the assessment of carbon black dispersion in .pdf
  • DIN EN 60812-2006 Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) (IEC 60812 2006) German version EN 60812 2006《系统可靠性分析技术 失效模式和效.pdf DIN EN 60812-2006 Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) (IEC 60812 2006) German version EN 60812 2006《系统可靠性分析技术 失效模式和效.pdf
  • DIN EN 60819-1-2012 Non-cellulosic papers for electrical purposes - Part 1 Definitions and general requirements (IEC 60819-1 2009) German version EN 60819-1 2012《电工用非纤维素纸 第1部分 定义和一.pdf DIN EN 60819-1-2012 Non-cellulosic papers for electrical purposes - Part 1 Definitions and general requirements (IEC 60819-1 2009) German version EN 60819-1 2012《电工用非纤维素纸 第1部分 定义和一.pdf
  • DIN EN 60819-2-2002 Non-cellulosic papers for electrical purposes - Part 2 Methods of test (IEC 60819-2 2001) German version EN 60819-2 2001《电工用非纤维素纸 第2部分 试验方法》.pdf DIN EN 60819-2-2002 Non-cellulosic papers for electrical purposes - Part 2 Methods of test (IEC 60819-2 2001) German version EN 60819-2 2001《电工用非纤维素纸 第2部分 试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1